Designed to satisfy the exacting parameters of infrared focal plane array detectors, thermal imaging and forward looking infrared (FLIR) systems testing in static and moving scene applications, LumaSense’s M345X6-LC Series blackbody calibration sources combine fast slew rates, high emissivity, and unchallenged stability and uniformity. As part of an extensive range of general purpose and primary standards for testing and calibrating a wide variety of IR devices, the M345X6-LC Series embodies the accumulated expertise of almost 30 years of specialization in this discipline.

The M345X6-LC Series Blackbody Sources are liquid cooled and heated by precision thermoelectric modules (Peltier method) and are available in absolute or differential configurations. The two piece system is comprised of 19 inch rack mount controller and a separate emitter source enclosure.

The source is available in emitter size of 6x6 inch (152 x 152 mm) and in a standard temperature range of -40 °C to 100 °C (-40 to 212 °F).

  • High emissivity and uniformity
  • Excellent extremely low temperature calibration 
  • Large aperture sizes 
  • High accuracy, high resolution 
  • Manufactured and tested to meet rigid quality control standards

  • Infrared Temperature Sensors
  • Infrared Thermal Imaging Systems
  • Spectrographic Analyzers
  • Radiometers
  • Flux Meters

  • Temperature Range: -40 to 100 °C (-40 to 212 °F)
  • Temperature Uncertainty: 100 mK
  • Temperature Uncertainty
  • (Thermometric calibration): ±0.05 °C
  • Display Accuracy vs. NIST Calibration: ±0.05 °C at calibration points
  • Temperature Resolution: 0.01 °C
  • Short term stability: 0.02 °C per 8 hours period with no external air breezes
  • Source Non-Uniformity: ±0.2 °C (excluding 10% Border Area) up to 50 °C
  • Heated Emitter Shape: Thermally uniform plate
  • Exit Aperture: 152 x 152 mm (6” x 6”)
  • Emissivity(thermometric calibration): @ 8-15 μm: 0.9756 +/-0.0039 @ 3-5 μm: 0.9713 +/-0.0049
  • Standard Calibration Method: Thermo
  • Slew Rate to 1 °C Stability: 15 minutes maximum to -40 °C with chiller set at 0 °C
  • Slew Rate to 0.1 °C Stability: 15 minutes maximum for entire range travel
  • Temperature Sensor: Precision platinum RTD 1/3 DIN
  • Method of Control: Digital PID controller
  • Power Requirements: 115 VAC ±10% 60Hz
  • OPTIONAL: 230 VAC ±10% 50Hz, 1200VA maximum for blackbody only
  • POWER REQUIREMENTS MUST BE SPECIFIED AT TIME OF ORDER.
  • Warm-up Time: 15 min (-40 °C)
  • Operating Ambient Temperature: 20 °C to 30 °C
  • Dimensions (H x W x D): Controller module: 178 mm x 483 mm x 593 mm (7” x 19” x 23”)