ELVEM
8 products found

ELVEM products

Ovens

Uniclave - Model 99 - Vertical Steam Sterilizer

75, 127 and 157 liters. Stainless steel inside and out. Analog temperature/pressure setting (optionally electronic). Safety systems for pressure, lack of water. Programmable sterilization cycles with automatic operation. 3.5” touch screen. Digital display of pressure and temperature.

Serum Heating Oven

Internal construction of stainless antimagnetic steel. Insulation from compressed stone wool panels. Door with silicone sealing gasket. Accelerated recirculation of hot air, with centrifugal pumps for uniform temperature distribution in the chamber. Stainless steel heating elements – air. Electronic digital thermostat – thermometer, with microprocessor (PID controller), digital timer (optional) with bypass switch for continuous operation. Safety thermostat. Overheating alarm. Indications for each operating parameter. External coating of galvanized sheet metal with special electrostatic paint. Temperature Range: 35°C/ 100°C.

Drying Ovens

Internal construction of stainless antimagnetic steel. External coating of galvanized sheet metal with special electrostatic paint. Insulation from compressed stone wool panels. Door with silicone sealing gasket. Accelerated hot air recirculation for uniform temperature distribution in the chamber. Heating stainless steel resistors. Electronic digital thermostat – thermometer, precision, with PID microprocessor, digital timer (optional) with bypass switch for continuous operation. Safety thermostat. Overheating alarm. Indications for each operating parameter. Temperature Range: 50 – 250°C. Temperature Recorder: Optional. Timer: Optional.

INOX Vacuum Sterilizer and Ovens

Air flow: Selectable/Optional. Electronic Thermostat: Yes. Digital temperature gauge: Yes. External Material: INOX. Interior Material: INOX. Overheat control: Yes. Indicator manometers: 1. Temperature recorder: Optional. Air vacuum pump: Yes. Timer: Optional. Orientation: Horizontal. Power: 1100W. Temperature indication analysis: 0.1°C. Temperature selection analysis: 0.1°C. Indication accuracy: 2%. Temperature stability: 2°C. Supply voltage: 230V.

Laboratory Refrigerators - Medicine Storage Refrigerators

Maintenance Chambers of Concrete Testing Equipment

Specifications: Electronic Thermostat: Yes. Digital temperature gauge: Yes. Stainless steel construction (inside-outside) 304-18/8: No. External Material: Galvanized steel. Interior Material: Galvanized steel. Overheat control: Yes. Shelves: 0. Supply voltage: 380V.

Laboratory Refrigerators

Inox Laboratory Freezer

Construction from stainless steel AISI 304 18/8-10. Injected polyurethane foam insulation, 60mm in thickness (CFC & HCFC free,42±2 Kg/m3 density). Tested Operation at ambient Temperature of +43°C. Ergonomic designed reversible doors with lock, 70mm thick with a self closing mechanism at an angle of 45o or less. Hygienically designed rounded corners. Clip-on shelving system. Automatic evaporation of the condensate water. Clip-on magnetic gaskets. Εquipped with a frame electric resistance. Refrigeration system: Ventilated.

Inox Laboratory Freezer with Glass Door

Construction from stainless steel AISI 304 18/8-10. Injected polyurethane foam insulation, 60mm in thickness (CFC & HCFC free,42±2 Kg/m3 density). Triple glazed Glass Door with self-closing mechanism at an angle of 45o or less and lock. Anti-fog film on the Glass panel of the door. Hygienically designed rounded corners. Clip-on shelving system. Automatic evaporation of the condensate water. Clip-on magnetic gaskets. Equipped with a frame electric resistance.

Chambers - Stability Rooms

Climatic Stability Chamber for ICH Stability Testing

For the study of ICH long term stability / ICH accelerated stability. The chamber is delivered to your location, ready for use. It operates autonomously and it only requires electricity, water and internet. Inside it is divided in three spaces. Lobby, main chamber, engine room.
The main chamber can be adjusted to different temperatures and humidity values. Depending on the needs of the experiments. Indicatively we mention the most common conditions: 25c/60%, 20c/60%, 23c/50%, 25c/40%, 20c/65%, 30c/40%, etc.