Tekran - Model Series 3300Xi - Mercury CEM Electric Generating Unit
The Tekran Series 3300Xi Mercury CEM is in place at over 130 sources in the U.S. For every installation, we have met and exceeded all performance requirements for our customer’s state and federal regulations. Tekran® is the most experienced mercury monitoring resource in the world and continues to lead in mercury compliance monitoring, abatement system control and mobile testing systems.
Products Details
In reliability, system availability and analytical accuracy, the Tekran® Series 3300Xi systems have outperformed all competitors in EPA and private tests in wet and dry stacks. The Series 3300Xi can measure total, elemental and ionic mercury in virtually any combustion source. The system is sensitive enough to measure levels at any coal fired power plant or other industrial emissions source, and is immune to the interferences that plague conventional mercury CEMs.
Air Pollution Control Equipment: Performance Guarantees and Acceptance Testing
Architect engineers, consultants, and end users are seeking validation of mercury abatement technologies including, but not limited to:
- Pre-combustion chemical additives
- Post-combustion treatment
- Mercury oxidizing technologies
- Wet scrubber additives
- Custom mist eliminators
Current specifications requiring performance guarantees may be challenging to comply with:
- Inlet/outlet conditions are ill-defined
- Sorbent trap systems may over estimate gaseous Hg
Tekran is the only company providing all the following:
- Ten years of HgCEMS design, manufacture, and service support
- Multi-point HgCEMS sampling technology for inlet/outlet testing
- NIST Traceability ¡V Tekran 3310 low and high level generators used by NIST
- Low-level measurements certifications of accuracy (EPRI, EERC, CATM, ICCI)
- Service personnel average 10,000 hours of field and laboratory experience
- Parts, training, and support by phone, email and remote access
Key Features
- Patented mercury speciation technology to determine elemental, ionic and total mercury
- Unaffected by SO2, NOX, CO, HCl and all other common combustion by-products
- Interfering acid gases removed without chemical reagents or solid sorbents
- Provides real-time feedback for mercury control technology optimization
- Detection limit of 0.01 ug/m3 as determined by EERC/ICCI independent study
- Low-cost calibration eliminates expensive mercury calibration gas cylinders
- No chemical reagents required
Electronics Platform
Electronics Platform
- Network enabled
- Touch screen interface
- Local data storage and front panel USB port
- Remote access (troubleshooting, control and configuration)
- Improved data and instrument parameter logging
- Additional functionality via optional s/w plugins (std. additions, remote valve control, and much more)
Detector
- New lamp stabilizer and detector electronics
- Easy cuvette removal via convenient fitting interface
- Improved stability and sensitivity
- Digital PMT control and display
Permeation Source
- Lower dead volume permeation chamber
- Digital permeation source set point and display
- Improved accessability
Cartridge / Valve Assembly
- New low dead volume valve assembly
- Constant power heater control
- Faster cartridge cool down with individual high-velocity fans
Physical Layout
- Reduced height from 5U (8.75”) to 4U (7”)
- Improved component accessibility for routine maintenance