Pulsar Measurement - Model MicroFlow - Non-contacting Microwave Liquid Velocity Sensor
MicroFlow delivers accurate, repeatable velocity measurement of liquid flow, either as a stand-alone device or as part of a complete measurement system. MicroFlow builds on Pulsar's award-winning pipe flow technology and world-leading open channel flow measurement systems.
MicroFlow can be installed as a stand-alone veloci...
MicroFlow can be installed as a stand-alone velocity sensor delivering data via RS485 Modbus or integrated within a complete system when combined with FlowCERT or Ultimate controller and dB series transducer.
Velocity x area calculation using MicroFlow provides a cost-effective flow measurement option compared to the installation of a primary measurement device such as a flume and provides a viable alternative where the hydraulics of the site do not allow for a restriction in the channel.
Features:
- Non-contacting
- Cost-effective
- Lightweight, compact design
- Minimal installation costs
- No interruption to service
- Maintenance-free
- RS485 Modbus
- IP68
Applications:
- Liquid Velocity Measurement
- Open Channel Flow
- Irrigation Channels
- Rivers & Canals
Technical Specifications:
- PHYSICAL
- Sensor body material: : Valox 357
- Mounting connection: : Mounting bracket with 45º bend (optional)
- Sensor body dimensions: : Diameter 86mm x Height 156mm (D 3.38in x H 6.14in)
- Sensor weight: : Nominal 1kg (2.2lbs)
- Transducer cable extensions: : Maximum 100m (328ft)
- ENVIRONMENTAL:
- Enclosure protection: : IP68
- Max. and Min. temperature: : -20ºC to +70ºC (-4ºF to +158ºF)
- Flammable atmosphere approval: : Safe area. (Hazardous area pending)
- APPROVALS:
- CE approval: : Complies with BS EN61326-1:2013 for emissions and immunity
- RADAR approvals: : EN 300-440-1
- EN 300-440-2
- FCC 15.245
- PERFORMANCE:
- Operating voltage: : 10-28Vdc
- Velocity range: : 0.2 - 6m/s
- Accuracy: : The greater of ±0.5% or 0.03m/s
- Optimum installation: : 45º optimum and mounted in the centre line of the channel with a clear uninterrupted view of the liquid surface
- Level measurement: : Compatible with up to dB6 transducer
- RADAR: : K Band (ISM)
- Transmitter power: : <15dBm
- Beam width: : 20º inclusive
- OUTPUTS:
- Communication: : RS485 and Modbus RTU - integrates with FlowCERT and Ultimate controller
- PROGRAMMING:
- PC Programming: : Via RS485 Modbus
- Programming security: : Via passcode
- Programming data integrity: : Via non-volatile memory
- PC setup and monitoring software: : MicroFlow PC
- SUPPLY:
- Power consumption: : 0.5W maximum