Catalytic Air Pollution Control Equipment For Air And Climate
-
PremiumManufactured by Anguil Environmental Systems, Inc.based in USA
Anguil’s thermal and catalytic oxidizer technologies are capable of destroying halogenated organic acids and mixed organic vapor contaminants that are discharged from a variety of industrial process streams. We have also developed several destruction devices specifically for soil and groundwater remediation sites contaminated with chlorinated compounds such as carbon tetrachloride, ...
-
PremiumManufactured by ENVEAbased in FRANCE
Rack 3U monitor using the TDL extractive technology to measure online the NH3 pre and/or post catalyst: SCR (Selective Catalytic Reduction) or SNCR (Selective Non-Catalytic Reduction) ENVEA is offering Laser Gas Detection (LGD) modules with exceptional advantages and value for the customer. Tunable Diode Laser Spectrometry (TDLS), enhanced by proprietary technology, is used for the measurement of ...
-
PremiumManufactured by J.U.M. Engineering GmbHbased in GERMANY
The Model VE 222 is an efficient, all heated and low pressure drop 2-stream sample sequencer, filter and interface for removing solids from two gaseous sample streams. The Model VE 222 utilizes two independent permanently installed all stainless steel mesh sample filters and two independent all stainless steel sample valves in a thermostatic controlled oven to prevent the loss of high molecular ...
-
PremiumManufactured by Anguil Environmental Systems, Inc.based in USA
The Anguil Self-Cleaning Ceramic Filter (SCCF) collects, volatilizes and destroys particulate and condensable organics emitted from industrial process streams. It can be used independently as a filter media on hot and cold process streams or coupled with an oxidation module for total odor, Volatile Organic Compound (VOC) and Hazardous Air Pollutant (HAP) ...
-
PremiumManufactured by ECO Physics AGbased in SWITZERLAND
The nCLD 844 CMhr analyzer is the next generation in high precision nitrogen oxide measurement. Unique in speed and reliability, the nCLD 844 CMhr is modular designed and capable of simultaneously measuring NO, NO2, NOx, NH3 and NOx-amines from hot and humid gas sources without additional cooler. It features a dual inlet option for assessing two different sources at once. The new and intuitive ...
-
PremiumManufactured by OPSIS ABbased in SWEDEN
Waste incinerators, cement plants and power plants need good and reliable measurements of total gaseous mercury. The measurement of total gaseous mercury (TGM) is a challenge due to chemical reactions and contamination. The installed systems will often require a lot of maintanence still not giving reliable ...
-
PremiumManufactured by Synspec BVbased in NETHERLANDS
Monitoring of Sulfur Compounds in the Ambient Air. Synspec GC 955 810 gas chromatograph is specifically designed and built for the measurement of sulfur compounds in the ambient air. The two prominent groups of sulfur compounds that can be detected with this GC are mercaptans and sulfides but additional components such as benzene can be added also. The instrument is equipped with a built-in ...
-
PremiumManufactured by J.U.M. Engineering GmbHbased in GERMANY
The J.U.M 3-900 Portable Heated Methane Only and Total Hydrocarbon Analyzer is a heavy duty FID analyzer to continuously measure methane only or the total hydrocarbons to determine the non methane hydrocarbon concentration within a gaseous sample . This can be ambient air, exhaust gases from a combustion process e.g. stack emissions, from any type of an industrial vent, from an internal ...
-
PremiumManufactured by Anguil Environmental Systems, Inc.based in USA
When catalyst is added to the media chambers of an RTO it is then referred to as an RCO. The abatement device still relies on high energy recovery to minimize auxiliary energy usage. However, the VOC compounds will oxidize at lower temperatures with the use of catalyst, further lowering the need for auxiliary energy. This is a great option for catalyst friendly compounds. Multiple catalyst and ...
-
PremiumManufactured by ECO Physics AGbased in SWITZERLAND
The photolytic converter PLC 860 is capable of selectively converting NO2 concentrations of a few ppt. The PLC 860 is the right choice for NO2 measurements in areas with excellent air ...
