groundwater monitoring pump Articles

  • A method for reducing purge volumes in deep monitoring wells: a purging experiment.

    Regulatory agencies often require three well casing volumes or more be purged prior to collection of groundwater samples for chemical analysis. Costs are high for testing and disposing of potentially hazardous purge water; therefore, efforts must be made to minimize waste-water volume while obtaining representative groundwater samples. Lockheed sponsored a purge experiment on two deep monitor ...


    By Hargis + Associates Inc

  • Identifying the impact of Energy Base Water Project on groundwater using high-frequency monitoring data in the Subei Lake basin, Ordos, Northwestern China

    Groundwater is increasingly exploited for energy production in arid regions, which necessitates a deeper insight into the impact of the enhanced human pressure on the groundwater. This study applied an integrated method (statistical analysis, water table fluctuation method, hydrograph analysis and remote sensing) to identify the impact of Energy Base Water Project on the groundwater in the ...


    By IWA Publishing

  • Plume distortion and apparent attenuation due to concentration averaging in monitoring wells

    This paper, authored by University of Connecticut researchers who performed much of the early work on this topic, describe the various processes that bias groundwater samples collected from conventional monitoring wells. In particular, they discuss the dilution of contaminants that occurs when clean water is simultaneously drawn into monitoring wells pumped to produce groundwater ...


    By Solinst Canada Ltd.

  • Cost Savings with Bioremediation

    Introduction Prior operations at a former plating and hard anodizing facility in Santa Clara, California resulted in tetrachloroethene (PCE), trichloroethene (TCE), and cis-1,2-dichloroethene (DCE) impacts to soil and groundwater. In 1987, a groundwater monitoring program was implemented to monitor the plume. In 1998, CDM performed a natural attenuation evaluation for ...


    By Regenesis

  • Relevance of hydrological parameters in artificial recharge sites selection and assessment in a granitic aquifer

    Due to increasing demand of groundwater and indiscriminant pumping, groundwater levels have been declined beyond economic levels and the natural recharge is not enough. Thus enhancing recharge to the groundwater system through artificial means has been evident. Depending on the situation, a variety of methods have been in practice but assessing their efficacy as well as optimal site selection has ...


    By Inderscience Publishers

  • Technical Bulletin: Multilevel Sampling

    The topic of this CL:AIRE Technical Bulletin is multilevel sampling systems for characterising contaminated groundwater. Contaminated groundwater can present considerable problems for landowners: it can occur at significant depth, sources of the contamination are not often obvious, it can migrate from one property to another, and groundwater flow directions can be altered due to seasonal ...


    By Solinst Canada Ltd.

  • Effective Groundwater Monitoring Using Dedicated Pumping Tubes

    This article describes a groundwater monitoring procedure that does not require decontamination of pumping equipment, eliminates the chance of cross contamination between wells, and uses a surface pump.  Two surface pumps are described, one for water level depths less than 25 feet and one for water level depths greater than 25 feet. Install Dedicated Pumping Tubes ...


    By RotaPump, Inc

  • Rikers Island UST design & environmental services

    Design and Permitting of the upgrade fourteen (14) underground diesel & No. 6 fuel oil storage tanks with a combined tankage of over 540,000 gallons for a Major Oil Storage Facility. Project includes subsurface investigation, installation of soil borings, groundwater monitoring wells, non-destructive ultrasonic and volumetric tightness testing of tanks, tank design rehabilitation including ...


    By GEA Engineering PC

  • Modeling of temporal groundwater level variations based on a Kalman filter adaptation algorithm with exogenous inputs

    Reliable temporal modelling of groundwater level is significant for efficient water resources management in hydrological basins and for the prevention of possible desertification effects. In this work we propose a stochastic method of temporal monitoring and prediction that can incorporate auxiliary information. More specifically, we model the temporal (mean annual and biannual) variation of ...


    By IWA Publishing

  • Pump/Recharge Rate Affects Saltwater Intrusion

    Untitled Document Many areas of the world use groundwater as their main source of fresh water supply. With the worlds population increasing ...


