ENVEA - Model PCME LEAK LOCATE 320 - Filter Damage and Leak Monitoring
Electrodynamic filter damage and leakage monitoring of industrial multi chamber filter systems: proactive multi chamber filter monitoring, identification of upcoming filter damages, identification of the filter chamber affected by filter breakage, reduction of material-, downtime- and maintenance costs, flue-gas temperatures up to 150 °C (optional 250 °C), for dry applications, 4 sensors inclusive, expandable up to 32 sensors, digital inputs and outputs, external connections: USB 2.0 (type A), ethernet (RJ45/100 Mb/s).
Use
LEAK LOCATE 320 serves primarily to detect filter damages or incoming filter breaks at an early stage.
The key advantage of the LEAK LOCATE 320 system is the ability to locate the filter selection where the damage occurred.
Further features with LEAK LOCATE 320:
- advance warning at degradation of the filter
- significant savings in time and costs of maintenance
- to reduce probability of large emission incidents
Function
LEAK LOCATE 320 uses the electrodynamic measurement principle. If the dust to be measured is constant, then the generated measuring signal is proportional to the dust concentration, even if there are dust deposits on the measuring probe. Experience shows that the measuring method provides very exact results with little required maintenance.
A complete measuring system consists of these components:
- Welded casing to serve as a sensor receptacle
- LEAK LOCATE 320-sensor
Technical Data
Sensor
- Ambient Air Temperature: -20 ... +50 °C
- Stack Gas Temperature: 125 °C standard or 250° C option
- Stack Connection: 1½ BSPT, ½ BSPP, NSPM, NPT
- Enclosure Rating: IP 65
- Rod Length: 100 mm to 1000 mm
- Air Purge Connection: ½ inch BSPP
- ½ inch NPSM
- 1½ inch BSPT or NPT
- Power Requirements: 24 V DC (from PLUS-Controller)
- Sensor probe check: Automatically (optional)
PLUS Controller Data
- Number of sensors: 4 up to 32 sensors
- Ambient Air Temperature: -20 ... +45 °C
- Power Requirements: 100 ... 240 V AC, 1 A
- Data-Logs: Impulse (4 hours @ 1 s for 4 sensors)
- Ethernet: ModBus TCP
- Outputs (standard): 1 x RS 485 (ModBus RTU)
- 4 Relais (2 A @ 250 V, user configurable)