Industrial Cooling Articles

  • Green IT

    A holistic approach for identifying sustainable performance Green IT is more than taking single factors into account or realising technical improves such as energy efficiency or lead free components. Green IT has to be considered holistically in order to ensure added value for companies. Often responsibles think only about influencing the use phase, about reduction of heat ...


    By thinkstep

  • Thermoelectric Power Industry Focuses on Water Efficiency

    Power generation currently accounts for large percentage of United States water withdrawals ...


    By Fluence Corporation

  • Beyond Laboratory Research on White Rust and Passivation

    EVAPCO initiated an in-depth study to investigate the formation and control of white rust. This study, which began over three years ago, led to the development of industry-leading research equipment specifically designed to evaluate white rust formation on evaporative heat transfer surfaces. A small-scale closed circuit cooler was designed and built to replicate the dynamic conditions ...


    By Evapco Inc.

  • Energy-efficient Cooling System for Musikkens Hus (House of Music)

    DESMI has delivered and installed highly efficient pumps, pipes and wells for intake of water from the fiord for the cooling system of Musikkens Hus. Musikkens Hus is known as the musical gathering point of Northern Denmark and covers more than 20,000 m2 distributed on nine storeys and among other facilities it hosts four concert halls, five stages, a restaurant, and educational ...


    By DESMI A/S

  • Total heat versus sensible heat evaporator selection methods & application

    Scope The purpose of this paper is to provide specifying engineers, purchasers and users of evaporators in industrial refrigeration applications with an explanation of “total heat” versus “sensible heat” selection methods and how the method used can impact coil capacity, fan horsepower, physical size and first cost of the equipment. This paper provides ...


    By Evapco Inc.

  • ANSI/AHRI standard 420-2008 for fan and coil evaporators - benefits and costs

    Abstract Fan and coil evaporators as used in the industrial refrigeration industry can be certified for performance per ANSI/AHRI Standard 420-2008, Performance Rating of Forced-Circulation Free-Delivery Unit Coolers for Refrigeration. This paper will explain how the standard works and illustrate the costs related to evaporators that may not meet the performance criteria of the standard. ...


    By Evapco Inc.

  • Preventing critical failures in evaporative cooling equipment

    Systematic and thorough attention to the fan and motor assemblies is essential to avoid the unexpected interruption of service. Most catastrophic system failtures are easily avoidable because they are linked to a negligent lack of maintenance. Evaporative cooling equipment, like an mechanical unit of machinery, requires preventative maintenance to maximize its utility. ...


    By Evapco Inc.

  • Evaporative cooling cuts energy costs

    Commercial contractors utilize alternative technology in today’s buildings It is estimated that HVAC systems account for approximately 40 percent of the energy used in commercial buildings, which is why many building owners and managers are looking for ways to cut these costs. One way to do that may be to utilize evaporative cooling systems, which can be relatively inexpensive to ...


    By Evapco Inc.

  • The Internet of Water Is Saving Lives While Battling Pollution

    The Problem A condition known as Legionnaires' disease has made headlines after it killed a dozen people in Flint, Michigan in 2014 and 2015 and sickened hundreds in  ...

  • Using IoT to Stop Saboteurs, Save Water and Make Money

    Griswold Water Systems explains how they modernized their business in an old-school industry and realized unexpected benefits along the way. The Internet of Things often raises security concerns for businesses, but for Griswold Water Systems (GWS), connectivity offered a security solution -- namely, a way to make sure the competition wasn't sabotaging its ...


    By Griswold Water Systems (GWS)

  • IOT TRENDS AND ANALYSIS The Internet of Water Is Saving Lives While Battling Pollution

    he Problem A condition known as Legionnaires' disease has made headlines after it killed a dozen people in Flint, Michigan in 2014 and 2015 and sickened hundreds in  ...

  • Finally - a fan for the 21st century - Case Study

    Travis Luther, owner of Forcefield, designs and builds Advanced Greenhouse Climate Solutions in southern Oregon, USA. He install MagFans in the greenhouses and he is impressed with the powerful, efficient and quiet fan. Production challenges Being in a hot dry climate, we rely on evaporative cooling to keep the temperature from climbing to detrimental levels in the summer. This ...


    By DACS A/S

  • Cooling Systems: Increased Costs from Mineral Scaling and Biological Fouling - Case Study

    Mineral scaling and biological fouling are two of the most common problems associated with watercooled systems, and the costs from these issues can be enormous. By understanding how these issues affect cooling water systems, and their associated cost drivers, facility managers can make informed decisions on proper scale and biological fouling control. Scale Definition ...


    By Innovas Technologies LLC

  • Cooling Towers - AZUD filtration solutions for the Healthcare Center in the Zayed Sports City, Abu Dhabi.

    AZUD supplies the better solution for the treatment of the water used in the cooling systems of one of the most important hospital of the Persian Gulf. Background The Healthpoint of Zayed Sports City is one of most important Healthcare Centers of Abu Dhabi. It has international agreements as the one signed with the Manchester City Football Club. This center offers a premium ...


    By Sistema Azud, S.A.

  • A Refinery saves 25% on biocide dosage by using HydroBio Advance

    Real time determination and monitoring of biofilm in cooling systems 1. KEYWORDS HydroBio® Advance, Cooling system, Biofilm, Biocide consumption 2. BACKGROUND This case study shows how the application of the HydroBio® Advance is used to evaluate the real biocide demand of a cooling system in the petrochemical industry. ...


    By Kurita

  • High speed plastic packaging molds

    Now in the plastic packaging industry, we are not just satisfied with high quality plastic packaging, but also we are seeking high speed. It’s important to plastic packaging industry with high efficiency production capability. It not only can improve their production cycle time, but also save much production cost for profit. Especially, now the competition is very serious. So in order to ...


    By Focare Mould Co.,Ltd.

  • Insufficiently Filled solution - Plastic Injection Molding Defects Solution

    Plastic Molding Defects Solution For Insufficiently Filled: * Use plastics with low viscosity and sound fluidity or adjust prescription of plastics and reduce viscosity of melt. *Improve barrel temperature, increase injection pressure,raise melt temperature to reduce viscosity, and improve plastication quality. *Improve mold temperature and ...


    By Focare Mould Co.,Ltd.

  • Crate mold injection molding machine, crate mould machine

    There are types of crate moulds, such as fish crate mould, bread crate mould, bottle crate mould and ...


    By Focare Mould Co.,Ltd.

  • Study on hydrodynamics and heat transfer of solitary wave on film flow with CFD method

    In this paper, a capacitance probe and high speed camera are adopted to study the solitary wave of falling film on large flat plate experimentally. Two types of solitary wave are studied with a Computational Fluid Dynamic (CFD) method based on the measuring data. The water–air shear stress on the interface of the solitary wave is modelled in the numerical calculation. The results indicate that ...


    By Inderscience Publishers

  • Energy and exergy analyses of a solar–driven absorption cooling system

    In this paper, energy and exergy analyses of an absorption cooling system using H2O/LiBr and solar energy as heat source are conducted. A simple schematic of a chiller and an improved one, are compared using Thermoptim and EES software. An increase in the coefficient of performance (COP) from 0.69 to 0.8 was noticed. Numerical simulations are performed for six values of the ...


    By Inderscience Publishers

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you