Uranium Waste Equipment For Soil And Groundwater Available In Hawaii
-
PremiumManufactured by Metrohm AGbased in SWITZERLAND
Voltammetry, being highly specific, can deal with high salt loads. Organic contamination of a sample, however, can interfere with the VA trace analysis of heavy metals. The 909 UV Digester quickly and effectively breaks down organic molecules by UV photolysis, thereby enabling reliable determinations. ...
-
PremiumManufactured by Lumex Instrumentsbased in CANADA
FLUORAT-02 is a multifunctional fluorescence analyzer intended for analysis of water, soil, foodstuff, etc. This instrument determines a wide range of analytes based on fluorescence, chemiluminescence, phosphorescence and photometry ...
-
PremiumManufactured by HI-Q Environmental Products Company, Inc.based in USA
The PAM-100 and PAM-170 series meters are portable hand-held user-friendly and ergonomically designed instruments intended for measuring surface contamination of alpha, beta and gamma emitting radionuclides (depending on the detectors used). Smart gasless scintillation detectors with an active area of 100 cm^2 or 170 cm^2 are used. A dual phosphor detectors with two channel electronics for alpha ...
-
PremiumManufactured by Lenntech Water Treatmentbased in NETHERLANDS
LENNSORB 101 is a high performance adsorbent based on granular ferric hydroxide. Made in a patented manufacturing process, it was special developed for selective removal of heavy metals and other toxic elements from water. Recognized for its high quality, LENNSORB 101 adsorbent complies with all requirements of DIN ...
-
PremiumManufactured by Excalibur Water Systems Inc.based in CANADA
The Excalibur Filtermax Uranium Filter removes the uranium in your water ...
-
PremiumManufactured by Lenntech Water Treatmentbased in NETHERLANDS
Lewatit TP 207 is a premium grade weakly acidic, macroporous-type ion exchange resin with chelating iminodiacetate groups for the selective removal of heavy metal cations from weakly acidic to weakly basic ...
-
Manufactured by Efficiency Scientific Instrument Co., Ltd (ESI)based in CHINA
The assay lab that gives you completely non-destructive results in second. Jewelers, recyclers, and refiners of precious metals and alloys require elemental analytical capabilities that fit their challenging business conditions. Affordability is always key. Small operators have comparatively little cash for equipment. Larger concerns face constant pressure to keep costs low and profits high. ...
-
Manufactured by Felite Resin Technology Co.,ltdbased in CHINA
FA127 is a high capacity, shock resistant, gelular, Type I, strongly basic anion exchange resin supplied in the chloride or hydroxide form as moist, tough, uniform, spherical beads. FA127 is intended for use in the hydroxide form for all types of deionizing systems as well as in the chloride form for removal of contaminants such as nitrate, arsenate, chromate, uranium, etc. It is similar to FA124 ...
-
Manufactured by Century Geophysical LLCbased in USA
The Multi-Parameter E-Log, Neutron logging tool was developed to replace the 9055 which was historically Century’s most popular tool. The tool duplicates all parameters on the 9055 while adding the 16 inch normal, 64 inch normal, and lateral resistivity. The 9057 natural gamma circuit features a low dead time and the ability to measure very high count rates making it a favorite for uranium ...
-
Manufactured by Cianflone Scientific a KTC Instruments Companybased in USA
PortaSpec® 2501 Series X is capable of performing multi-element sequential analysis in the range of Ti to U and is ideal for measuring coating weights of both chrome and titanium pretreatment. Cianflone’s PortaSpec 2501 Series X is similar to the Model 2501 XBT. It contains a rotating goniometer that allows the user to analyze up to five elements, preset sequentially one at a time. Its ...
-
Manufactured by Applied Rigaku Technologiesbased in USA
NEX CG II is a multi-element, multi-purpose EDXRF spectrometer that performs rapid qualitative and quantitative trace elemental analyses and addresses needs across many industries. This next-generation, high-end spectrometer is ideal for trace heavy metal and halogen analysis, which is in increasing demand for several sectors. These capabilities make NEX CG II especially well-suited for trace ...
-
Manufactured by Suzhou X Chemical Co.,Ltdbased in CHINA
Anion resin for anionic metal complexes.Suzhou X Chemical has a range of products tailored for recovery of precious metals from electroplating solutions, leaching solutions and seawater. Ion exchange resins are commonly used to remove trace levels and to concentrate precious metals such as Uranium, Gold, Molybdenum, Rhenium, Nickel, Copper and other valuable metals. The metals are then recovered ...
-
Distributed by Kidde Canadabased in CANADA
The Kidde 442020 Radon Detector Kit is EPA registered and makes testing for radon easy. Included in the Kidde 442020 Radon Detector Kit are instructions, an information card, a return mailer envelope, and an activated charcoal radon sampler bag. To test for radon place the radon sampler bag in an ideal location for three days, and then just mail the bag in the enclosed envelope to Alpha Energy ...
-
Manufactured by Technical Associatesbased in USA
The Super Morad, multi-detector module into the van or truck and hooks it up. He now has a mobile radiation laboratory. Working from this well-outfitted mobile lab is very effective. If the test is positive the on-board GPS communication system automatically calls in the results to the shift captain and to the main computer. Then the team can make additional on-the-spot measurements to map and ...
-
Manufactured by Northey Technologies Ltdbased in UNITED KINGDOM
The 36 series uses the proven Northey design of hooked rotor. It is available in a range of rotor widths, with either direct drive or V belt arrangements. Machines can be supplied as bare shaft units or skid mounted complete with motors, valves, instrumentation and control. Cooling can be achieved by using a closed circuit radiator system or flow from any suitable water ...
-
Manufactured by WesTech Engineering, LLCbased in USA
The AltaFlo™ ultra high-rate thickener is a rake-less thickener that provides mixing, flocculation and internal dilution followed by clarification and positive sludge collection and removal in a single tank. The principles of flocculation have been further adapted to a new design that will thicken slurries at an even higher rate than a typical high-rate ...
-
Manufactured by AlpHa Measurement Solutionsbased in USA
Uranium100 Sensor Package of 100 Sensors and Accessories. The sensors are designed to be used with the AND1000 Fluorimeter (See separate product specifications). The DNAzyme reaction produces quantitative fluorescence based results. Each disposable color-coded sensor is designed for a specific heavy metal test target. All disposable components for each test are included in the kit. Uranium100 ...
-
based in USA
With over 15 years of chemical amendment addition experience by industry-leading design engineers, ARS uses a wide range of materials/chemicals when designing remediation options involving chemical oxidation. ARS’ Design Engineers will select the chemical and an activator as needed based on site specific factors, including the target contaminants, lithology, and hydrogeology. Equally as ...
-
based in UNITED KINGDOM
EIRIS Global Controversial Weapons Watch has screened around 14,500 companies worldwide to provide investors with a complete assessment of corporate involvement in controversial ...
-
Manufactured by Innov-X Canadabased in CANADA
DELTA Lead Based Paint Handheld XRF Analyzers test for Lead (Pb) in seconds. These reliable, tube-based units are light in weight and ergonomically designed for all-day testing. They start fast and stay fast - no isotope fade. And, they have a low total cost of ownership. Before you begin industrial repair - grinding, cutting or painting - screen for Pb; then, check your work area after clean-up. ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you