Burt Process Equipment, Inc. (BPE) products
Assured Compliance System (ACS) - Model Continuous Flow and Batch Treatment - Acid Waste Neutralization System
Our Assured Compliance System (ACS) is a prepackaged, skid mounted pH adjustment system, designed for use as a wastewater treatment process. This pH neutralization system uses our proprietary “hybrid batch technology” to treat continuous flow streams. High efficiency proportional metering pumps, multi-chamber treatment tank, passive equalization chamber, wet-tap with self-cleaning pH probe and heavy-duty gear mixer are all standard. The ACS series units use recirculation loop reagent injection and offer a large retention volume. The system was developed by Burt Process Equipment, a worldwide leader in pH neutralization systems for more than 45 years. The ACS series for pH adjustment accepts a continuous flow of wastewater at flow rates of up to 300 GPM with a pH of 2-12.
pH Plus Family - Model PHX 100 - PHX 500 - pH Adjustment Systems
The pH Plus is a continuous flow pH neutralization system, handling flow rates up to 50 GPM and pH levels of 4-12. pH Plus neutralization systems are completely integrated, prepackaged systems provide automatic acid neutralization of waste water in industrial environments, using pH adjustment chemicals. They feature advanced instrumentation and controls for easy installation and the highest level of reliability. The compact design provides a smaller footprint and lower cost for installation. They can also be customized for batch pH adjustment when the machine is run manually or with automatic batch controls, available as an option. The PHX-100, PHX-200, PHX-300, PHX-400 and PHX-500 models differ in terms of continuous flow capacity, mix tank volume and reagent pumps capacity.
Lab Master - pH Adjustment Systems
Our Lab Master series of pH adjustment systems is engineered for the hard to adjust low ion waste streams frequently found in laboratories and semiconductor facilities that handle chemicals high purity water and chemicals. This system uses a pre-treatment feed system for fast, accurate pH adjustments during a wastewater treatment process, without the need for pH oscillation. If the waste material that you’re processing has a large amount of high purity or deionized water, the Lab Master is an effective pH neutralization system.
Spec Master family - pH adjustment systems
Spec Master family of pH adjustment systems is engineered to meet the most demanding specifications for quality and performance. Our Spec Master BPSM units use components of the highest quality for optimal durability and reliability during a wastewater treatment process. They’re custom built to your requirements and engineering specifications. Our custom modifications are based on proven designs that conform to each customer’s application and corporate standards. All components we use in the Spec Master line of ph neutralization systems are “Best of Class.” We have designed, engineered, installed, implemented and maintained Spec Master systems for many Fortune 500 businesses in the semiconductor, metal finishing and pharmaceutical industries.
pH Neutralization Systems
Burt - Industrial pH Adjustment System
An industrial pH adjustment system, as a part of wastewater treatment, controls pH by the automatic addition of acid or caustic reagent until the pH is within the desired range to meet wastewater discharge regulations. The pH Adjustment Systems from Burt Process Equipment are custom engineered, prepackaged and fully integrated units designed for automatic pH neutralization and wastewater treatment. They feature advanced instrumentation and controls for easy installation and the highest level of reliability. The compact design provides a smaller footprint and lower cost for installation. This allows for greater overall efficiency and cost-effectiveness for your company’s wastewater treatment process.
Burt - Model ACS - pH Adjustment Systems-Assured Compliance
pH Adjustment Systems control a pH level in the industrial wastewater treatment by injecting the acidic or basic chemicals to neutralize the pH. The pH adjustment system is one of the important elements for treating wastewater in an industrial facility or laboratory. Each industrial facility or laboratory has an effluent permit that dictates the permissible pH level of the wastewater discharge. The pH neutralization system’s facility requirements depend on the properties of the wastewater you are disposing of, as well as the amount of wastewater your facility processes. The two primary factors for pH neutralization system design are the flow profile and the nature of the waste.
Pump Lift Stations
Burt - Simplex Lift Station Units
Simplex Lift Station units are the one pump standard option for the proven solution for your pump lift station needs. Simplex Pump Lift Stations are used for applications where pump redundancy is not required. Simplex Pump Lift Stations are completely automated and designed to handle the most aggressive chemical solutions in plating, waste treatment, semiconductor and biotech applications. Simplex tank units range from 7 to 50 gallons. Simplex Pump Lift Station tanks are available in two plastics, High-Desnsity Polyethylene (HDPE) Simplex Pump Lift Stations or natural Polypropylene Simplex Pump Lift Stations. Simplex Lift Station covers are 1/2" thick bolt-down Polypropylene. Most Simplex Lift Station units are off-the-shelf and can often be shipped the same day.
Burt - Duplex Lift Stations Units
Duplex Lift Stations units are the two pumps standard option for the proven solution for your pump lift station needs. Duplex Pump Lift Stations are used in cases when pump redundancy is required for high inlet flow conditions and to eliminate downtime. Duplex Lift Station units come standards with alternating pump controls to even out wear and promote longer pump life. When flow into the system spikes and the level rises above the normal pump turn-on setting, the system will trigger both pumps to run simultaneously until level returns to the pump turn-off setting. Optional high-level alarm sounds when liquid level rises above the second pump turn-on setting.
High Purity RODI System
Burt - High Purity Reverse Osmosis Deionization Systems
A high purity water system is a prepackaged unit designed to generate, store, and distribute ultrapure water for use in biotech, pharmaceutical, food & beverage, industrial manufacturing, academic and institutional processes. The PurePlus family of RODI water systems are skid mounted and built to be the most cost-effective and easy-to-install ultrapure water systems on the market today. If you`re looking for a durable, easy to operate, reverse osmosis deionization system that provides remote access through state-of-the-art technology, click here to request a free engineering consultation.
Chemical Feed Systems
Burt - Model Simplex - Wastewater Treatment Chemical Dosing Systems
Chemical Feed Systems (Chemical Dosing Systems) inject chemicals into a waste stream to adjust pH, remove unwanted dissolved or suspended solids, and assist with final water purification. Almost all wastewater treatment processes incorporate chemical feed systems.