Ambest Electronics (Ningbo) Co Ltd
54 products found

Ambest Electronics (Ningbo) Co Ltd products

Control and Indicating Equipment

Ningo - Addressable Control Panel

The 6002 analogue addressable control and indicating equipment forms the central part of a fire detection and alarm system. The 6002 is compatible with Numens addressable devices and supports both Numens SP and TP loop protocols. Either 125 or 250 devices per loop are supported. Non-addressable devices can also be connected to the 6002, when used with addressable input modules.

Ningo - 6-Loop Expansion Pane

The 6002 loop expansion panel provides six additional analogue addressable loops to expand the device capacity of the 6002 control and indicating equipment. Non-addressable devices can also be connected to the 6002 6-loop expansion panel, when used with addressable input modules. The 6002 6-loop expansion panel provides fire detection and alarm system designers with the increased device capacity required for medium and larger life safety and property protection applications.

Wireless Fire Alarm System

Ningo - Wireless Node

660 manual call points with wireless node connects to addressable fire detection control and indicating equipment. Up to 62 devices can be connected to each addressable loop. 660-002 include a wireless node used to connect to wireless devices to control and indicating equipment.

Ningo - Wireless Node

660 wireless manual call points use a wireless transmission path to connect to Numens addressable fire detection control and indicating equipment via a wireless node. Up to 32 devices can be connected to each addressable node. A pressure-activated displacement element provides a safe and convenient way for building occupants to manually initiate a fire alarm condition. All models have an integral alarm indicator that illuminates when the manual call point has been activated. The indicator can also be configured to flash when polled by the fire detection control and indicating equipment. An internal battery provides 10 years of normal operation.

Ningo - Wireless Smoke Detector

601 smoke detectors use a wireless transmission path to connect to a node located on the addressable loop. Up to 32 detectors may be connected to the node. 601 smoke/heat detectors are compatible with Numens 6002 2‑wire addressable fire detection control and indicating equipment. The detector includes an internal sounder to provide a local alarm signal. If the detector is removed from its base, a fault signal will be released to the CIE. If the wireless transmission path is interru pted, the detector will operate as a stand-alone smoke/heat alarm. An internal battery provides 5 years of normal operation.

Detectors

Numens - Addressable Smoke Detector

SNA-360 analogue addressable photoelectric smoke detectors are microprocessor controlled state-of-the-art detectors suitable for connection to Numens 2-wire addressable fire detection control and indicating equipment. Up to 125 detectors can be connected to each alarm zone loop. Advanced electronics in conjunction with a photoelectric smoke sensing chamber provides early detection of fire and high immunity against unwanted alarms. The SNA-360 analogue addressable detector range provides fire detection and alarm system designers with a premium smoke detector for life safety and property protection applications.


Detector Bases

Ningo - Addressable Detector Base

CN302A detector bases are used with 2-wire fire detection and alarm system detectors and devices that do not include additional features, such as remote indicator or alarm relay outputs. High profile models are available for mounting on solid surfaces, with both rear or side-entry cabling. The range of bases provides fire detection and alarm system designers with Standards-compliant, flexible solutions, including models suitable for mounting on solid ceilings with conduit entry points

Ningo - Addressable Detector Base

CN304A detector bases are used with 2-wire and 4-wire fire detection and alarm system detectors that include additional features, such as remote indicator or alarm relay outputs. High profile models are available for mounting on solid surfaces, with both rear or side-entry cabling.  The range of bases provides fire detection and alarm system designers with Standards-compliant, flexible solutions, including models suitable for mounting on solid ceilings with conduit entry points.

Manual Call Points

Numens - Addressable Manual Call Point

660 manual call points connect to addressable fire detection control and indicating equipment. Up to 125 devices can be connected to each alarm zone loop using the addressable loop communications protocol. A pressure-activated displacement element provides a safe and convenient way for building occupants to manually initiate a fire alarm condition. All models have an integral alarm indicator that illuminates when the manual call point has been activated. The indicator can also be configured to flash when polled by the fire detection control and indicating equipment. Resetting the manual call point is achieved by inserting a key through the underside of the unit to replace the operating face to the quiescent position. The 660 manual call point range provides fire detection and alarm system designers with a Standards-compliant, premium product for life safety and property protection applications.


Numens - intelligent photoelectric smoke detectors

SNA-360-SL analogue addressable photoelectric smoke detectors are microprocessor controlled state-of-the-art detectors suitable for connection to Numens addressable fire detection control and indicating equipment. Up to 125 detectors can be connected to each alarm zone loop. Advanced electronics in conjunction with a photoelectric smoke sensing chamber provides early detection of fire and high immunity against unwanted alarms. The SNA-360-SL analogue addressable detector range provides fire detection and alarm system designers with a premium smoke detector for life safety and property protection applications.