Canister Samplers

ATEC - Model 8001 - Manual Device for Canister Sampler System

The Model 8001 is a manual device known for its reliability and efficiency in its designated application. It`s designed to provide robust performance requiring minimal maintenance. The machinery features an intuitive manual interface, allowing users to operate without the need for complex programming or automation. This makes it suitable for operations where direct interaction and control is critical, particularly in environments where automated or electrical power solutions might be unsuitable. The product is engineered to withstand demanding conditions, offering durability and longevity. Technicians and engineers may appreciate its straightforward configuration, enabling swift integration into existing workflows. Its design ensures adaptability across various sectors, highlighting the product`s versatility in diverse industrial applications.

ATEC - Model 2200 - Manual Device for Canister Sampler System

The Model 2200 Manual is likely a robust and versatile tool designed for technical applications requiring precise manual operations. While exact specifications are not provided, manuals like the Model 2200 typically enable users to handle intricate tasks with accuracy. It may be part of an equipment line intended for specific industrial or field use where manual intervention is necessary. The design is likely optimized for ease of use, ensuring reliable performance even in demanding scenarios. Its utility can span various sectors, including engineering, manufacturing, or other domains where manual control and nuanced task handling are essential. In such environments, the Model 2200 Manual would be an essential tool aiding technicians, engineers, or operators to perform detailed work effectively.

Cartridge Samplers

ATEC - Model 8000 - Manual Cartridge Sampler System

The Model 8000 Manual is a detailed guide specifically designed for users who operate the Model 8000. It provides comprehensive instructions and insights into the setup, operation, maintenance, and troubleshooting of the Model 8000. The manual is crafted to cater to a technical audience, ensuring that engineers and technicians have access to precise and accurate information necessary for optimal operation. Covering various technical aspects, the manual outlines step-by-step procedures, safety precautions, and best practices to enhance performance and longevity. It serves as an invaluable resource for anyone needing a deeper understanding of this particular model, ensuring that users can efficiently address potential challenges and maximize the utility of the Model 8000.

ATEC - Model 2200 - Manual Carbonyl Air Sampler System

The Model 2200 manual is designed for users looking to gain a comprehensive understanding of this product`s specifications and operational capabilities. This manual provides detailed instructions on the setup, operation, and maintenance of the Model 2200, highlighting its key features and functionalities. Typically, the Model 2200 is a high-precision equipment used in technical applications, and this document offers insights into its advanced design and engineering. It covers critical areas such as system configuration, diagnostic procedures, and troubleshooting tips, supporting users in maximizing the efficiency and performance of the product. With its technical focus, it serves as an essential guide for technicians and engineers who need to ensure optimal use and longevity of the Model 2200.

Hexavalent Chromium (Cr6) Filter Samplers

ATEC - Model 3400 - Toxic Air Sampler System

The Model 3400 Toxic Air Sampler is designed to sample both toxic gases and particulates using one easy to use instrument. The Model 3400 can be ordered with up to 4 sample channels. The sample is ideally suited for use in the NATTS program, since it can simultaneously sample one canister, one carbonyl DNPH cartridge, and two hexavalent chromium (Cr6) filter samples. The sampling methods employed in the Model 3400 follow the guidelines outlined in EPA Methods TO-11A, TO-14, TO-15, and the improved CARB method for Cr6 recently developed by EPA and ERG. The flow rate through each channel is regulated with reliable mass flow controllers. A single board internal computer with a color touch screen display provides flexible scheduling, error checking, and data logging capabilities. The sampler is available in either an indoor or outdoor version.

Toxic Air Samplers

ATEC - Model 2200 and 2200-2 - Toxic Air Sampler System

The ATEC Models 2200 and 2200-2 Toxic Air Samplers are self-contained air sampling instruments that have been specifically designed to simultaneously collect air samples into canisters and sorbent cartridges for specified time periods. This provides the capability of obtaining both VOC and carbonyl measurements at the same time with one easy-to-use instrument. The flow rates into the canisters and cartridges are regulated using electronic mass flow controllers. A single board internal computer with a color touch screen display provides flexible scheduling, error checking, and data logging capabilities. These samplers can be configured for either sub-ambient or pressurized canister sampling as well as collocated sampling of either canisters or cartridges using independent mass flow controllers. Multi-port expansion units can be added to provide additional canister and cartridge sampling.

Others

ATEC - Custom Samplers System

ATEC has designed and manufactured a variety of custom samplers for unique sampling needs of many clients. Samplers Used in California Acid Deposition Monitoring Program. Aerosol Production Apparatus for Pharmaceutical Products.