monitor dissolved oxygen Articles

  • ppb Dissolved oxygen measurement

    Dissolved oxygen (D.O.) measurement is one indicator of water quality because oxygen is a common element contributing to corrosion reactions. This corrosion reaction provides the need for low level D.O. control since dissolved oxygen is responsible for costly replacement of piping and equipment by corrosive attack on metah. what is Dissolved Oxygen? Dissolved axygan (D.O.f is the ...


    By IC Controls Ltd.

  • Dissolved oxygen’s effect on ecosystems

    Dissolved oxygen (DO) is a measure of the amount of oxygen dissolved in water. It can be caused by a process of aeration of water flowing through rapids or falls, a byproduct of photosynthesis and the atmosphere. Monitoring DO levels in water may be more important than you think. From dead fish washing up on the shores of Singapore, to historically low levels of brown shrimp, DO is having an ...


    By Aquaread Limited

  • Dissolved Oxygen – the discussion moves on

    Do Dissolved Oxygen Sensors need Cleaning? The re-emergence of Optical Dissolved Oxygen Sensors around 6-7 years ago generated a lively and interesting discussion which revolved around the relative merits of Optical and Galvanic Dissolved Oxygen sensors. We understand that opinions will differ, so in order to accommodate our customers preferences we are pleased to offer our OxyTechw² ...


    By Partech (Electronics) Ltd.

  • Boiler Dissolved Oxygen Control

    DISSOLVED OXYGEN CHEMISTRY Dissolved Oxygen (DO) is a measure of the amount of oxygen, usually thought of as a gas, that is dissolved in a liquid such as water. Oxygen is essential to life and is also the most common element found taking part in corrosion reactions. DO can be thought of as the fuel needed for the corrosion process to proceed. It is the corrosion reactions that necessitate ...


    By IC Controls Ltd.

  • ppm Dissolved oxygen measurement

    Dissolved oxygen (D.O.) levels are used as a general indicator of water quality. Oxygen is essential to life and vital for countless aquatic forms. D.O. level control is critical in numerous applications ranging from the monitoring of industrial waste water to environmental surveillance. What is Dissolved Oxygen? Dissolved oxygen (D.O.) is the amount of oxygen gas dissolved in a ...


    By IC Controls Ltd.

  • Continuous on-line monitoring of dissolved oxygen in the activated sludge of a sewage treatment plant

    Dissolved oxygen is traditionally measured using a Clark cell, which relies upon a gas-permeable membrane for its opera-tion. Such sensors are subject to fouling with subsequent loss of accuracy, making frequent maintenance and calibration necessary. The objective of this development was to take advantage of specific properties of microelectrode arrays, such as low flow-dependence, insensitivity ...


  • Why it is important to measure Dissolved Oxygen in aeration lanes

    Dissolved Oxygen is a key parameter in the efficient treatment of waste water during the secondary treatment stage; the point at which organic waste is oxidised to form carbon dioxide, water and nitrogen compounds. It is important to act on accurate measurements of Dissolved Oxygen in activated sludge plants for the following reasons: To ...


    By Partech (Electronics) Ltd.

  • Why it is important to measure Dissolved Oxygen in aeration lanes

    Dissolved Oxygen is a key parameter in the efficient treatment of waste water during the secondary treatment stage; the point at which organic waste is oxidised to form carbon dioxide, water and nitrogen compounds. It is important to act on accurate ...


    By Partech (Electronics) Ltd.

  • Product of the Month – Handy Polaris 2 Portable Dissolved Oxygen Meter with Datalogger

    This month the focus is on the Handy Polaris 2 Portable Dissolved Oxygen Meter with Datalogger. Over the summer months we have seen increased interest in the instrument. Warmer temperatures can affect the chemistry, biological processes and dissolved oxygen levels in water, making the Handy Polaris 2 a popular ...


    By Partech (Electronics) Ltd.

  • Northern Rivers Ecosystem Initiative: Nutrients and Dissolved Oxygen – Issues and Impacts

    Anthropogenic inputs of nitrogen (N), phosphorus (P) and oxygen-consuming material to aquatic ecosystems can change nutrient dynamics, deplete oxygen, and change abundance and diversity of aquatic plants and animals. The Northern Rivers Ecosystem Initiative required a research and assessment program to establish the contribution of pulp mill and sewage discharges to eutrophication and depressions ...


