Air & Climate Product Alerts
  August 29, 2011

›› Featured products & services that match your interests
GasFinderMC Multi Channel Monitor
By Boreal Laser
Boreal Laser"s GasFinder MC (US Patent No. 5,748,325) measures gas concentrations sequentially in up to eight channels or paths. GasFinder and GasFinder MC employ the same patented (US Patent 5,637,872) TDL(Tunable Diode Laser) technology. GasFinderMC uses a Central Control Unit (CCU) housed in a standard 19" rack cabinet, 6" (15cm) high, containing the laser diode source, drive electronics, detector signal processing and microcomputer subsystems. 
Request More Information   ›› Download Brochure

BMAir - TACS - Control System
By Trans Elektro B.V.
The OCS is a control panel for BMAir Units. Parameters such as user hours can be set and the gas sensors" limit values are freely adjustable. For those who wish to monitor and register the mechanic"s risks more closely there is the option of recording the values of the measured overpressure and gas sensors by data logging. You can then analyse in retrospect how that work progressed. 
Request More Information

Air Permitting & Compliance Evaluation
By Shell Engineering & Associates, INC.
Title V and State Operating Permits Prevention of Significant Deterioration (PSD) Deminimis and Minor Construction Permits

EcoTherm007® - (For the requirements of the European VOC guideline)
By Chemisch Thermische Prozesstechnik GmbH / CTP Air Pollution Control
Especially developed for the requirements of the European VOC guideline. Impressive in concept and with an excellent VOC destruction capability, the Eco-Therm007® convinces with its minimum energy input and an attractive overall cost. Additional advantages include fast start-up, elegant design and ease of transport. 
Request More Information

Standard Odour Abatement System
By Applied Plasma Physics AS
Odour & Particulate Abatement System (OAS 50-600) is based on the use of non-thermal plasma technology treating the entire emission in an intensive plasma field abating odours of industrial emissions efficiently. 
Request More Information   ›› Download Brochure   ›› View Video

Ambient Air Passive Sampler
By Ogawa & Company, USA, Inc.
Ambient Air Passive Sampler for NO-NO2, NOx, SO2, O3, NH3. The Ogawa Sampler is ideal for low-cost air monitoring programs, personal, outdoors and indoors. The only known method of passive simultaneous monitoring of NO & NO2. The Ogawa Sampler is reusable countless times. Only the pre-coated filter pad is expendable. The same sampler is used for all above shown gases. 
Request More Information   ›› Download Brochure

Gas Turbines
By Johnson Matthey Emission Control Technologies
Johnson Matthey provides complete NOx and CO emission control systems for simple cycle gas turbines, from the gas turbine outlet through the stack. Our systems offer high availability and efficiency, while meeting all of today"s stringent emission control standards. We also work with major leading HRSG manufacturers to provide complete solutions for combined cycle applications. 
Request More Information

Dust Filters
By Kopar Oy
Long operational life, low maintenance need, efficient cleanability and high filtration ratio are typical characteristics of our filtration equipment.  We have filters available for individual silos as well as centralized dust removal systems. 
Request More Information

CO2 / Dissolved Carbon Dioxide
By Mettler - Toledo Int. Inc
Besides pH and dissolved oxygen measurements, reliable monitoring and control of the CO2 partial pressure is important for successful fermentation. The oxidation of carbohydrates to CO2 water results from aerobic respiration. METTLER TOLEDO"s new CO2 measuring system is specially designed for in-situ measurement into a bioreactor and therefore "registrates" exactly the same partial pressure as the cell. 
Request More Information

BREEZE - ROADS - Air Quality Dispersion Model
By BREEZE Software and Data / Trinity Consultants
BREEZE ROADS is an air dispersion modeling suite that predicts air quality impacts of carbon monoxide (CO), nitrogen dioxide (NO2), particulate matter (PM), and other inert pollutant concentrations from moving and idling motor vehicles at or alongside roadways and roadway intersections. ROADS can be used in conjunction with the MOBILE5 or EMFAC emission models or other emission data to demonstrate compliance with National Ambient Air Quality Standards (NAAQS), Federal ...
Request More Information   ›› Download Brochure

Carbon Capture And Storage
By Enviro Technology Services plc
Several places in the process needs to be monitored and to transport the sample is difficult. A large dynamic range is needed as the NH3 concentration can vary between 15% volume and a few mg/m3. To use an extractive system in this environment will demand a lot of maintanence. 
Request More Information   ›› Download Brochure

Advertise in this Product Alert
For information on advertising in this product alert, contact us or call USA 1-888-244-5029 / Europe +34 91 395 2969.

© 2011 Environmental Expert S.L.

Content


Unsubscribe | Contact Us or Send Feedback | About Us | RSS

You are receiving this message because you opted-in to receive one or more of Environmental Expert`s 8 Weekly Product Alerts.

If someone has forwarded you this message and you`d like to get a free subscription, register here.

Please do not reply to this email as we are unable to respond from this address. To contact us, click here