TAPI - Model T500U - CAPS Trace-level NO2 Analyzers with NumaView™ Software
From Nitrogen Compound Instruments
The T500U CAPS NO2 Analyzer represents the next generation of criteria pollutant monitoring technology for the direct measurement of Nitrogen Dioxide (NO2) in air. The instrument utilizes a patented Cavity Attenuated Phase Shift (CAPS) technique to provide an extremely sensitive, fast and accurate NO2 measurement in a cost effective and low maintenance instrument package.
Description:
The T500U provides a direct NO2 measurement, eliminating the need for catalytic conversion or reagents which introduce measurement artifacts inherent in traditional heated metal converter based chemiluminescense instruments. The CAPS measurement approach also reduces maintenance items, and removes the need for hazardous materials and high temperature scrubbers within the instrument. The T500U has an expected maintenance interval of one year under typical ambient monitoring conditions.
All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/0, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.
The model T500U comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
Features:
- True, Direct NO2 measurement
- Extended maintenance interval
- No converter or reagent required
- No known ambient air interferences
- Fast response
- Exceptional measurement sensitivity
- Low power consumption
- Ranges: 0-5 ppb to 0-1 ppm, user selectable
- Adaptive signal filtering optimizes response time
- Temperature & Pressure compensation
- All standard T-Series platform features
- Two-year warranty
Specifications:
- Ranges : 0 - 5 ppb to 0 - 1 ppm NO2
- Measurement Units : ppb, ppm, μg/m3, mg/m3 (selectable)
- Zero Noise : < 20 ppt (RMS)
- Span Noise : < 0.2% of reading (RMS) + 20 ppt
- Lower Detectable Limit : < 40 ppt
- Zero Drift : < 0.1 ppb / 24 hours
- Span Drift : < 0.5% of reading / 24 hours
- Rise/Fall Time : < 30 seconds to 95%
- Linearity : 1% of full scale
- Precision : 0.5% of reading above 5 ppb
- Sample Flow Rate : 900 cm3/min ±10%
- Power Requirements : 80W; 100-250VAC (50-60Hz)
- Analog Output Ranges : 10V, 5V, 1V, 0.1V (selectable)
- Recorder Offset : ±10%
- Included I/O :
- 1 x Ethernet: 10/100Base-T
- 2 x RS232 (300-115,200 baud)
- 2 x USB device ports
- 8 x opto-isolated digital outputs
- 6 x opto-isolated digital inputs
- 4 x analog outputs
- Optional I/O :
- 1 x USB com port
- 1 x RS485
- 8 x analog inputs (0-10V, 12-bit)
- 4 x digital alarm outputs
- Multidrop RS232
- 3 x 4 - 20mA current outputs
- Operating Temperature Range : 5 - 40°C (with US EPA Approval)
- Dimensions (HxWxD) : 7” x 17” x 23.5” (178 x 432 x 597 mm)
- Weight : 33 lbs