Only show results available in Virginia? Ok

exhaust gas dilution equipment

  • Dilution System for Gas Detection Applications

    The Dilution System [flow diagram] operates by mixing the sample to be analyzed (the analyte) with diluent purified air or nitrogen. The optimal flow rates for both the analyte and diluent are determined based on the particular application, and are monitored and controlled at integral rotameters. The diluent is generally introduced from a nitrogen ...

    By Interscan Corporation based in Simi Valley, CALIFORNIA (USA).

  • Hydrokat

    Electrodeionisation (EDI) and electrolytic ozone generation are now widely used for water treatment since they require no chemicals. However, both of these processes generate hydrogen and, since mixtures of air and hydrogen with a wide range of relative concentrations are explosive, the exhaust gas must either be diluted sufficiently by means of ...

    By Aqua EPC L.L.C based in Dubai, UNITED ARAB EMIRATES.

  • Wet Ammonia Scrubbers

    Wet scrubbers remove pollutants by injecting liquid into the gas stream. Scrubbers built to remove particulates – such as dust scrubbers – the particulate is captured by the water droplets before it is discharged through the exhaust stack. Chemical scrubbers are different: the liquid in question causes a chemical reaction that strips the chemical ...

    By Pollution Systems based in The Woodlands, TEXAS (USA). from Wet Ammonia Scrubbers Product line

  • Tema - Packed Tower Scrubber

    Packed tower scrubbers are used to remove particulate and / or vapor contaminants from an exhaust gas stream by way of dilution or absorption. A packed tower is an efficient method of carrying out mass transfer between gas and liquid phases. Packed tower scrubbers incorporate packing media to facilitate intimate contact between a scrubbing liquid ...

    By TEMA Process B.V. based in Wapenveld, NETHERLANDS. from Packed Tower Scrubber Product line

  • Model 4000VM - Heated Vacuum Chemiluminescence

    The 4000VM relies on the heated vacuum chemilumenscence method of nitric oxide gas detection and has the capability to measure raw combustion exhaust gases. The 4000VM featrues a 191 degree C heated sampling system and filter which is easily removed from the rear panel for cleaning or replacement. This NO/ NOx gas analyzer also features a cooled ...

    By K2BW Environmental Equipment Company based in Willow Grove, PENNSYLVANIA (USA). from Heated Vacuum Chemiluminescence Product line

  • HORIBA - Model CVS-ONE Series - Constant Volume Sampler

    The CVS-ONE series is designed for the measurement of diluted emissions from vehicles and engines. The new integrated operating platform, HORIBA ONE PLATFORM is adopted for the CVS-ONE. The hardware has been significantly downsized from previous designs, reducing test cell footprint requirements. It introduces new functions and is more ...

    By HORIBA Europe GmbH based in Leichlingen, GERMANY. from Constant Volume Sampler Product line

  • Genius5 - Model pc - using filter and particulte counter

    This instrument was developed to measure dust in incineration plants and exhaust gas streams in concentration range 0.1 to 30 mg/m3. Combination of dust filter and particulate counter: Sampling System is based on EN 13284-1 Standard, using a d=47 mm planar filter and a Dilution cell, which uses a particulate counter. Planar filter has good ...

    By Genius5-Instruments GmbH based in Kottingbrunn, AUSTRIA.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you