Emissions Monitoring Equipment In Peru
-
PremiumManufactured by ENVEAbased in FRANCE
Continuous, accurate and reliable measurement of total mercury emissions, even in very low concentrations and within complex matrices (SO2, NOx, HCl, etc.). With over 20 years experience, Mercury Instruments (part of ENVEA Group) were the first to develop mercury monitors and mercury analyzers using a dry thermocatalytic method instead of ...
-
PremiumManufactured by ENVEAbased in FRANCE
Beneficiary of over 20 years of experience in mercury measurement, the new SM-5 CEMS Hg analyzer is designed to provide extremely accurate and reliable continuous measurements of very low concentrations of Hg in flue gas emissions. The SM-5 features short response times, dynamic ranges and stable measurement under all ...
-
PremiumManufactured by ENVEAbased in FRANCE
Continuous, accurate and reliable measurement of total mercury emissions, even in very low concentrations and within complex matrices (SO2, NOx, HCl, etc.). With over 20 years experience, Mercury Instruments (part of ENVEA Group) were the first to develop mercury monitors and mercury analyzers using a dry thermocatalytic method instead of ...
-
PremiumManufactured by ENVEAbased in FRANCE
The Leak Locate 660 PLUS is a dust emission monitoring system incorporating a digital network and advanced graphics capability. It is designed for use in any processes where filter type arrestment plant are used, eg bag, ceramic and cartridge filters. The system comprises up to 32 networked sensors, a central control unit, user interface with ...
-
PremiumManufactured by ENVEAbased in FRANCE
The DM 170 is designed to comply with the TÜV suitability testing scheme to EN 15267 and for measuring dust concentrations in a wide range of industrial ...
-
PremiumManufactured by ENVEAbased in FRANCE
The QAL 181 dust analyzer is suitable for measuring particle emissions after both bagfilter and electrostatic precipitator arrestment plant. The monitor is suitable for measuring both low (0.1mg/m3) and high particulate concentration levels (300mg/m3). TÜV and MCERTS ...
-
PremiumManufactured by ENVEAbased in FRANCE
Using a proven flame ionisation detector (FID), the analyzer HC51M measures ambient air hydrocarbons (THC, CH4, nmHC) in the range 0-1000 ...
-
Manufactured by AMETEK Process Instrumentsbased in USA
The 914 is a built-to-order Continuous Emission Monitor (CEM) that includes all the components needed for a compliance monitoring and reporting project. The system uses dry extractive sampling techniques designed to meet government regulations for all types of compliance ...
-
PremiumManufactured by ENVEAbased in FRANCE
Standard Reference CLD method for low & ultra low NOx measurement, IR-GFC for CO, CO2, SO2, N2O, Nox, HF, HCl, TOC and O2 in a single analyzer. Fast and simultaneous measurements of up to 10 gases, available in 2 versions: NOx (CLD) and O2 (Paramagnetic) in 19’’ Rack or Tight box for low and ultra-low NOx monitoring. CO, CO2, ...
-
PremiumManufactured by ENVEAbased in FRANCE
Gas Sampling system for use in combination with low concentration analyzers (Ambient Air ...
-
PremiumManufactured by ENVEAbased in FRANCE
One single analyzer for the measurement of up to 50 parameters, to be selected according to the application. MCERTs certified. Based on the FTIR technology (Fourier Transform Infrared) for simultaneous measurement of: HCl, HF, NH3, NO, NO2, N2O, SO2, CO, CH4, TOC, H2O, CO2, ...
-
PremiumManufactured by ENVEAbased in FRANCE
The QAL 260 series is suitable for measuring dust concentrations in Combustion, Incineration and other industrial stacks and is compliant with EN 14181. Having a 0-15 mg/m³ certification range, the QAL 260 sensor can be used at low or high dust levels. Due to dynamic ranging, the sensor is also suitable for much higher dust levels found in Power, Cement and Metals smelting ...
-
PremiumManufactured by ENVEAbased in FRANCE
Offers excellent performance for multigas measurements in dry sampling, including HCl, HF, NO, NO2, N2O, SO2, CO, CH4, TOC, CO2 and O2 in process applications or for stack emission compliance. Multi-Gas NDIR-GFC analyzer (Non-Dispersive Infrared Gas Filter Correlation) measuring up to ten gases simultaneously, including Nitrogen ...
-
PremiumManufactured by ENVEAbased in FRANCE
Rack 3U monitor using the TDL extractive technology to measure online the NH3 pre and/or post catalyst: SCR (Selective Catalytic Reduction) or SNCR (Selective Non-Catalytic Reduction) ENVEA is offering Laser Gas Detection (LGD) modules with exceptional advantages and value for the customer. Tunable Diode Laser Spectrometry (TDLS), ...
-
PremiumManufactured by ENVEAbased in FRANCE
Ideal for mid-high to high concentrations or for sampling locations in hazardous areas. The flue gas is extracted, filtered & diluted with clean / dry air, by an in-stack dilution probe, before being sent to the analyzer. This technique lowers the flue gas dew point, keeping the sample temperature above it and at ambient temperature, in order to eliminate all condensation issues (water ...
-
PremiumManufactured by ENVEAbased in FRANCE
CLD based gas monitor offering superior performances for the measurement of NO, NO2 and NOx criteria pollutants in the range 0-1 ppm or 0-10 ppm. Optional NH3 monitoring. Eco-designed, reference air quality monitor, based on the chemiluminescence technology, the standard method for the measurement of nitrogen oxides (EN 14211). QAL1 ...
-
PremiumManufactured by ENVEAbased in FRANCE
paramagnetic sensor. The analyzer has been designed to meet the specific needs of on-site regulatory measurement providing superior mobility, robustness, accuracy and compliance. All this makes up for a unique gas emission monitor offering high productivity and low operational cost. ...
-
PremiumManufactured by ENVEAbased in FRANCE
The MIR 9000H is a multi-gas analyzer using the Gas Filters Correlation technology (GFC). With its hot measurement principle (180 °C on a hot and humid sample), the MIR 9000H is the perfect tool for the analysis of the main gas parameters in many applications, including DeNOx (SCR / SNCR) and the optimization of flue gas treatment ...
-
PremiumManufactured by ENVEAbased in FRANCE
The PCME STACKFLOW 400 is an advanced flue gas flow measurement system for continuous monitoring of releases from industrial sources complying with European monitoring standard EN 16911-2:2013 and ...
-
PremiumManufactured by ENVEAbased in FRANCE
), to reduce environmental impact and cost of reagents. To optimize this process, it is essential to use an emissions analysis system for simultaneous and continuous monitoring of NOx and ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you