gas monitoring system Equipment available in Senegal

Available in Senegal| Near Senegal
1758 Results found

We couldn't find any gas monitoring system equipment in Senegal

Here is a list of results available in Senegal

Current filtering criteria

You can remove a filter by clicking on the x
  • Keyword: gas monitoring system ×

  • Available in: Africa ×

  • Available in: Senegal ×


TAPI - Model T400 - UV Absorption O3 Analyzer

by Teledyne Advanced Pollution Instrumentation (TAPI)     based in San Diego, CALIFORNIA (USA)

The Model T400 UV Absorption analyzer uses a system based on the Beer-Lambert law for measuring low ranges of ozone in ambient air.


Land - Model CEMs - Continuous Emissions Monitoring System Backup

by AMETEK Land     based in Dronfield, UNITED KINGDOM

What happens to your emissions data when a CEMs undergoes routine maintenance or an unexpected breakdown occurs?. Simple, it continues to be captured with the LAND CEMs Back-up system. This system keeps data downtime to a minimum - and ensures that any possible restrictions on data availability as part of an operating permit are met. The CEMs ...

NEO Monitors - Model LaserGas™ Q NO - For Tuneable Laser Absorption Spectroscopy (TLAS)

by NEO Monitors AS     based in Skedsmokorset, NORWAY

NEO Monitors LaserGas™ Q NO is using Tuneable Laser Absorption Spectroscopy (TLAS) i.e a non-contact optical measurement method employing solid-state  laser sources. The sensor remains unaffected by contaminants corrosives and does not require regular maintenance. The absence of extractive conditioning systems  further ...

NEO Monitors - Model LaserGas™ II SP Compact - Standard Single Path Compact Monitor

by NEO Monitors AS     based in Skedsmokorset, NORWAY

Derived from the standard Single Path instrument, SP Compact Monitors are optimized for short distance measurement in the range 10 to 100 centimeters. The Monitors feature a focused laser beam, which enables the instrument to measure through very thin nozzles (< 10 mm diameter). For applications with continuous purge to prevent dust on the ...

HORIBA - Model GA-360E/F360E Series - Trace Gas Monitor

by HORIBA Europe GmbH     based in Leichlingen, GERMANY

The GA-360E/F360E Series is a line up of units that provide ultrahigh sensitive, highly accurate, continuous monitoring of trace amounts of impurities contained in gases (N2, O2, He, Ar, H2, and Air) used in the semiconductor manufacturing process. Utilizing a cross-modulation method, GA-360E/F360 Series units have no zero drift due to the ...

Air check - Model Ex - H2 Gas Monitoring System

by PureAire Monitoring Systems, Inc     based in Lake Zurich, ILLINOIS (USA)

The Air check Ex H2 Gas Monitoring System is a compact gas monitoring system that’s ideal for continuously monitoring toxic and corrosive gases in hazardous areas. The Air check Ex non-intrusive calibration allows sensor calibration in hazardous areas without area declassification. The only tool required is a small magnetic wand, designed to ...

Model GAS 404 - Channel Direct Gas Monitoring System

by Gas Alarm Systems Ltd     based in Knaresborough, UNITED KINGDOM

The GAS 404 has been designed with features that provide an effective response to the detection of gas hazards in a wide range of environments.

NEO Monitors - Model LaserGas™ R2P - Monitor for Combine Extractive Measurement

by NEO Monitors AS     based in Skedsmokorset, NORWAY

The LaserGas R2P Monitor employs a measurement cell concept to combine extractive measurement with a compact analyser design. The measurement path length will enhance the detection limit. Heated and non-heated cells path lengths are available. The R2P monitor is a turn-key instrument. During installation no other operations are required other than ...

NEO Monitors - Model LaserGas™ II SP - Single Path Monitor for In-Situ Measurement in Stacks

by NEO Monitors AS     based in Skedsmokorset, NORWAY

Single Path Monitors are designed for in-situ measurement in stacks, ducts, or reactors with typical path lengths in the range 0.5 to 20 meters. By-pass and extractive configurations are also possible. The monitors’ compact design comprises the transmitter unit with laser module; collimating optics, and main electronics and the receiver unit ...

Vertex M - Toxic Gas Monitoring System

by Honeywell Analytics     based in Hegnau, SWITZERLAND

Cost-effective, 8 to 24 point toxic gas monitoring system that adapts to the changing gas detection needs. Vertex M is one of the industry’s most flexible, advanced toxic gas monitoring systems offering parts per billion detection levels and physical evidence of a gas leak. Vertex M ensures productivity as well as life safety. Vertex M with ...


