Mass Spectrometer Sample Equipment Available In Virginia
-
Manufactured by Hiden Analytical Ltd.based in UNITED KINGDOM
Sampling rate 12 μl/min. 24 μl/min option. Single or multi-capillary inlet option. 8 – 16 s response. Specially engineered to maintain a good ...
-
Manufactured by Hiden Analytical Ltd.based in UNITED KINGDOM
Sample pressure range 0.1 to 30 bar. Connects to standard QIC Inlet. Heated to ...
-
Manufactured by Hiden Analytical Ltd.based in UNITED KINGDOM
Sample pressure range 250 to 25 mbar. Operates to 200°C. Capillary length: 0.9 m. All stainless steel assembly. Swagelok 1/16” or 1/8” connection. Interchangeable with regular capillary in standard QIC systems. Corrosion resistant option ...
-
Manufactured by Hiden Analytical Ltd.based in UNITED KINGDOM
Sample pressure range less than 10-4 mbar to 1000 mbar. Flexible connection to process chamber. Automatic sample line ...
-
Manufactured by Hiden Analytical Ltd.based in UNITED KINGDOM
Sample pressure range 2 bar to 100 mbar. Operates to 200°C. Capillary length: 1.8 m (standard). Fast 300 ms sampling response. Sample consumption rates from 0.8 to 20 ml/min. Swagelok 1/16” or 1/8” connection. Corrosion resistant option available. Fast response 0.9 m capillary also available, with sample ...
-
Manufactured by Hiden Analytical Ltd.based in UNITED KINGDOM
Sample pressure range 10 to 1 mbar. Heated to 120°C. Capillary length: 0.3 m. Swagelok 1/8” connection. Rigid ...
-
Manufactured by Hiden Analytical Ltd.based in UNITED KINGDOM
For evolved gas studies. For OEMS, online electrochemical MS, where evolved gas flow is limited. Sample consumption rate of 250 μl/min. Operates to ...
-
Manufactured by Hiden Analytical Ltd.based in UNITED KINGDOM
For sampling ALD processes with options from 1-5 mbar or 5-50 mbar. Heated to 200°C. Air actuated heated (200°C) isolation ‘ALD’ valve included, not ...
-
Manufactured by Hiden Analytical Ltd.based in UNITED KINGDOM
A range of interfaces are available for TGA-MS evolved gas analysis. Specially designed to suit designated TGA instrument. Most manufacturers and models ...
-
Manufactured by Hiden Analytical Ltd.based in UNITED KINGDOM
Sample pressure range 2 bar to 100 mbar. Heated to 250°C (HT250) / 450°C (HT450). Sample consumption rates from 0.8 to 20 ml/min. Capillary length: 1.8 m. Swagelok 1/16” or 1/8” connection. Interchangeable with standard QIC Inlet. Corrosion resistant option available. Flexible and robust steel ...
-
Manufactured by Hiden Analytical Ltd.based in UNITED KINGDOM
For sampling from furnaces; interface from furnace to QIC. Includes heated filter assembly. Allows direct sample analysis to 1700°C. General design to suit most ...
-
Manufactured by Hiden Analytical Ltd.based in UNITED KINGDOM
Heated to 200°C. Provides low dead volume interface with ...
-
Manufactured by Hiden Analytical Ltd.based in UNITED KINGDOM
Probe sampler for the study of the chemical reactions that are catalysed by enzymes. All glass probe construction. ...
-
Manufactured by Hiden Analytical Ltd.based in UNITED KINGDOM
Probe sampler for in situ measurement of electrochemical products. Can be positioned at the electrodes of Redoxme™ cells and/or users’ own ...
-
Manufactured by Hiden Analytical Ltd.based in UNITED KINGDOM
A combined mass spectrometry inlet and electrochemical cell for real time differential mass resolved determination of gaseous or volatile electrochemical reactants, reaction intermediates and products while scanning electrochemical parameters. Allows static or dynamic electrolyte flow. Thin layer and dual layer ...
-
Manufactured by Hiden Analytical Ltd.based in UNITED KINGDOM
For analysis of sample with continuous flow, extracted sea or estuary water for ...
-
Manufactured by Hiden Analytical Ltd.based in UNITED KINGDOM
Flow through dissolved species probe inlet, with liquid flow connections. Larger surface area for fast and sensitive measurements. Integrated thermocouple for on-line sample temperature ...
-
Manufactured by Hiden Analytical Ltd.based in UNITED KINGDOM
For immersion and/or insertion in liquid or sludge samples, soil core sampling for ...
-
Manufactured by Hiden Analytical Ltd.based in UNITED KINGDOM
Flow through probe, low flow design for denitrification studies. Allows for water vapour removal using liquid nitrogen cold ...
-
Manufactured by Hiden Analytical Ltd.based in UNITED KINGDOM
Cuvette style sample cell for biofuel research. Removable cover for light sensitive ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you