Carltex International Inc. products
Model Series 400 - Data Acquisition System
The SERIES 400 system, with SCAN 1000, is an integrated hardware and software package for data acquisition and supervisory control using personal computers. The flexibility, ease-of-use and power of the system has been proven in a range of applications including: Autoclave monitoring and validation. Environmental chamber monitoring and validation. Drug and food storage trials. Heat treatment monitoring. Battery life testing. Engine and automotive component testing. Pilot plant monitoring. Air conditioning and central heating product testing. White goods - domestic and commercial refrigeration product test. White goods - domestic and commercial cookers, stoves and heaters product test. Pump and compressor test. Bearing test. Building management system validation.
MadgeTech - Model HiTemp150 - Extended Range Temperature Data Logger
The HiTemp150 temperature logger is a rugged, submersible, battery powered, stand alone device which can be used to automatically record temperatures between -40 and 150°C. This all in one compact, portable, easy to use device is able to measure and record up to 32,767 temperature measurements. The HiTemp150 features a 2” rigid external probe with fast response time to ensure accurate temperature readings and is ideal for use in harsh environments. Its real time clock ensures that all the data is time and date stamped. The storage medium is non-volatile solid state memory, providing maximum data security even if the battery becomes discharged. The device can be started and stopped directly from your computer and its small size allows it to fit almost anywhere. The HiTemp150 makes data retrieval quick and easy.
MadgeTech - Model HiTemp150FP - Extended Range Temperature Data Logger With Flexible Probe
The HiTemp150FP is a small, rugged, reusable temperature data logger specifically designed for deployment in harsh environments. The HiTemp150FP comes standard with a 24` flexible silicone rubber enclosed cable, 4` penetration style stainless steel probe, and 316 stainless steel body (other cable and probe lengths available through special order). With measurement range of -40°C to +150°C, the HiTemp150FP is perfect for use in autoclaves, medical and pharmaceutical labs, food preparation and processing plants, dishwashers, and other applications involving extreme temperatures.
Model SQ1 - Steam QualityTest Kit
The SQ1 Steam Quality Test Kit has been designed to comply with EN 285 with a single improvement to the methodology. It should be noted at the outset that EN 285 specifically allows alternative procedures, provided that they have been calibrated against the standard methods. Instead of the non-condensable gas test being as described in the standard, we provide a condenser system which we have found to be safer, more robust, easier to use (less subjective), and more repeatable. The objective is to separate non-condensable gases from steam and the disadvantage of the standard method is the subjective adjustment of steam flow to prevent localized boiling and therefore the collection of non-condensable gases from the water being used to condense the steam. By using a condenser, the steam does not come into contact with the water and eliminates this subjective and variable aspect.
SQ2 Sanitary Sample Cooler
Designed specifically for taking high quality chemistry, TOC and microbiological samples from steam or heated recirculating water systems with minimal risk of contamination. The use of high quality materials reduces the risk of sample contamination. All sample contact surfaces are electropolished 316L stainless steel with Ra 0.25 µm (10 µin) surface finish. The heat exchanger coil is self-draining and highly efficient as a result of the integral cooling water baffle. Fully traceable materials are used – a full certification package is provided with each cooler. 100% 316L stainless fabrication with external mirror polish finish. Easily cleaned and compact sanitary design to allow it to be located in clean areas (option for tri-clamp connections for cooling water). The compact design requires a minimum of space. Sample outlet suitable for flaming. Designed for either wall mounting using integral 316L stainless steel brackets with space to allow cleaning behind, or for portable applications where folding legs are provided. Both fixed and portable models are designed to be steam sterilized (or dry heat sterilized/depyrogenated). Portable cooler and folding legs are supplied in a tough ABS case for ease of carrying.Metrel Indoor Environmental / Air Quality Measurement
Universal all-in-one instrument for measurement of air temperature, air velocity, relative humidity, illluminance, luminance and the Class 1 (Pro Set) or Class 2 (Euro Set and Standard Set) sound analyses. luminance measurement, contrast, globe temperature, thermocouple (contact temperature), PMV (predicted mean vote), PPD (predicted percentage of dissatisfied), WBGT (wet bulb globe temperature).MicroLog Temp/Humidity Low-Cost Data Loggers
Whether your product is vegetables, medical supplies, ice cream or industrial chemicals. Whether you need to transport your products by air, land, or sea. Whether your goods travels for hours or weeks, MicroLog will ensure that they are being transported under the proper conditions at all times. Two built in quality sensors for monitoring temperature and humidity, and an additional external sensor for adding the sensor of your choice, a memory capacity of 16,000 measurements, and a 2 digit display make the MicroLog the most innovative and powerful device in the market.SENTINEL Chart Recorders/Controllers
Sentinel combines the simplicity and clarity of pen drawn traces together with the versatility of microprocessor control.The Sentinel range of microprocessor-based circular chart recorders is available in 1, 2 or 3 channel versions. Each channel is equipped with a universal signal input which is compatible with all industry standard sensors and signals including thermocouple types J, K, T, E, N, R, S and B, PT100 platinum resistance temperature detectors and 4/2OmA current loops. Low and high measurement ranges are provided for each input type, separate range cards are not required. Multipen versions include opto-electronic isolation of the input stages to eliminate troublesome installation ground loops. Available in 1, 2 or 3 pen versions, User configurable via front-panel keypad, Easy-to-use menu-driven software for rapid configuration and calibration, Universal input accepts thermocouples, RTDS, Vdc and mAdc, Large-character alphanumeric display panel with backlight, High accuracy and stability, Simultaneous digital display of process variable for each channel, Special `Zoom` feature for expansion of range, Microprocessor control of ranging, relays, chart speed and sensor linearization, Comprehensive alarm facilities, Alarm status shown by colour-coded LEDs, Hardware and programmable software locks for security, Slim case ideal for shallow compartments, Simple installation and low maintenance.