  • The first monitoring well in Engbertsdijksvenen is a reality

    On Wednesday 20 December 2017, the first monitoring well of the groundwater monitoring network Engbertsdijksvenen was realised on the parcel of landowner Wilharms in Vriezenveen. This monitoring well serves to monitor the effects of the measures required for the Nature Objectives of the Engbertsdijksveen. One of these goals is the recovery of living high moor. In addition to this monitoring well, ...


    By Eijkelkamp Soil & Water

  • A method for reducing purge volumes in deep monitoring wells: a purging experiment.

    Regulatory agencies often require three well casing volumes or more be purged prior to collection of groundwater samples for chemical analysis. Costs are high for testing and disposing of potentially hazardous purge water; therefore, efforts must be made to minimize waste-water volume while obtaining representative groundwater samples. Lockheed sponsored a purge experiment on two deep monitor ...


    By Hargis + Associates Inc

  • Diver-NETZ Reduced operational costs by 97% - Case Study

    Near-real-time monitoring increased efficiency, reduced costs, and delivered critical insight into groundwater resources Challenge Reduce municipal groundwater monitoring costs, improve data quality, and achieve greater insight into groundwater resources. Solution Upgrade existing monitoring network with Diver-NETZ* wireless groundwater monitoring ...

  • Tidal influences on unconfined water levels in wells.

    Tidal effects have the potential to measurably affect water level measurements and the estimation of groundwater flow direction and gradient. This has significant implications for the prediction and monitoring of contaminant plumes in coastal areas. Studies were conducted at two near-coastal sites in San Diego County, California, to evaluate the impact of tidal variability on the interpretation ...


    By Hargis + Associates Inc

  • Use of Eight Well Purging and Sampling Record

    This article describes a groundwater well purging and sampling form that can be downloaded at our website. A click on the articles button will take you to a list of Monitoring Tips and Procedures articles, one of which is the sampling form. The form can be used to record  indicator parameters pH, conductivity, temperature, etc., taken during ...


    By RotaPump, Inc

  • Plume distortion and apparent attenuation due to concentration averaging in monitoring wells

    This paper, authored by University of Connecticut researchers who performed much of the early work on this topic, describe the various processes that bias groundwater samples collected from conventional monitoring wells. In particular, they discuss the dilution of contaminants that occurs when clean water is simultaneously drawn into monitoring wells pumped to produce groundwater ...


    By Solinst Canada Ltd.

  • Optimal design of groundwater-level monitoring networks

    Groundwater monitoring plays a significant role in groundwater management. This study presents an optimization method for designing groundwater-level monitoring networks. The proposed design method was used in the Eshtehard aquifer, in central Iran. Three scenarios were considered to optimize the locations of the observation wells: (1) designing new monitoring networks, (2) redesigning ...


    By IWA Publishing

  • Optimal groundwater contamination monitoring using pumping wells

    This study presents a new method for selecting monitoring wells for optimal evaluation of groundwater quality. The basic approach of this work is motivated by difficulties in interpolating groundwater quality from information collected for only few sampled wells. The well selection relies on other existing data relevant to contaminant distribution in the sampling domain, e.g. predictions of ...


    By IWA Publishing

  • Radon distribution in groundwater of Taiwan

    Radon levels were surveyed in 517 monitoring wells constructed in five major groundwater areas of Taiwan. The radon concentration in groundwater samples varied in a wide range from below the detection limit of 18 pCi/L up to 1,100 pCi/L. A worldwide comparison of reported groundwater radon levels was conducted. Overall radon levels in Taiwan groundwater are relatively low compared to other ...


    By Springer

  • Groundwater Plume, Source and Risk Identification Using Passive Soil Gas

    Abstract The results from sixty passive soil gas (PSG) samplers placed at a grain silo and mixed-use industrial facility with a known chlorinated solvent release aided with the rapid investigation time-schedule. The samplers were used to determine potential sources, plume extent and vapor risks in areas beyond the previous discrete soil sampling and permanent groundwater monitoring well ...