    By Springer

  • Trends in Temperature, Secchi Depth, and Dissolved Oxygen Depletion Rates in the Central Basin of Lake Erie, 1983–2002

    We examined temperature trends in a 20-year set of monitoring records collected at mul- tiple deep-water stations in the central basin of Lake Erie. Data collected were statistically corrected (“deseasonalized”) to remove biases resulting from irregular sampling intervals within years. Depth- integrated summer temperature has increased by an average (±SE) of 0.037 ±0.01°C per year. An observed ...


    By EarthSoft, Inc

  • Spectroscopic characterization of dissolved organic matter in coking wastewater during bio-treatment: full-scale plant study

    This paper taking a full-scale coking wastewater (CWW) treatment plant as a case study aimed to characterize removal behaviors of dissolved organic matter (DOM) by UV spectra and fluorescence excitation-emission matrix-parallel factor analysis (PARAFAC), and investigate the correlations between spectroscopic indices and water quality parameters. Efficient removal rates of chemical oxygen ...


    By IWA Publishing

  • Impact of carbon to nitrogen ratio on nitrogen removal at a low oxygen concentration in a sequencing batch biofilm reactor

    A sequencing batch biofilm reactor (SBBR) filled with polyurethane (PU) was operated in low dissolved oxygen (DO) (0.1–0.9 mg/L) at three different carbon to nitrogen ratios (C/N ratios) (C/N = 1.8:1, 5.0:1 and 10.5:1) with focus on reactor performance and microbial community composition of nitrifying and denitrifying bacteria. ...


    By IWA Publishing

  • Condenser performance monitoring, control and optimization

    Abstract During the past sixteen years, understanding of the condensation process within condensers has been advanced through the introduction of new monitoring and control instrumentation. Data gathered from a variety of condenser types employing these instruments have allowed comprehension of the condensation process to be advanced to the point where underperforming regions of tube ...


    By Intek, Inc.

  • Monitoring pH and ORP in a SHARON reactor

    This paper analyses the valuable information provided by the on-line measurements of pH and oxidation reduction potential (ORP) in a continuous single high ammonia removal over nitrite (SHARON) reactor. A laboratory-scale SHARON reactor equipped with pH, ORP, electric conductivity and dissolved oxygen (DO) probes has been operated for more than one year. Nitrogen removal over nitrite has been ...


    By IWA Publishing

  • Reliable silica monitoring supports power station efficiency

    West Burton B CCGT is a Combined Cycle Gas Turbine power station near Nottingham in the UK. It has three open-cycle gas turbines capable of generating enough electricity for approximately 1.5 million UK homes. In common with all combustion based power stations, the CCGT has a requirement to monitor silica levels in the Plant’s water and steam processes. Sean Todd, the Plant’s Control ...

  • Successful Application of HRC in a Fractured Formation in Tennessee (PDF)

    Under Tennessee’s Voluntary Cleanup program, a pilot program was successfully implemented using hydrogen-release compound (HRC, Regenesis, Inc.) to address perchloroethene (PCE) and trichloroethene (TCE) contamination in groundwater. Flow direction was known generally, however the fractured nature of the formation precluded specific knowledge of consistent flow across the site. The HRC injection ...


    By REGENESIS

  • Customer Case - Hampton Roads Sanitation District

    At HRSD, the regional wastewater treatment utility that serves southeast Virginia, process engineers and researchers are working with the development of novel processes for nutrient removal from wastewater. One of the primary focuses is the application of the deammonification process directly in the mainstream. Currently, HRSD is operating a fully integrated pilot process and as part of the ...


    By Unisense Environment A/S

  • Nitro Beer Tastes Better

    If you've ever remarked on the smooth creaminess of a pint of Guinness, you've picked up on the key difference in its carbonation: Nitrogen rather than carbon dioxide. Such "nitro" beers have become a trend in recent years, with major U.S. breweries and small startups alike offering nitro products. Nitrogen keeps bitterness in check and balances out the hops to make drinkable craft brews, but it ...

  • Granularity determination of activated sludge through on-line profiles by means of case-based reasoning

    Aerobic granulation from floccular sludge is difficult to detect in first stages with the naked eye. This work proposes a combination of multi-way principal components and case-based reasoning to predict the granulation state of a sequencing batch reactor, based solely on the on-line registered profiles of common sensors (i.e. pH, dissolved oxygen and oxidation-reduction potential). The ...


    By IWA Publishing

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you