The system is designed to control emissions (>99% SO2 and particulate removal) from two new 60,000-lb/hr dual fuel boilers, the system was designed and built to facilitate the dual fuel and also heat recovery. The flue gases from the two boilers are ducted to heat exchangers located on the mezzanine floor at the rear of the boilers. The flue gases pass down through the exchangers to the scrubber, which is located between the boilers. Flue gases exit the top of the scrubber pass through a re-heater before being discharged to the chimney. Water from the economizers and scrubber circuit was used to pre-heat boiler feed water. The complete installation was carried out whilst the existing boilers were in operation.
-