EPA Method Equipment
-
PremiumManufactured by Apex Instruments, Inc.based in USA
The Apex Instruments PFAS Sampling System is based on the EPA Other Test Method 45 (OTM-45) and Other Test Method 50 (OTM-50) for the isokinetic collection of PFAS from stationary sources. PFAS stands for per- and polyfluoroalkyl chemicals, which are found in a wide range of consumer products and facilities. PFAS can accumulate in the body and ...
-
Manufactured by Xenosep Technologies LLCbased in USA
Extract Samples 5 Times Faster, Distill Samples 3 Times Faster, and Significantly Lower Cost Per Test... Step 1 Extract 1 L Sample 17 seconds is all it takes to filter a 40 mg/L* OPR and achieve 98% recovery. That’s 50 times faster than a typical single layer SPE filter with 89% recovery. In addition, triple layer Xenosep SPE Filters have 5 times the filtration capacity already built-in for ...
-
Distributed by Chrysalis Scientific Technologies Inc.based in CANADA
The Gas Sniper features PPM , %LEL or %Volume measurement capability to address a wide range of monitoring requirements. The Gas Sniper detects and monitors a wide range of standard gases including many toxic gases (refer to Gas Sensor Selection Table). In addition, the Gas Sniper’s ability to simultaneously detect up to ‘6’ gases provides users with the ability to configure ...
-
ShowcaseManufactured by J.U.M. Engineering GmbHbased in GERMANY
13526 (EU) and with EPA Method 25A and Method 503 ...
-
PremiumManufactured by Metrohm AGbased in SWITZERLAND
is well-suited to applications with a high ionic load but which require only relatively low resolution. Using the Metrosep A Supp 16 - 100/4.0 to determine bromate in water by means of the triiodide method (EPA 326, DIN EN ISO 11206) is another of its numerous ...
-
PremiumManufactured by LNI Swissgasbased in SWITZERLAND
The Sonimix 7050 is a simplified gas mixer based on the principle of gas stream through mass flow controllers (MFC) and mainly used to calibrate and linearize Gas Monitors. Built according to the ISO 6145/7 normalization, the Sonimix 7050 is totally compatible with the US EPA methods and can be easily linked with National Standards (NIST, ...
-
PremiumManufactured by AMS, Inc.based in USA
The ESS Lock N' LoadTM disposable soil core sampler is the easiest way to collect undisturbed, measured soil cores for field preservation techniques for EPA Method ...
-
PremiumManufactured by Tekran Instruments Corporationbased in CANADA
of providing a fully automated implementation of EPA Method 1631. This method is capable of measuring waters and digested solids with detection limits over 10X lower than ...
-
PremiumManufactured by AMS, Inc.based in USA
The ESS Core N' OneTM disposable soil core sampler is the easiest way to sample and transport 5 grams of undisturbed soil samples for US EPA Method 5035. CNO is both a soil collection and transport container. CNO capsule incorporates an extruding feature; no need for expensive tools. Threaded septa closure insures air tight seal. CNO ...
-
PremiumManufactured by Lumex Instrumentsbased in CANADA
analyzer RA-915M and PYRO-915+ attachment. Traps are specifically designed to comply with the US EPA Method 30B and PS-12B Performance ...
-
PremiumManufactured by Optical Scientific Inc. (OSi)based in USA
non-contacting cross-stack flow measurement of the process. The OFS uses our EPA Method 14 approved optical scintillation technology. The optical scintillation technique relies on advanced Digital Signal Processing (DSP) electronics to "see" and measure the movement of turbulence found in a gaseous flow stream to provide highly accurate, ...
-
PremiumManufactured by J.U.M. Engineering GmbHbased in GERMANY
accuracy and sensitivity. The 3-300A is fully identical to the VE7 and 3-200 and has been officially approved for that. TÜV approved and certified for 2. BImSchV. 13. BImSchV and 17. BImSchV and fully complies with QAL1, EN 12619, EN 13526 (EU) and with EPA Method 25A and Method 503 ...
-
PremiumManufactured by Apex Instruments, Inc.based in USA
Pre-programmed Method 5 Casio Calculator. The programmed isokinetic calculator serves as a replacement for the nomograph, or slide-rule calculator, to calculate isokinetic conditions for EPA Method 5 and EPA Method 5-type sampling. The calculator is developed to be accurate and simple to ...
-
PremiumManufactured by J.U.M. Engineering GmbHbased in GERMANY
, (Germany) and with EPA Method 25A and Method 503 (USA). It is ideally suited to be used in all stack emissions ...
-
ShowcaseManufactured by Cerex Monitoring Solutions, LLC.based in USA
Measurements: The UV Sentry is a parts per billion (ppb) to percent level chemical detection and quantification open-path UV-DOAS analyzer. It offers high-performing, time-resolved monitoring of a variety of regulated ...
-
PremiumManufactured by J.U.M. Engineering GmbHbased in GERMANY
of an industrial vent, from an internal combustion engine, or from any other emission containing hydrocarbons. The 3-900 fully complies with EN 12619, EN 13526, QAL 1 (EU), with 2. BImSchV, 13. BImSchV and 17. BImSchV, (Germany) and with EPA Method 25A and Method 503 (USA). It is ideally suited to be used in all stack emissions ...
-
PremiumManufactured by Optical Scientific Inc. (OSi)based in USA
model is equipped with Automatic Gain Control (AGC) to compensate for variations in opacity caused by particulate matter or moisture carried in the stack flow. The OFS uses our EPA Method 14 approved optical scintillation technology. The optical scintillation technique relies on advanced Digital Signal Processing (DSP) electronics to "see" and ...
-
PremiumManufactured by J.U.M. Engineering GmbHbased in GERMANY
any other emission containing hydrocarbons. The 3-500 is based on our time proven 300A FID platform of which we have sold thousands of analyzers. The 3-500 fully complies with EN 12619, EN 13526 (EU), with 2. BImSchV, 13. BImSchV and 17. BImSchV, (Germany) and with EPA Method 25A and Method 503 (USA). It can be used as a table top ...
-
PremiumManufactured by J.U.M. Engineering GmbHbased in GERMANY
. BImSchV and 17. BImSchV, (Germany) and with EPA Method 25A and Method 503 (USA). It is ideally suited to be used in all stack emissions ...
-
PremiumManufactured by J.U.M. Engineering GmbHbased in GERMANY
any other emission containing hydrocarbons. The 3-500 is built on our time proven 300A FID platform of which we have sold thousands of analyzers. The 3-600 fully complies with EN 12619, EN 13526, QAL 1 (EU), with 2. BImSchV, 13. BImSchV and 17. BImSchV, (Germany) and with EPA Method 25A and Method 503 (USA). It can be used as a table top ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you