OTT HydroMet - Model OTT PLS-C - Pressure Probe with Conductivity Measurement Cell
From Water Level
The OTT PLS-C measures water conductivity, level, and temperature in both surface and groundwater applications with a robust ceramic pressure cell and 4-electrode conductivity cell. Its extremely low power consumption makes it ideal for long-term deployment, particularly at solar powered measuring stations for ground-and surface waters.
Product Highlights
- Application: Surface water, Groundwater
- Measurement technology: Vented pressure cell and 4-electrode graphite conductivity cell
- Parameters measured: Water level, Pressure, Conductivity, Temperature
- Product Highlights: Water level, temperature, and conductivity measurement - for use with external data logger
- Internal data logger: No
- Interface: SDI-12 or RS-485 (using SDI-12)
Advantages:
Outputs for conductivity include specific conductivity, salinity, and total dissolved solids
- The robust ceramic pressure cell offers industry-leading accuracy and does not deform over time like membrane technology, providing long-term measurement stability
- Rugged design: Ceramic pressure cell resistant to physical force (4 x burst pressure) and enclosure made of high-quality saltwater resistant steel for use in coastal environments
- Vented pressure probe, automatically compensates for changes in barometric pressure
- Robust cable with Kevlar core for length stabilization and capillary tube for venting
- Built-in microcontroller – compensates for temperature effects and applies correction values for gravitational acceleration or water density
- Simple setup and connection to external dataloggers using SDI-12
Example of Use
Water level, temperature, and conductivity measurement of:
- Groundwater wells
- Streams, rivers, channels, and canals
- Reservoirs, lakes, and wetlands
Ideal for monitoring:
- Continuous monitoring networks
- Short-term or long-term projects
- Salt water intrusion
- Aquifer storage and recovery
- Estuaries and wetlands
Technical Data
- Output parameters: Water level/pressure, temperature, specific conductivity, salinity, TDS
- Water level measurement (pressure):
- Pressure sensor: ceramic, temperature-compensated
- Measuring range: 0 ... 4 m, 0 ... 10 m, 0 ... 20 m, 0 ... 40 m, 0 ... 100 m water col.
- Resolution: 0.001 m; 0.1 cm; 0.01 ft; 0.1 mbar; 0.001 psi
- Accuracy (linearity + hysteresis): ≤ ± 0.05 % FS
- Long-term stability (linearity + hysteresis): ≤ ± 0.1 %/a FS
- Zerodrift: ≤ ± 0.1 % FS
- Pressure sensor capability to withstand overloads without permanent mechanical damage: ≥ 4 x measuring range
- Temperature-compensated operating range: -5 °C ... +45 °C (ice free)
- Units: m, cm, ft, mbar, psi
- Temperature measurement:
- Sensor: NTC
- Measuring range: -25 °C ... +70 °C (ice free)
- Calibrated range: +5 °C ... 45 °C
- Resolution: 0.01 °C
- Accuracy: ±0.1 °C
- Units: °C, °F
- Conductivity measurement:
- Sensor: 4 graphite electrodes
- Calibrated range: +5 °C ... 45 °C
- Measuring range 5 ... 2.000 µS/cm:
- Resolution: 1µS/cm
- Accuracy: ±1 µS/cm or ± 0.5 % of measured value (whichever is higher)
- Unit: µS/cm
- Measuring range 0.1 ... 100 mS/cm:
- Resolution: 0.01 mS/cm
- Accuracy: ± 0.01 mS/cm or ±1.5 % of measured value (whichever is higher)
- Unit: mS/cm
- Options:
- Temperature compensation, conductivity: freshwater, saltwater, standard method 2510, ISO 7888/EN27888
- Salinity calculation: Standard method or USGS 2311
- Electrical data:
- Supply voltage: 6 ... 27 V DC, typically 12/24 V DC
- Power consumption:
- SDI-12 sleep-mode: <30 µAV
- SDI-12 active-mode: <32 mA
- Interfaces: SDI-12, RS-485 (SDI-12 protocol)
- Mechanical data:
- Dimensions:
- Probe (Ø x h): 317 mm x 22 mm
- Cable length: SDI-12: 1 ... 100 m
- RS-485: 1 ... 1000 m
- Material:
- Housing material probe: POM, stainless steel
- (DIN 1.4539, 904 L ), resistant to sea water
- Cable jacket: PUR
- Weight:
- Probe: approx. 0.43 kg
- Probe cable: approx. 82 g/m
- Ambient conditions:
- Storage temperature: - 40 °C ... + 85 °C
- Type of protection: Probe: IP 68
- EMC limits: EG 2004/108/EG, EN 61326-1:2013
Customer reviews
No reviews were found for OTT HydroMet - Model OTT PLS-C - Pressure Probe with Conductivity Measurement Cell. Be the first to review!