Enelsan Endustriyel Elektronik AS
10 products found

Enelsan Endustriyel Elektronik AS products

Flowmeters - Electromagnetic Flowmeter

Enelsan - Electromagnetic Flowmeter

Electromagnetic flowmeters can be easily used in all liquids with conductivity over 20 uS. They provide a realiable and long-lasting measurement opportunity by changing the sensor selection in liquids with corrosive properties according to different substances. The inner surface can be preferred as rubber or PTFE. The device, which allows density adjustment, flow unit adjustment, and temperature adjustment, can be used safely in different liquids with any density. The device menu is user-friendly and has 4 different encryption and security settings. Flow rate, conductivity and total working hours can be monitored on a single screen.

Enelsan - Model Hydra Series - Electromagnetic Flowmeter

The HYDRA Series electromagnetic flowmeter contains two coils. These coils, with the help of metal blocks placed on them, create a continuous magnetic field across the cross-sectional area of the measurement tube. Two electrodes that detect voltage are placed perpendicular to each other inside the measurement tube. The insulating material coated on the inner surface prevents the formation of short circuits between the conductive liquid and the metal measurement tube. When there is no flow, no electrical voltage is generated between the two electrodes. In the conductive liquid, negatively and positively charged ions are present in equal amounts. When flow starts, the magnetic field applies a force to the charged ion particles in the liquid.

Enelsan - Model 0XD - Electromagnetic Flowmeter

In order to be able to measure with high precision in conventional electromagnetic flowmeters, a straight pipe length of x5 diameter in front of the flowmeter and x2 diameter behind the flowmeter is required. In addition, valve outlet, elbow, etc. that may cause turbulence on this line. factors should not exist. With the 0xd Electromagnetic flowmeter, these difficulties are eliminated, and precise flow measurements can be made without the need for costly modifications on the existing line. There are no mechanical parts that prevent the flow or reduce the pressure. measurement scale.

Flowmeters - Ultrasonic Flowmeter

Enelsan - Ultrasonic Flow and Calories Measurement System

In order to provide high precision and accuracy in calorie measurement, the flow measurement method operating on the ultrasonic principle and temperature measurement with the PT100 temperature sensor are used. The main unit calculates calories by estimating the energy difference between the temperature sensors according to the flow rate it receives and the temperature difference between the 2 temperature sensors. Ultrasonic calorie measurement system manages to calculate calories in the following units.

Enelsan - Model EUF-200B - Fixed Type Ultrasonic Flowmeter

EUF-200B Ultrasonic flowmeter is improved for long-term online measurement with wide measuring range. It is produced as converter protection class IP67 and sensor protection class IP68. It is suitable for use in many liquid measurements. Ultrasonic flowmeters are flowmeters that take measurements from the outside of the pipe with high frequency sound.While the transmitter sensor of the flowmeter, which takes measurements with the help of 2 sensors, sends high frequency sound waves into the pipe, the receiver sensor determines the velocity of the fluid according to the reception of this signal. In pipes of different materials, measurements can be taken readly from outside the pipe. In this way, there is no need to intervene on the pipe.

Enelsan - Portable Ultrasonic Flowmeter

Ultrasonic flowmeters take measurements via the outside of the pipe with high frequency sound. While the transmitter sensor of the flowmeter, which takes measurements with the help of 2 sensors, sends high frequency sound waves into the pipe, the receiver sensor determines the velocity of the fluid according to the reception of this signal. In pipes of different materials, measurements can be taken easily from outside the pipe. In this way, there is no need to intervene on the pipe. They can take measurements from DN15 to DN6000 according to sensor sizes. The absence of an inner coating (concrete, fiberglass, etc.) in the pipes that these model flow meters will be used in, the fact that the pipes are not rusted, damaged, and their integrity is not impaired are important factors for measurement.

Level Measurement

Enelsan - Model EGLStx - Float Level Transmitter

EGLStx Level sensors are used for tank level and control. When the magnetic field of the magnet inside the float which moves along the tube according to the liquid level, is aligned with the reed sensor, there is electricity turns the circuit on or off.

Enelsan - Model EGLG - Magnetic Level Indicator

EGLG magnetic by-pass level indicators are mounted on the outer or upper surfaces of tanks, boilers and tanks. It gives the opportunity to see the level easily and with high accuracy.

Enelsan - Model EGCAP - Capacitive Level Transmitter

EGCAP level transmitters are capacitive level sensors used for level measurement in conductive liquids, low conductivity liquids, solid particulate and powdery materials, sticky and acid/basic liquids. When the material comes between the electrode rod and the tank wall, there is a capacity. It precisely measures this capacitance change and converts it to an analog signal. Full - empty calibration can be done easily and reliably.
Especially for machine manufacturers, different solutions are offered for industrial level measurement with different designs.

Enelsan - Model GCAS - Capacitive Level Switch

GCAS level switch is a capacitive level sensor used for level control in conductive liquids, low conductivity liquids, powdery materials with solid particles, sticky and acid/basic liquids. When the material comes between the electrode rod and the tank wall, there is a capacity change and when this change exceeds the set limit, the contact gives the output. It is designed for difficult process conditions. Refrigerated models can be manufactured for high temperature and pressure environments. Trigger point and relay operating range calibration can be done by the user under operating conditions.
It can be connected horizontally or vertically.