GDS - Model 301 - Single Line Sample Unit
From Flow Sample System
Continuous monitoring. Flammable, oxygen or toxic gases. Easily installed and maintained. 2 alarm levels & relays. 4~20mA analogue output. Line blockage and pump fail monitor. Delay to alarm option.
-
Most popular related searches
Application
The GDS 301 system is designed to monitor gas levels in situations where the positioning of conventional gas sensors may not be practical. This may be due to equipment security, cable routing, access for detector head installation/maintenance, harsh environment or a cost effective means of monitoring designated hazardous areas, typically - tunnels, marine applications, underground/high level voids, process control, brewing, horticulture, livestock husbandry.
Operation
A gas sample is continuously extracted via a fixed sample line from the target area. The central unit provides gas level readouts with two alarm trip points, providing a range of signal outputs for annunciator or control functions.
A wide range of sensor devices are available to suit customer requirements which include infra red, electrochemical, catalytic and other specialist sensors which offer a 4~20mA signal output.
Technical Data:
- Measurements :
- Combustible Gas L.E.L %Vol, ppm
- Toxic Gas - ppm, %Vol
- Oxygen - % Vol
- Power Supply : 230/115vAC or 24vDC ± 15% The two voltages may be used simultaneously
- Frequency : 50/60Hz
- Consumption : 10 watts
- Alarm Settings : Digital setting (fully adjustable between zero and full scale)
- Alarm delay :
- T1 - 10 seconds, T2 - 30 seconds,
- T1 + T2 - 10 minutes
- Indicators :
- Power - Green L.E.D.
- Alarms - Low/High - Red L.E.D.
- Flow fail - Amber L.E.D.
- Fault - Amber L.E.D.
- System test alarm L.E.D's flashing
- Outputs :
- Low alarm relay - S.P.C.O
- High alarm relay - S.P.C.O
- Fault alarm relay - S.P.C.O
- Flow fail - S.P.C.O
- Relays rated 5A/230vAC
- ND or NE pre set normally de-energised
- Analogue 4-20mA/1-5v
- 24vDC - 100mA max (Auxiliary equipment supply)
- Audible Alarm : Low, High gas and Fault Permanent mute option
- Reset Switch : Auto or Manual - pre set manual
- Test Switch : Used to check alarm indicators, sounder and relay action
- Inhibit : Isolation of alarm relays during service
- Protection : IP65
- Environmental :
- Ambient temperature -5 to 45°C
- Storage temperature +10 to 60°C
- Humidity range 0 - 90 RH
- Cable Entry : Rear, side, top, bottom
- Sample Tube :
- 6mm OD 4mm ID
- Max. length 100m
- Exhaust port : 8mm OD
- Miscellaneous :
- Dimensions 315mmW 265mm H 95mm D
- Weight 3.8kg
- Cable entry - bottom, sides, rear
Customer reviews