    By Solinst Canada Ltd.

  • In Situ Bioremediation of Chlorinated Solvents: A Case Study

    In situ bioremediation is ongoing at a former manufacturing facility in Portland, Oregon. Shallow groundwater at the site was impacted by chlorinated solvents, primarily trichloroethene and degradation products cis-1,2-dichloroethene and vinyl chloride. In situ chemical oxidation treatment was completed in 2003 via the injection of sodium permanganate in source areas. Subsequent stimulation of in ...


    By EOS Remediation, LLC

  • Use of Eight Well Purging and Sampling Record

    This article describes a groundwater well purging and sampling form that can be downloaded at our website. A click on the articles button will take you to a list of Monitoring Tips and Procedures articles, one of which is the sampling form. The form can be used to record  indicator parameters pH, conductivity, temperature, etc., taken during ...


    By RotaPump, Inc

  • Groundwater levels under climate change in the Gnangara system, Western Australia

    The Gnangara system is the main source of freshwater for Perth, Western Australia. However, aquifers in the region are under severe stress due to a drying climate, intensive pumping and changes in land use. The aim of this study is to apply the mean rainfall cumulative deviation and Mann-Kendall analyses at 77 monitoring bores to investigate the response of the water table to key recharge ...


    By IWA Publishing

  • Groundwater: Low-flow Purging and Sampling

    Significant timesavings, improved sample process integrity, quality assurance and minimal quantities of potentially contaminated purge water to manage - are attractive as the focus on groundwater quality sharpens and economics demand best cost-benefit based methods Water has become a vitally important resource.  Maintaining its quality and quantity and avoiding pollution are set to be ...

  • Development of a risk-based approach for better protection of drinking water catchments in Flanders (Belgium)

    Around 70% of the drinking water produced by De Watergroep (a Belgian public water company) is extracted from 83 groundwater pumping sites. To control the risks that endanger the drinking water supply and for the groundwater extracted to be as pure as possible, a risk-based approach for the protection of the catchment areas is developed, as part of the water safety plans. The approach ...


    By IWA Publishing

  • Study of groundwater using visual MODFLOW in the Manas River Basin, China

    For effective groundwater management of a basin, it is essential that a careful water balance study be carried out. A three-dimensional transient-state finite difference groundwater flow model is used to quantify the groundwater fluxes and analyze the dynamic changes of groundwater level. After monitoring groundwater levels for 43 typical observation wells through a simulation study of the ...


    By IWA Publishing

  • In Situ Bioremediation of Chlorinated Solvents

    ABSTRACT: In situ bioremediation is ongoing at a former manufacturing facility in Portland, Oregon.  Shallow groundwater at the site was impacted by chlorinated solvents, primarily trichloroethene and degradation products cis-1,2-dichloroethene and vinyl chloride.  In situ chemical oxidation treatment was completed in 2003 via the injection of sodium permanganate in source ...


    By EOS Remediation, LLC

  • Leaks and spills - LNAP and DNAPL detection and clean up

    Any tank can leak. Most leaks can be cleaned up and responsible operators need equipment that does what’s needed. With an ATEX Zone 0 certified interface meter site operators can successfully achieve LNAP and DNAPL detection when monitoring petrochemical sites, tank farms, petrol station forecourts, landfills or remediation sites. If site technicians detect ...

  • National Grid, Croydon case study

    Morgan Est Contractors for National Grid Supply and installation of telemetred groundwater monitoring network, May 2006 - ongoing Hydro-Logic recently completed the supply and installation of borehole instrumentation and a telemetry monitoring system to monitor groundwater conditions in 28 observation wells located at 19 sites in the vicinity of Croydon. The project was required to ...


    By Hydro-Logic Services

  • Multilevel Systems

    Untitled Document Introduction A multilevel system is a groundwater monitoring device which allows ...


    By Solinst Canada Ltd.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you