Polaris - Model NMHC Docking Station - Portable TOC Analyser for Stack Emissions
From Stack Emission
POLARIS Docking Station SE – NMHC, perfectly integrated non-methane analysis. POLARIS Docking Station SE - NMHC s an external catalyst for the automatic analysis of Methane / NMHC. POLARIS FID SE controls the Docking Station to measure sequentially total hydrocarbons and/or methane only. Automatically it calculates the difference between them reporting the NMHC value. The Docking Station also powers POLARIS FID SE and heated lines. Optional internal temperature controller for the heated line, range 80°C - 200°C. Docking station is developed and tested according to the performance criteria of the EN25140:2010 for methane and not-methane analysis.
Product Details
Polaris FID SE, The Portable Fid for Stack Emissions: Lightweight, Compact, Safe and Smart
Polaris FID Smart Edition (SE) analyser is the evolution of the bestseller POLARIS FID, realized by Pollution Analytical Equipment. It is an on-site monitor for the detection of total organic carbon (TOC) in compliance with EN12619:2013 and EPA Method 25A. It is a fully portable instrument because it incorporates everything needed for the analysis; for that reason it is useful for environmental screening as well. POLARIS FID SE is Smart thanks to Bluetooth Connection and the designed APP to view real time data and graphs for any Android smart device.
Polaris FID SE Runs With Batteries Thanks to the Exclusive Design With Low Power Consumption
The miniaturization of the flame ionization detector (FID) and heated volumetric sampling system result in outstanding energy savings and thus allows the use of built-in rechargeable batteries. It also ensures the highest accuracy and repeatability of sequences of analysis.
Polaris FID SE is built to resist to the most difficult operating conditions
The instrument is designed to be resistant to samples with high temperature and humidity: this is a typical working condition with hot samples during stack monitoring.
The detector manifold, the sampling lines and all the valves are integrated into a single block and uniformly heated, in order to eliminate all possible cold spots and avoiding local sample condensation.
Polaris FID SE is Compact, Lightweight and Ergonomic for Easy Use
The instrument incorporates everything you need for analysis: batteries, hydrogen storage cartridge, pump and Activated Charcoal filter for the flame air, span gas cylinder for the calibration and technical air cylinder for high accuracy and precision. The sample inlet, with double filter, is compatible with all sampling lines on the market. It is equipped with comfortable shoulder strap for field use.
Description
POLARIS Docking Station SE - NMHC:
External Catalyst for automatic Methane/NMHCs analysis. POLARIS FID SE controls the Docking Station to measure
sequentially total hydrocarbons and/or methane only. Automatically it calculates the difference between them
reporting the NMHC value. The Docking Station also powers POLARIS FID SE and heated lines. Optional internal
temperature controller for the heated line, range 80°C –200°C. Docking station is developed and tested according to the performance criteria of the EN25140:2010 for methane and not-methane analysis.
Applications:
- On-site analysis of TOC (Total Organic Carbon) in Stack Emissions, in compliance with EN12619:2013 and EPA Method 25A
- Methane/NMHC Automatic analysis in compliance with EN25140:2010
- Environmental screening
Key Features:
- Rechargeable battery operations
fully portable - Integrated hydrogen cartridge
safe and compact - Zero Air and Span Gas integrated into the chassis
ergonomic and lightweight - Heated volumetric sampling system
accurate and precise - Alphanumeric display and USB port for uploading methods and downloading data analysis
easy and advanced - Docking station for Methane/NMHC and optional controller for heated lines
effective and flexible - TÜV Approval
certified and guaranteed - Wireless Bluetooth computer connection and Management software
fast and friendly - Designed APP for Android smart device
real-time data close at hand
Specifications
Polaris FID SE – Smart Edition Specifications:
- Size and Weight: 355(W) x 155(H) x 426(D) mm, 10 Kg (with batteries 13,4 Kg)
- Power Supply: External Power Adapter 110 ÷ 240VAC – 24VDC, 200W; 2 NMH batteries 9Ah (running-time roughly 2h @ 180°C detector)
- Transportation Information: UN 3496, Class 9 with Special Provision A199
- Sampling: Heated head system
- Environmental Operating Ranges: 0°C < T < +55°C - 0% < RH < 95%
- Max detector body temperature: 195°C
- Max temperature Sample Inlet: 185°C
- Materials in contact with the sample: Steel AISI316 and high performance polymers
- Sample flow: Approximately 800 ml/min
- Sample pressure: atm ± 100 mbar
- Measuring Range: 0-20/50/150/500/5.000/10.000/100.000 mgC/Nm3 (other on request) 0-10/100/1.000/5.000/50.000 ppm relative to Propane
- Accuracy: 1% of the F.S. or 0,4 mgC/Nm3 , whichever is greater (0,25 ppm as Propane)
- Setting Methods and Data Storage: Upload/Download Methods via USB; Internal Flash Memory data storage (30 days of continuous measurements)
- Interfaces: USB (download/upload methods and download data); Bluetooth (computer connection with provided software for real time data acquisition and designed APP for any Android smart device)
- Flame management: Electronic, with diagnostic and ‘flame off’ visual alarm, automatic system to restart the flame
- Hydrogen storage cartridge: Metal hydrides technology (running-time about 20 hours); rechargeable via external source of hydrogen under moderate pressure; transportation Information: no transport restriction (UN 3479)
- Zero Air: 1L Cylinder (non-rechargeable): technical air @ 12bar / 20°C (running time approximately 10h); Quick connectors for external Zero Air cylinder; Transportation Information: UN 1956, Hazard Class Number 2.2 (Non-Flammable Gas)
- Span Gas: 1L Cylinder (non-rechargeable): propane in air @ 12bar / 20°C (Concentration of total carbon equivalent : 16/40/120/320mg/Nm3); other configurations on request; quick connectors for external Span Gas cylinder
- Transportation Information: UN 1956, Hazard Class Number 2.2 (Non-Flammable Gas)
- Compliance and Certifications: Compliance: EN12619:2013. Certification: TUV Rheinland (ID 000039773) according to MCERTS performance standards; EN12619:1999, EN13526:2002; Quality Management System in conformity with EN15267-2 and ISO9001:2015
NMHC Docking Stations - Specifications
- Dimension and Weight: 330 (W) x 110 (H) x 330 (D) mm, 7 Kg
- Power Supply: 110 – 240VAC
- Automatic measurement: Methane, Carbon, total organic, NMHC (calculated)
- Optional: Temperature Controller (80-200°C) and sampling lines power supply
- Compliance: EN ISO25140:2010