FST International H.C. Ltd.
10 products found

FST International H.C. Ltd. products

Powder Process & Characteristics

FST - Automatic True Density Analyzer

True density is one of the important parameters in measuring physical property of solid materials, especially powder. Value of true density depends on material purity and compactness which affect the quality of sample. The traditional measuring true density of materials is based on Archimedes water displacement method. As the serious inaccuracy of manual operation and drainage exists, ISO (the International Standard Organization) officially implemented gas displacement method (ISO 12154). Densi 100 Series True Density Analyzer can quickly and accurately produce true volume and true density of various solid materials such as powders and blocks. The sample chamber volume range is 1 cm³ - 100 cm³. It takes about 3 minutes to complete analyses without influencing accuracy.

FST - High Performace BET Surface Area and Pore Size Analyzer

The Micro Series can accurately produce surface area and pore size results of powder materials. According to the different test functions, this series of instruments are divided into three types, there are A, B, and C, the C type is configured with 1 torr or 0.1 torr high-sensitive pressure sensors and turbo molecular pump with ultimate pressure of 10-8 Pa, it can effectively take microporous analysis of microporous materials such as molecular sieve, catalyst, activated carbon, and other microporous materials.

FST - High Performance Glow Discharge Mass Spectrometers (GDMS)

The main focus of MSI is high resolution glow discharge mass spectrometry (GDMS); a mature, versatile technique for the direct determination of elemental content (matrix to sub-trace) in a variety of materials.

Xigo - Nanoparticle Surface Area Measurement Device

The Acorn AreaTM is a revolutionary instrument designed to measure the surface area of nanoparticles dispersed in a liquid. This patented nuclear magnetic resonance based method offers many advantages in comparison with conventional surface area techniques. Measurements take about 5 minutes from start to finish. No sample preparation such as drying or degassing is required. High concentration dispersions are measured directly; without dilution. Acorn Area measurements are orders of magnitude faster than any other surface area measuring technique.

FST - Nano Particle & Zeta Potential Analyzer

Size range : 1 nm - 5um; Zeta potential size range : 0.02 - 20 um; Sample volume : 1 mL - 1.5 mL; PH range : 2--12; Conductivity range : 10-5 S / m - 0.2 S / m; Particle detection angle : 12 - 150 ° (Default angle 90 °); Zeta potential detection angle : 19 °.

Process Control and Analysis

FST - Mobile VOC Gas Analyzer

The DV3000 is a real-time, portable analysis unit, capable of simultaneously measuring fourteen pollutant gases using ultraviolet spectroscopy. Proprietary software and algorithms analyse real-time readings and generate ppb concentration levels, typically every second per species.

FST - Proton Transfer Reaction Quadrupole Mass Spectrometry

Main specifications:; Mass resolution: less then 1 amu; Reaction time: less then 100 ms; Quality Range: 1- 512 amu; The linear range: 1 pptv - 10 ppmv; Real-time monitoring changes in VOC concentrations in air.

FST - Proton Transfer Reaction Time of Flight Mass Spectrometry

Main specifications :; Mass resolution : > 1-10000 m / ? m (FWHM); Reaction time : less then 100 ms; Quality range : 1-10,000 amu; The linear range : 10 pptv - 1 ppmv; Real-time monitoring changes in VOC concentrations in air.

FST - Online Nano Particle Analyzer

Particle size measurement range : 0.15 - 20um; Measurement time : 10sec ~ 3min; Information channels : 8 to 32 channels; Flow control : 15 mL / min; Particle size error rate : <15%.

FST - Online Auto Titrator (Integrated System)

Analysis : potential method / standard addition method / photometric method; Accuracy : +/- 0.2% of the displayed value; Accuracy : +/- 0.2% relative error; Measuring time : less then 5min / each measurement; Sample : about 0.05 ~ 5ml (depending on application); Sample temperature : up to 200 ? (93 ?); Water consumption ratio : 250ml / each measurement; Sample inlet pressure demand : less then 30PSI; Deionized water inlet pressure requirement : 20-40PSI; CDA inlet pressure demand demand : 60-80PSI; Power supply : 110/220 VAC, 50 / 60Hz, 1 / 0.5A (Field Switching); Exhaust : 1.875 "OD @ 17CFM; Machine Size (inches) : 34.00 "high x 13.50" wide x 13.00 "deep; It can be customized for various types of chemical concentration measurement.