- Model S TAF16 - High temperature TC Thermometer

From

0

Applicable for cement production, steel treatment, incinerators and fluidized bed furnaces. Measuring points with extremely high process temperatures require these special thermometers with ceramic or metal thermowells as well as thermocouples made from special metals, such as platinum and rhodium. The thermowell made from special materials protects from mechanical and chemical damages in the process and increases the life span of the used sensors. This leads to: Cost savings for maintenance of the measuring point, quality improvements of the products and increased plant safety.

  • Long lifetime by usage of innovative thermowell materials with increased wear and chemical resistance

  • Long term stable measurement due to sensor protection with non-porous materials

  • Flexible product selection by modular design

  • Optimized life cycle costs by means of replaceable spare parts

  • Applicable for cement production, steel treatment, incinerators and fluidized bed furnaces. The TAF16 contains a single or double TC insert and a metal or ceramic protection tube.

  • Process temperatures: up to +1700 °C (+3092 °F)

  • Measuring Principle: Thermocouple
  • Characteristic / Application:
    • metric style
    • modular temperature assembly
    • high temperature probe (furnace)
    • incl. thermowell / protection tube (metal)
  • Terminal head:
    • TA20A - aluminium - cover with screws
    • TA20D - aluminium - hinged cover high
    • TA30A - E+H, aluminium - cover low - w/o. display
    • TA30D - E+H, aluminium - cover high
    • DIN A - aluminum
  • Thermowell / protection tube:
    • welded protection tube
    • ceramic protection tube
  • Insert / probe:
    • mineral insulated (MI), flexible
    • ceramic capilarry, rigid
  • Outer diameter protection tube:
    • 14,0 mm (0,55')
    • 15,0 mm (0,59')
    • 17,2 mm (0,68')
    • 18,0 mm (0,71')
    • 21,3 mm (0,84')
    • 22,0 mm (0,87')
    • 26,7 mm (1,05')
    • 28,0 mm (1,10')
  • Max. immersion length on request: up to 4.525,00 mm (178,15'')
  • Material protection tube/ thermowell:
    • 1.4401 (316)
    • 1.4749 (~446)
    • 1.4841 (310)
    • Alloy 600 (2.4816)
    • Alloy 601 (2.4851)
    • Incoloy 800HT (1.4959)
    • Kanthal AF
    • Kanthal Super
    • NiCo
    • Siliciumnitrid(SiN)
  • Process connection:
    • compression fitting:
    • G1/2'
    • G3/4'
    • G1'
    • G11/4'
    • G11/2'
    • adjustable Flange
  • Tip shape: straight
  • Operating temperature range:
    • Type K:
    • -40 C ...1.100 C
    • (-40 F ...2.012 F)
    • Type J:
    • -40 C ...750 C
    • (-40 F ...1.382 F)
    • Type N:
    • -40 C ...1.150 C
    • (-40 F ...2102 F)
    • Type S:
    • 0 C ...1.400 C
    • (32 F ...2.552 F)
  • Max. process pressure (static): at 20 °C: 1 bar (15 psi)
  • Accuracy: class 2 acc. to IEC 60584
  • Integration head transmitter: yes (4 … 20 mA; HART; PROFIBUS PA; FOUNDATION FIELDBUS)
  • Certification: SIL (transmitter only)

Customer reviews

No reviews were found for Omnigrad - Model S TAF16 - High temperature TC Thermometer. Be the first to review!