Model VCEM5100 - Flue Gas Flow Monitor

by Codel International Ltd     based in Bakewell, UNITED KINGDOM

The VCEM 5000/51000 represents the latest generation of CODEL’s uni ue flow monitors. These systems measure the velocity of stack gases using a highly accurate time of flight measurement that is derived from a cross correlation analysis of the infra-red emissions of the turbulent gas. Two robust infrared detectors are used for the prime ...

Manning - Model Air Alert 96d - Multichannel Gas Monitoring System

by Honeywell Analytics     based in Hegnau, SWITZERLAND

Acts as the nerve centre of a modular gas detection network by providing continuous monitoring of up to 96 sensors. The Manning AirAlert™ 96d multichannel gas monitoring system is designed for installation and operational simplicity for continuous monitoring and control of toxic gases, combustible gases and Oxygen hazards.

NEO Monitors - Model LaserGas™ II MP Cabinet - Multipass (MP) Cabinet Monitor

by NEO Monitors AS     based in Skedsmokorset, NORWAY

The LaserGas II Multipass (MP) Monitor employs a multipass (Herriott) cell concept to combine long measurement path lengths with a compact analyser design. The long path will enhance the detection limit. Thus, the MP is the analyser of choice for measurement of trace levels of gases, offline in a controlled environment. It is also applicable for ...

Sarad - Model A²M 4000 - Radioactivity and Gas Monitoring System

by Sarad GmbH     based in Dresden, GERMANY

Monitoring of potentially endangered areas by radioactivity (gamma/aerosols) as well as toxic and combustible gases. The unit contains a GPS receiver and a wireless network interface. This allows to implement a temporary safety network in next to no time.

GDS - Model COMBI - Direct/Addressable Gas Monitoring System

by GDS Technologies Ltd.     based in West Yorkshire, UNITED KINGDOM

The Combi has been designed to operate in the full range of environments from commercial premises through to heavy industrial applications which may require hazardous area sensing. Typical monitor locations are - public buildings, car parks, tunnels, breweries, boiler plant rooms, water treatment works, H&V control, manufacturing, process ...

MRU VARIOplus - Model EN ISO 16911-1/14789 - Portable Flue Gas Monitoring System

by MRU Messgeräte für Rauchgase und Umweltschutz GmbH     based in Neckarsulm, GERMANY

Suitable for measurements according to: EN ISO 16911-1: Stationary source emissions, manual and automatic determination of velocity and volume flow rate in ducts, manual reference method. EN 14789: Stationary source emissions, determination of volume concentration of oxygen, reference method paramagnetism.

Model RM-5000 series - Multi-channel Gas Monitoring System

by Riken Keiki Co. Ltd     based in Tokyo, JAPAN

Feature High level of visibility Compatible with RM-570A/580 series Bar meter and digital multi-indication Low power consumption Support RS-485 communication function.

Vertex - Multi-Point Toxic Gas Monitoring System

by Honeywell Analytics     based in Hegnau, SWITZERLAND

Up to 72 points of continuous gas detection. Start your Vertex™ System with as little as eight points. As your monitoring needs change, Vertex™ expands, offering you up to 72 points of continuous gas detection. Place your sampling points up to 400 feet (120 meters) from the system. There is a choice of universal analyser modules and/or ...


Gasmet - Engine Emissions Monitoring System (EEMS)

by Gasmet Technologies Oy     based in Helsinki, FINLAND

The Gasmet engine emissions monitoring system EEMS has been designed engine emissions monitoring which require for fast response time. A typical application for Gasmet EEMS consists of H2O, CO2, CO, N2O, NO, NO2, SO2, HCl, HF, NH3, CH4, C2H6, C3H8, and C2H4, but it can be e

INNOVA 3731 - SF6 Leak Detection System

by LumaSense Technologies, Inc.     based in Santa Clara, CALIFORNIA (USA)

Detecting and quantifying Sulfur Hexafluoride (SF6) leakages in the T&D and Power industry. The SF6 Leak Detection products from LumaSense offer an unmatched combination of performance and convenience. Based on the company’s Photoacoustic Spectroscopy (PAS) technology, they offers highly accurate, repeatable, and reliable quantitative gas analysis ...

Need help finding the right suppliers?

Let the XPRTs do the work for you