Singer Valve - Model 106/206-A-Type 1 - Two-Way Flow Altitude Control Valve
From Level Control Valves
The 106-A-Type 1 and 206-A-Type 1 altitude control valves are based on the 106-PG or 206-PG main valve and are ideal for maintaining a preset maximum water level. The valve functions as a two position control valve, either fully open or fully closed. The Type 1 allows normal forward flow to fill the reservoir to the maximum level and then closes drip-tight at the set-point. It opens to allow reverse flow through the valve when the supply pressure drops a fixed amount below the reservoir head. When a higher supply pressure is restored, the Type 1 valve will then allow normal forward flow to refill the tank to the maximum level.
-
Most popular related searches
Key Features
- No overflows
- Superior repeatability
- Positive shut-off
- Easily serviceable at ground level
Schematic Drawing
- Main Valve - 106-PG or 206-PG - with X107 position indicator
- Isolation Valve
- Strainer - 40 mesh stainless steel screen
- Model 10 Check Valve
- Closing Speed Control
- Model 12 Check Valve
- Model 301-4 Altitude Pilot
- Altitude Gauge
- Fixed Restriction - 1/8 in / 3.2 mm
- Union
- Isolation Valve
- Connection to Reservoir - complete in field
- Model 12 Check Valve
- Isolation Valve
Standard Materials
Standard materials for pilot system components are:
- Ductile Iron
- Stainless Steel
- Brass
- Copper
Specifications:
106 / 206-A-Type 1 Two-Way Flow Altitude Control Valve
- The valve shall be a Singer Valve model 106-A-Type 1 / 206-A-Type 1, size “_____”, ANSI Class 150 (ANSI 300, ANSI flanges drilled to ISO PN 10 / 16 / 25 or 40) pressure rating / flange standard, globe (angle), style valve. The Model 301-4 Altitude Pilot spring range (elevation) shall be “___ to ___” feet / meters, with set-point preset at Singer Valve to “___” feet / meters. Assembly shall be according to Schematic A-0412D.
- The valve allows normal forward flow to fill the reservoir to the maximum level then closes drip-tight at the set-point. It opens to allow reverse flow through the valve to distribute to users when the supply pressure drops a fixed amount below the reservoir head. When a higher supply pressure is restored the Type 1 will then allow normal forward flow to refill the tank to the maximum level.
- Refer to Main Valve section, page 11, 106-PG (or 206-PG) and Main Valve Options section, Model X107 Position Indicator for detailed information pertaining to valve sizes and materials, selection criteria and specifications.
- Refer to Pilot and Accessories, page 249, section, Model 301-4 Altitude Pilot for detailed information pertaining to materials and specifications.
Customer reviews