TAPI Waste And Recycling Equipment In Africa
-
Manufactured by Teledyne APIbased in USA
The Model 470 is a state-of-the-art Dissolved Ozone Sensor designed for semiconductor Wet Bench tools and many other industrial processes. It provides continuous measurement of dissolved ozone in deionized water or sulfuric baths with concentrations above 150 mg/L. The Model 470 is “clean-ready” for high purity semiconductor processes, and is designed to be simply spliced in-line in ...
-
Manufactured by Teledyne APIbased in USA
The Model T265 is the only commercially available US EPA Federal Reference Method for Ambient Ozone Monitoring according to the latest US EPA regulatory rules for O3. The instrument uses Chemiluminescence with Nitric Oxide (NO) as a reagent, making it safe, stable, and effective for all applications. The NO-CL method for Ozone has several advantages over the conventional UV absorption technology, ...
-
Manufactured by Teledyne APIbased in USA
Teledyne API, a recognized leader in Ozone measurements, is pleased to offer the Model 430 O3 Monitor. The 430 is a compact instrument that uses the proven UV-absorption principle. The small footprint and robust design make it ideal for a variety of applications where portability and accuracy are both ...
-
Manufactured by Teledyne APIbased in USA
The ODS series of High Concentration High Purity Ozone Gas Delivery Systems is designed for use in the most demanding semiconductor applications. This highly reliable ODS is ideal for applications requiring high concentration ozone at a wide range of flow rates. The ODS system is a complete turnkey solution that is custom configured to plug and play with most semiconductor tools. Its ...
-
Manufactured by Teledyne APIbased in USA
The Model T100 uses the proven UV fluorescence principle, coupled with a state of the art user interface to provide easy, accurate, and dependable measurements of low level ...
-
Manufactured by Teledyne APIbased in USA
The Model T102 TRS analyzer uses the proven UV fluorescence principle to measure Total Reduced Sulfur at levels commonly required for ambient air monitoring. The Model T102 uses a high temperature external converter set at 850°C to allow conversion of H2S, methyl mercaptan, dimethyldisulfide, and methyl-disulfide to SO2 at this temperature with efficiency greater than 98%. A switching option ...
-
Manufactured by Teledyne APIbased in USA
The Model T108 Total Sulfur analyzer is designed to measure mixed sulfur impurities, collectively referred to as Total Sulfides, in air or carbon dioxide gas. Since there is no scrubber in the system, the instrument reading is the sum of the oxidized sulfur compounds and ...
-
Manufactured by Teledyne APIbased in USA
Using a gas filter correlation wheel, the Model T360M Mid-Range CO2 Analyzer measures carbon dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. This design produces excellent zero and span stability and high signal-to-noise ratio, allowing excellent performance over a wide concentration range, making this instrument an ...
-
Manufactured by Teledyne APIbased in USA
The T500U CAPS NO2 Analyzer represents the next generation of criteria pollutant monitoring technology for the direct measurement of Nitrogen Dioxide (NO2) in air. The instrument utilizes a patented Cavity Attenuated Phase Shift (CAPS) technique to provide an extremely sensitive, fast and accurate NO2 measurement in a cost effective and low maintenance instrument ...
-
Manufactured by Teledyne APIbased in USA
The Model T200H combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. A high-efficiency stainless steel thermal NO2 converter provides durable and consistent operation under the harshest conditions (other converter options also ...
-
Manufactured by Teledyne APIbased in USA
The Model T200 NO/NO2/NOx analyzer uses the proven chemiluminescence detection principle, coupled with state-of-the-art electronics to allow accurate and dependable low level measurements for use as an ambient analyzer or dilution CEMS ...
-
Manufactured by Teledyne APIbased in USA
The Mini ODS is a compact, integrated ozone delivery system designed to produce ozone concentrations of 21% w/w, 320g/Nm3 for a wide range of wafer processing applications. It is a very compact yet complete ozone delivery system, including: a high purity ozone generator, high concentration ozone monitor, microprocessor based controller, and all the required regulators and pneumatics. The Mini ODS ...
-
Manufactured by Teledyne APIbased in USA
The Model T200P provides measurements of NO and NO2 using our Model T200 NOx analyzer combined with a patented high efficiency photolytic converter. Even low temperature molybdenum converters transform other nitrogen-containing compounds such as HNO3, PAN, etc. to a considerable extent. Simultaneous measurements of NO2 performed with molybdenum and photolytic converters have shown significantly ...
-
Manufactured by Teledyne APIbased in USA
The Model T300U Trace-level CO analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. Using IR absorption with a Gas Filter Correlation Wheel, the T300U is designed to allow ultra-sensitive CO measurements while still meeting the requirements for use as a US EPA compliance ...
-
Manufactured by Teledyne APIbased in USA
The Model T300 measures low ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert ...
-
Manufactured by Teledyne APIbased in USA
The Model T400 UV Absorption analyzer uses a system based on the Beer-Lambert law for measuring low ranges of ozone in ambient air. ...
-
Manufactured by Teledyne APIbased in USA
The OG-5000 series of ozone generators is designed to produce high concentrations of ultra clean ozone gas for use in semiconductor applications including CVD, ALD thin film, oxide growth and wet bench cleaning processes. The OG-5000 series has a compact, water cooled design that can be easily integrated with Teledyne API's ozone system controller, ozone leak detectors, ozone concentration ...
-
Manufactured by Teledyne APIbased in USA
The Model T200UP provides trace level measurements of NO and NO2 using our Model T200U NOx analyzer combined with a patented high efficiency photolytic converter. Even low temperature molybdenum converters transform other nitrogen-containing compounds such as HNO3, PAN, etc. to a considerable extent. Simultaneous measurements of NO2 performed with molybdenum and photolytic converters have shown ...
-
Manufactured by Teledyne APIbased in USA
The Model T200M combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. The option of either a molybdenum converter or a high-efficiency stainless steel thermal NO2 converter allows the T200M to be used in a variety of extractive CEM systems, from gas turbines to ...
-
Manufactured by Teledyne APIbased in USA
The Model 465M is a microprocessor based medium range ozone monitor for measuring process ozone concentrations in water treatment, food processing, and research applications. The design has been specifically optimized for applications requiring the measurement of ozone at near-ambient pressure such as water treatment contactor off-gas measurement. The Model 465M has been designed to give accurate ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you