Quantum 3 is a fully-featured pump controller, using Pulsar's unique non-contacting ultrasonic technology including DATEM digital echo discrimination to provide sophisticated level management. Quantum 3 can be programmed to provide an alarm based on the time remaining before the station or well spills over. Vital for utilities who face the risk of prosecution if a station pollutes the local environment. Quantum 3 adds the ability to interface with up to four Flow Pulse non-invasive flow monitors, so all flow-rate based alarms and control is based on measured rather than calculated flow.
Features
- Can assign a Flow Pulse to either a pump, a main outlet or stand-alone measurement
- 24VDC output supply capable of supplying 4 Flow Pulse units
- 'Burst and Block' now based on real flow
- Auxiliary display can now cycle through each Flow Pulse and display real flow
- Totaliser sums real throughput rather than deriving from level measurement
- Has universal power supply input of 22-28 VDC and 85-264 Vac
- Storm detection alarm
- NRV leakage alarm
- Time to spill calculation
- Automatically resets tripped pumps
- Easy prompt led set up
- RS485 Modbus and Profibus DP V0 and V1 options
- Pump efficiency alarm function
- Peak power tariff avoidance
Applications
- Pump Control
- Time to spill warning requirements
- Reduction in power cost requirements
- Pump monitoring and control
- Water and waste water
Details
PHYSICAL
- Weight : Nominal 1.3kg (2.9lbs)
- Case material : Stainless steel and polycarbonate, flame resistant to UL94 V0
- Transducer cable requirements : Twin screened
- Maximum separation : 1000m (3280ft)
- Fascia mount : 200 x 112mm (7.87 x 4.41in) front, 165 x 105mm (6.49 x 4.13in) cut-out
OPTIONS:
- Digital communications : RS485 Modbus or Profibus DP V0 or V1
ENVIRONMENTAL:
- IP rating fascia mount : IP64
- Max. and min. temperature (electronics) : -20ºC to +55ºC (-4ºF to +131ºF)
- Flammable atmosphere approval : Safe area: compatible with approved dB transducers allowing installation to zone 0
- CE approval : EMC approval to BS EN 50081-1:1992 for emissions and BS EN50082:1995 for immunity, and to BS EN61010-1:1993 for low voltage directive
- Power supply : 85-264V ac 50/60Hz, 22-28V dc
PERFORMANCE:
- Accuracy : 0.1% of the maximum range
- Resolution : dBMACH3 0.25mm, dB3 0.5mm, dB6 and dB10 1mm, dB15 1.5mm, db25 2.5mm, dB40 5mm
- Range : Depending upon transducer, from 125mm to 40m (0.41 - 130ft)
- ECHO PROCESSING:
- Description : DATEM (Digital Adaptive Tracking of Echo Movement)
INPUTS/OUTPUTS:
- Volt-free contacts : 10 in total. Relays 1-5 form C (SPDT 5A, 220V ac.
- Relays 6-10 form C (SPDT) 3A, 220V ac
- Digital inputs : 7 No or NC with 24V dc internal supply, available max. 20mA
- Analogue output (adjustable) : 2 off Isolated outputs of 4-20mA or 0-20mA into 500Ω (user programmable and adjustable) 0.1% resolution
- Serial output : RS232 via RJ11 port
- Display : 6 digits plus 12 character text, plus bargraph with direction indicators, remote communicator idintifier and program/run/test mode indicators
PROGRAMMING:
- On-board programming : Standard with integral keypad
- PC programming : Via RS232 (RJ11 port
- Programming security : Via password (user selectable and adjustable)