- Home
- Companies
- Ionode Pty Ltd.
- Products
Ionode Pty Ltd. products
Electrodes for Electrochemistry
Ionode - Pt Auxiliary / Counter Electrode
Dimensions: 85mm length x 6mm diameter. Pt area 6.5x6.5x0.2mm. Ionodes Platinum Auxiliary / Counter Electrode have a large surface area, extra thick platinum for enhanced strength, glass body and a gold plated pin.
Ionode - Working Electrode
Working Electrode - Glassy Carbon 3mm Diameter - PEEK Body. Body: PEEK. Tip: Glassy Carbon. Disc Diameter: 3mm. Purity: 99.99%. Dimension: 6mm Diameter x 65mm Length. Each electrode is polished and tested with CV before shipping. Length can be modified to suit your application.
Ionode - Working Electrode
Working Electrode - Gold 3mm Diameter - PEEK Body. Body: PEEK. Tip: Gold. Disc Diameter: 3mm. Purity: 99.99%. Dimension: 6mm Diameter x 65mm Length. Each electrode is polished and tested with CV before shipping. Length can be modified to suit your application.
Ionode - Working Electrode
Working Electrode - Platinum 3mm Diameter - PEEK Body. Body: PEEK. Tip: Platinum. Disc Diameter: 3mm. Purity: 99.99%. Dimension: 6mm Diameter x 65mm Length. Each electrode is polished and tested with CV before shipping. Length can be modified to suit your application.
Intermediate Junction Series
Ionode - IJ40A Intermediate Junction pH Electrode
Body: Polypropylene. Temp Range: 0 -60°C. pH Range: 0 -12 pH. pH Sensor: A Glass Bullet. Reference: Double Junction Ag/AgCl/Sat KCl Gel. Slope: >98%.
Ionode - IJ40C Intermediate Junction pH Electrode
Body: Polypropylene. Temp Range: 0 -60°C. pH Range: 0 -14 pH. pH Sensor:C C Glass Bullet. Reference: Double Junction Ag/AgCl/Sat KCl Gel. Slope: >98%.
Ionode - Intermediate Junction ORP Electrode
Body: Kynar. Temp Range: 0 - 100°C. ORP Range: ±2000mV. ORP Sensor: Platinum. Reference: Double Junction Ag/AgCl/Sat KCl Gel. Cable Length: 1m. Standard (Max. 20m). Connector: BNC Standard. Notes: General purpose high Temp ORP electrode. Dimensions: 12mm x 120mm.
Refillable Electrodes
Ionode - Refillable pH Electrode, pH 0 - 12
Body: Polypropylene. Temp Range: 0 -60°C. pH Range: 0 -14 pH. pH Sensor: A Glass Bulb. Reference: Single Junction Ag/AgCl, saturated refillable KCl. Slope: >97%. Zero pH Value: 7.0 ± 0.5. Cable Length: 1m. Standard (20m Max). Note: Three ceramic frits - very fast response time.
Ionode - Refillable pH Electrode, pH 0 - 14
Body: Polypropylene. Temp Range: 0 -60°C. pH Range: 0 -14 pH. pH Sensor: C Glass Bulb. Reference: Single Junction Ag/AgCl, saturated refillable KCl. Slope: >97%. Zero pH Value: 7.0 ± 0.5. Cable Length: 1m. Standard (20m Max). Note: General purpose refillable pH electrode.
Sealed Gel
Ionode - Sealed Gel
Body: ABS. Temp Range: 0 - 60°C. ORP Range: ±2000mV. ORP Sensor: Platinum (Gold on request). Reference: Single Junction Ag/AgCl Gel. Cable Length: 1m. Standard (Max. 20m). Connector: BNC Standard.