-
PremiumManufactured by J.U.M. Engineering GmbHbased in GERMANY
The J.U.M OVF-3000 Portable Heated Total Hydrocarbon Analyzer is a light weight, over the shoulder portable heated FID analyzer to continuously measure the total concentration of hydrocarbons within a gaseous sample. This can be ambient air, exhaust gases from a combustion process e.g. stack emissions, from any type of an industrial vent, from an internal combustion engine, or from any other ...
-
PremiumManufactured by Jacobi Groupbased in SWEDEN
Activated carbons designed for air and gas treatment, covering a diverse set of applications including VOC abatement in air, odour control, solvent recovery, process gas purification, residential and commercial air treatment devices, cigarette filters, and cabin air filters and evaporative loss devices in automobiles. ...
-
PremiumManufactured by Advanced Energy Industries, Inc.based in USA
As a connection-ready thyristor switch with secure operational behavior and load monitoring, the Thyro-S (SCR) power controller switches electric loads, for example, current, voltage, or power. It can be connected to bus systems, used instand-alone operation, or used in combination with all established 2-point process controllers, PLCs, or computer systems. With simple mounting, quick ...
-
PremiumManufactured by Shanghai Metash Instruments Co.,Ltd.based in CHINA
Features: Imported NDIR detector, guaranteeing higher sensitivity and stability. 680? catalytic oxidation technology with Platinum catalyst, especially for seawater test. Optional 20-position autosampler saves 80% time and energy. Modular design, simplifying device operation and maintenance. Multi-functional PC software. High-performance processor,ensuring stable and reliable system running. PID ...
-
PremiumManufactured by Anguil Environmental Systems, Inc.based in USA
Widely considered to be the most energy-efficient oxidizer, Anguil's Regenerative Thermal Oxidizer (RTO) uses ceramic media to recover upwards of 97% of the available energy. What makes our RTO so popular is its ability to repurpose the thermal energy generated during operation to reduce operating costs and energy consumption of the system itself. The regenerative component makes it capable of ...
-
PremiumManufactured by J.U.M. Engineering GmbHbased in GERMANY
The Model 108 dilutes an introduced sample gas in a 1:10 (standard), or a 1:100 (optional) dilution rate to allow the linear measurement of hydrocarbon concentrations above several thousand ppm up to 10% and above. The sample injection method is used in this 190 deg.C heated sample diluter for fast response and improved zero and span stability of a hydrocarbon measurements. The Model 108 is also ...
-
PremiumManufactured by Umwelttechnik MCZ GmbHbased in GERMANY
The catalytic gas purifier also removes hydrocarbons and CO from the treated zero gas. This gas free of HC and CO is suitable as process and carrier gas for gas chromatographs and to produce calibration gas for CO/HC ...
-
PremiumManufactured by Anguil Environmental Systems, Inc.based in USA
Anguil provides a broad line of technologically advanced, yet user-friendly air pollution control products for the abatement of industrial emissions like Volatile Organic Compounds (VOCs), Hazardous Air Pollutants (HAPs), Nitrogen Oxides (NOX) and process odors. Each thermal and catalytic oxidizer product represents a value-engineered system with emphasis on cost minimization for vapor combustion ...
-
PremiumManufactured by HI-Q Environmental Products Company, Inc.based in USA
The “Tri-Car” (Tritium – Carbon) family of 3H and 14C airborne samplers can be configured to sample either quantities of 3H in the form of water or 14C in the form of carbon dioxide. A configuration is available as a differential sampler which converts other forms of 3H and 14C into water and carbon dioxide to obtain a separate sample of HT, elemental hydrogen, 14CO, carbon ...
-
PremiumManufactured by Enviro Solutions Technology Co.,Ltdbased in CHINA
Ammonia is a gas that easily dissolves into water, there are several common detection methods,but ammonia is toxic and corrosive, the current measurement mainly uses the TDLAS direct measurement method. TDLAS is essentially a spectral absorption analysis technology, which uses the selective absorption characteristics of gas molecules for specific wavelength lasers, and analyzes the changes in the ...
Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you