Fire and Gas Detection Systems - Autroprime 2 Panels

Autronica - Fire Alarm Control Panel

Full fire detection system with 2 loop drivers each controlling 127 devices. The operator panel may be mounted remotely with redundant connections both for signal and power. The panel serves as a stand-alone panel. A maximum of 8 additional panels can be freely mixed and connected to the fire alarm control panel via the RS-485 panel bus, including repeater panels BS-211, information panels BV-210, fire brigade panels BU-210 and mimic drivers BUR-200.

Fire and Gas Detection Systems - AutroSafe 4 Panels

Autronica - Fire Alarm Control Panel

BS-420 is a complete fire alarm control panel with full operation capabilities. The panel serves as an operating panel for one or several defined operation zones. All alarm handling and system features can be controlled and monitored from the panel. The panel can accommodate up to a maximum of 12 modules. The system offers loop driver modules for detection loops and several types of input and output units. There can be a maximum of 6 loop driver modules in each panel. All modules are easily plugged onto each other on a standard mounting rail inside the unit. The panel provides connections for 2 Ethernet ports and 2 USB host ports. The panel is menu operated on a 16-line display, with 40 characters per line. A built-in printer is available as an option. The panel communicates with other system units on the Ethernet-based local area network, AutroNet.

Fire and Gas Detection Systems - AutroSafe 4 Integrated Fire and Gas (IFG) Panels

Autronica - Operator Panel Controls and Handles

The operator panel controls and handles all operations, alarm management, indications and other functions within an operation zone. No loop driver, input or output modules can be connected to this panel. The panel communicates with controllers and the entire system via the Ethernet-based local area network; AutroNet.

Fire and Gas Detection Systems - AutroSafe 4 Maritime Gas (MG) Panels

Autronica - Maritime Gas Alarm Control Panel Kit

A maritime gas alarm control panel with full operation capabilities. All gas alarm handling and system features can be controlled and monitored from the panel. Note that the panel cannot be used for detection of fires. The panel communicates with other system units on the Ethernet-based local area network, AutroNet. The maximum number of system units supported by AutroNet depends on the type of system. In a standard system the maximum number is 64. The panel can accommodate up to a maximum of 12 I/O modules. All modules are easily plugged onto each other on a standard mounting rail inside the unit. The fire gas alarm control panel kit includes a cabinet with a panel front, power supply module, communication module and text foils.

Fire and Gas Detection Systems- Detectors - Multicriteria Protector Series V-430

Autronica - Multicriteria Protector

Basic smoke/heat detector, no alarm device. AutroGuard® V-430 multicriteria protector provides a new generation technology that simplifies installation and commissioning, and increases fire safety. Extreme sensor dynamics provide reliable detection that has greatly reduced detection time and nuisance alarms, and expanded the use to cover even more application areas. The type of operation is configurable to Heat, Optical or Multisensor, covering several applications. 
It has a wide range of fire safety features included in one single device, providing significant reduction of wiring and installation costs - and a cleaner look.

Fire and Gas Detection Systems- Detectors - Multicriteria Protector Series V-530

AutroGuard - Multicriteria Protector System

Basic smoke/heat detector, no alarm device. Intrinsically safe for zone 0, 1 and 2. AutroGuard® V-530 is a multicriteria protector series. It provides a new generation technology that simplifies installation and commissioning, and increases fire safety. The Ex ia version is intrinsically safe for zone 0, 1 and 2. Please note that ATEX / IECEX / CSA / INMETRO must be spceified upon ordering. Extreme sensor dynamics provide reliable detection that has greatly reduced detection time and nuisance alarms, and expanded the use to cover even more application areas. The type of operation is  configurable to Heat, Optical or Multisensor, covering several applications. It has a wide range of fire safety features included in one single device, providing significant reduction of wiring and installation costs - and a cleaner look. The self-sensing technology ensures that the protector is as reliable as when it left the factory for its entire life cycle.

Fire and Gas Detection Systems- Flame Detectors - Single IR Flame Detectors

AutroFlame - Single IR Flame Detector

AutroFlame X98AF single IR flame detector in stainless steel housing. Relay and 4 - 20 mA, Certified Ex d e IIC T5-T6. Ingress protection level: IP66. Swivel mount not included. Approved to FM 3260 (2000), the X98AF meets the most stringent requirements worldwide with advanced detection capabilities and immunity to extraneous sources, combined with a superior mechanical design.

Fire and Gas Detection Systems- Flame Detectors - Dual IR Flame Detectors

AutroFlame - IR Flame Detector

BG-201 is an interactive point flame detector for detection of fires involving combustion of carbonaceous materials. The detector has a high IP rating making it suitable for the harshest environments. Advanced digital signal processing algorithms ensure fast detection of real fire scenarios combined with high immunity against nuisance alarms. Principle: Two infrared sensors detect the infrared spectrum from a fire. The sensors evaluate different parts of the infrared spectrum using this information to verify that the signals correspond to the characteristics of a real flame.

Fire and Gas Detection Systems- Input and Output Units

Autronica - Extinguishing Control Unit

Unit for monitoring and control of extinguishing equipment. IP67. For AutroSafe/AutroSafe IFG only. Note that the extinguishing control application requires feedback within 10 seconds after the release of the extinguishing media to avoid a faulty release message. The unit has two monitored inputs: Input A: extinguishing media. Input B: trigger gas. If the system does not have trigger gas, input B can be disabled by connecting a 2k resistor on the terminals. In addition, the unit has one monitored relay output.

Fire and Gas Detection Systems - Manual Call Points - 300 Series with SelfVerify

Autronica - Standard Manual Call Point

Standard manual call point with SelfVerify function and LED indication. Approved according to EN 54-11 and EN 54-17 for indoor applications. The call point must be installed according to local regulations, which normally means along escape routes, landings and exits. The SelfVerify function ensures the highest grade of reliability and the lowest degree of manual testing because all units comprising this function are automatically self-tested once every 24 hours. Part number: 116-BF-300V2.