Optical Non-Contact Measurement Equipment In Latin America
-
PremiumManufactured by Advanced Energy Industries, Inc.based in USA
Fast digital pyrometers with fiber optics for measurements on metals, ceramic, graphite, etc. Different optical heads available. Temperature ranges between 250 and 3500 °C. The Impac®50-LO plus and IGA 50-LO plus series comprise a range of highly precise, infrared measuring instruments, each equipped with fiber ...
-
PremiumManufactured by Advanced Energy Industries, Inc.based in USA
Digital Pyrometer with Focusable Optics for Non-Contact Temperature Measurement on various surfaces. Temperature ranges between 5 and 2000 °C. The digital Impac® IPE 140 pyrometers are renowned for their high accuracy and feature a range of focusable optics for extremely small spot sizes. These devices ...
-
PremiumManufactured by Advanced Energy Industries, Inc.based in USA
Fast digital pyrometer with focusable optics and integrated display for measurements on metals, ceramics, graphite, etc. Temperature ranges between 50 and 1800 °C. The Impac® IGA 140/23 series encompasses a collection of highly precise digital pyrometers designed for non-contact temperature measurement on ...
-
PremiumManufactured by Advanced Energy Industries, Inc.based in USA
Compact digital pyrometer with fiber optics for non-contact temperature measurements on metals, ceramics, graphite, etc. Different optical heads available. Temperature ranges between 85 and 1200 °C. The Impac® IGA 320/23-LO is a compact, short-wavelength pyrometer that easily integrates into production ...
-
PremiumManufactured by Advanced Energy Industries, Inc.based in USA
Digital pyrometer with fixed optics for non-contact temperature measurement of non-metallic surfaces or painted, coated or anodized metals between -32 and 900 °C. The Impac IN 5 plus series infrared thermometers are specially designed for non-contact temperature ...
-
PremiumManufactured by Zygo Corporation - AMETEK, Incbased in USA
The ZeGage Pro and ZeGage Pro HR 3D optical profilers provide non-contact measurement and characterization of micro- and nano-scale features of many types of surfaces, ensuring quality control and process monitoring in your manufacturing ...
-
PremiumManufactured by Advanced Energy Industries, Inc.based in USA
Fast digital pyrometer with focusable optics and integrated display for measurements on metals, ceramics, graphite, etc. Temperature ranges between 220 and 3500 °C. The Impac® IS 140 and IGA 140 series presents a range of digital, highly precise pyrometers, designed for non-contact temperature ...
-
PremiumManufactured by Zygo Corporation - AMETEK, Incbased in USA
High-precision non-contact absolute position measurement on up to 64 synchronized channels. ZYGO's ZPS system measures absolute position using ultra-compact optical sensors that are easily integrated into high-precision applications such as deformable mirrors and lens ...
-
Manufactured by NEO Monitors - a Nederman companybased in NORWAY
NEO Monitors LaserGas Q SO2 is using Tuneable Laser AbsorptionSpectroscopy (TLAS) i.e a non-contact optical measurement method employing solid-state laser sources. The sensor remains unaffected by contaminants corrosives and does not require regular maintenance. The absence of extractive conditioning systems further improves ...
-
Manufactured by NEO Monitors - a Nederman companybased in NORWAY
NEO Monitors LaserGas is using Tunable Laser Absorption Spectroscopy (TLAS) i.e. a non-contact optical measurement method employing solid-state laser sources. The portable analyzer is compact, lightweight, and battery powered for HF measurement on the spot. With onboard pump and connections for Teflon tubing the ...
-
Manufactured by NEO Monitors - a Nederman companybased in NORWAY
NEO Monitors LaserGas is using Tuneable Laser Absorption Spectroscopy (TLAS) i.e. a non-contact optical measurement method employing solid-state laser sources. Therefore, the sensor remains unaffected by contaminants and corrosives and does not require regular maintenance. The laser beam is coupled into a ...
-
Manufactured by NEO Monitors - a Nederman companybased in NORWAY
NEO Monitors LaserGas Q NO is using Tuneable Laser Absorption Spectroscopy (TLAS) i.e a non-contact optical measurement method employing solid-state laser sources. The sensor remains unaffected by contaminants corrosives and does not require regular maintenance. The absence of extractive conditioning systems further improves ...
-
Manufactured by NEO Monitors - a Nederman companybased in NORWAY
NEO Monitors LaserGas Q NO2 is using Tuneable Laser AbsorptionSpectroscopy(TLAS) i.e a non-contact optical measurement method employing solid-state laser sources. The sensor remains unaffected by contaminants corrosives and does not require regular maintenance. The absence of extractive conditioning systems further improves ...
-
Manufactured by NEO Monitors - a Nederman companybased in NORWAY
NEO Monitors LaserGas Q CF4 is using Tuneable Laser AbsorptionSpectroscopy (TLAS) i.e a non-contact optical measurement method employing solid-state laser sources. The sensor remains unaffected by contaminants corrosives and does not require regular maintenance. The absence of extractive conditioning systems further improves ...
-
Manufactured by NEO Monitors - a Nederman companybased in NORWAY
NEO Monitors LaserGas is using Tuneable Laser Absorption Spectroscopy (TLAS) i.e a non-contact optical measurement method employing solid-state laser sources. The sensor remains unaffected by contaminants corrosives and does not require regular maintenance. The absence of extractive conditioning systems further improves ...
-
Manufactured by NEO Monitors - a Nederman companybased in NORWAY
NEO Monitors LaserGas Q SO2 (QCL edition) is using Tuneable Laser Absorption Spectroscopy (TLAS) i.e a non-contact optical measurement method employing solid-state laser sources. The sensor remains unaffected by contaminants corrosives and does not require regular maintenance. The absence of extractive conditioning systems ...
-
Manufactured by NEO Monitors - a Nederman companybased in NORWAY
NEO Monitors LaserGas is using Tuneable Laser Absorption Spectroscopy (TLAS) i.e. a non-contact optical measurement method employing solid-state laser sources. Therefore, the sensor remains unaffected by contaminants and corrosives and does not require regular maintenance. The laser beam is coupled into a Herriott cell, where it ...
-
Manufactured by NEO Monitors - a Nederman companybased in NORWAY
NEO Monitors LaserGas is using Tuneable Laser Absorption Spectroscopy (TLAS) i.e a non-contact optical measurement method employing solid-state laser sources. The sensor remains unaffected by contaminants and corrosives and does not require regular maintenance. The absence of extractive conditioning systems further improves ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you