  • Using solver to determine vertical groundwater velocities by temperature variations, Purdue University, Indiana, USA

    Vertical groundwater velocities can be estimated based on directions of groundwater thermal gradients. Temperature-depth profiles were obtained from 12 monitoring wells at 3 different times of the year (Fall, Winter, and Spring) in West Lafayette, Indiana (USA) mainly on the Purdue University campus. Microsoft Excel Solver was used to match plots of groundwater temperature distribution in the ...


    By Springer

  • Use of geostatistics to evaluate the monitoring well network of a TCE plume

    This paper summarises the use of geostatistics to evaluate an existing network of wells in a groundwater monitoring program. The primary objective was to evaluate whether selective well removal would result in a comparable characterisation of a trichloroethylene (TCE) plume. For adequate characterisation, it is important to retain enough wells to evaluate areas with higher concentrations and to ...


    By Inderscience Publishers

  • Remediation of BTEX in Groundwater with LNAPL Using Oxygen Releasing Materials (ORM).

    Abstract: A field scale study was conducted at a former gasoline service station to evaluate the remediation of groundwater contaminated with dissolved benzene, toluene, ethylbenzene, and xylenes (BTEX) using oxygen-releasing materials (ORM). The injection of oxygen through ORM slurry was the remedial alternative chosen to enhance the in-situ microbial degradation of the BTEX in groundwater. ...


    By Regenesis

  • Extraction well design for DNAPL recovery.

    The potential for downward migration of dense nonaqueous phase liquid (DNAPL) into deeper portions of a saturated hydrogeologic unit has important implications for successful groundwater remediation. Little information has been published regarding the design of extraction wells that allow DNAPL recovery without simultaneously creating a conduit for cross contamination by vertical migration ...


    By Hargis + Associates Inc

  • Natural attenuation: better than groundwater extraction?

    Monitored natural attenuation (MNA) was evaluated and implemented in May 2000 as a replacement for groundwater extraction and treatment as the long-term remedy for a chlorinated ethene plume at a Superfund site in Washington (Lehmicke et al. 2000). MNA was approved because the plume met the first two lines of evidence in EPA’s protocol on natural attenuation for chlorinated solvents (U.S. EPA ...


    By Hargis + Associates Inc

  • Why You Should Monitor Groundwater?

    What is groundwater? Groundwater is water that is stored below the earth’s surface. When rain or other sources of water come into contact with the ground, the majority of it travels below the surface. Though much of this moisture is then absorbed by plants or returned to the atmosphere (through infiltration), some water will travel deeper beneath the surface – where it ...


    By Aquaread Limited

  • Rikers Island UST design & environmental services

    Design and Permitting of the upgrade fourteen (14) underground diesel & No. 6 fuel oil storage tanks with a combined tankage of over 540,000 gallons for a Major Oil Storage Facility. Project includes subsurface investigation, installation of soil borings, groundwater monitoring wells, non-destructive ultrasonic and volumetric tightness testing of tanks, tank design rehabilitation including ...


    By GEA Engineering PC

  • Combining thermal treatment with MNA at a brownfield DNAPL site

    Abstract A heavily contaminated Brownfields site in New York was remediated and redeveloped using a combination of In-Situ Thermal Desorption and Monitored Natural Attenuation. Four source areas were addressed by the thermal technology, and groundwater beneath the site is undergoing natural attenuation. Approximately 86,000 lbs of volatile organics were extracted and treated on-site. The ...

  • Prevention measures against radiation exposure to radon in well waters: analysis of the present situation in Finland

    Naturally occurring radioactive elements are found in all groundwaters, especially in bedrock waters. Exposure to these radioactive elements increases the risk of cancer. The most significant of these elements is radon which, as a gas, is mobile and dissolves in groundwater. In Finland, water supply plants are obliged to carry out statutory monitoring of the water quality, including radon. ...


    By IWA Publishing

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you