18 products found
Kimessa AG Products
-
Gas Monitor
-
DUOline - Control Unit
The control unit DUOline is designed for connecting one or two gas sensors. Depending on the specific gravity of the gas to be detected, the gas sensors are mounted at the ceiling or 20 cm above the floor. For controlling toxic gases and oxygen, the individual sensors are available as standard and Ex protection type sensors. The pre-alarm (PA) is self-resetting; depending on the program the main alarm (MA) is also self-resetting or has to be reset ...
-
CANline - Analogue & BUS Gas Monitor Panel
The CANline A control unit displays the detector gas concentration with name and location. The CANline A may be connected to a total of 32 sensors along with remote displays and 6 off relay cards.Maximum of 32 relays may be connected to the CANline A.The SELECT button can be used for selecting several modes of display.PEAK reading or sequential scannin g.The integrated timer may be used for periodic switching of relays, e.g., to activate local ...
-
CANline - BUS Gas Monitor Panel
32 BUS sensor inputs (sensors type KSxC, KSIM).Digital display indicates the gas concentration in ppm or % LEL.4 gas alarm thresholds indicated on the digital display.8 potential free relays contacts 2A 230VAC.max. 6 CANline -Relay Cards with 4 free relays outputs per card.Relay on and off time delay programming option (each relay is programmable).Timer for periodic ventilation in an indoor car park.Relays: Manual or auto reset, manual reset override, ...
-
Gas Detector
-
Model GSE 307 - Gas Sensor
The principle of the measurement cell used is based on the electro-chemical oxidation of hydrogen H2 on the working electrode. The H2 in the measurement air reaches the working electrode via a gas-permeable diaphragm, and is oxidised. The oxygen molecule used for this is replaced from the ambient air. This results in the very long service life of the measurement cell, which, from experience, can operate for several years. The measured gas concentration ...
-
Model GSE 401 - Gas Sensor for Detection of Oxygen O2
The principle of the measurement cell used is based on the diffusion of oxygen. The O2 diffuses through the gas-permeable diaphragm onto the gold cathode, and is reduced on it. The current flowing between the electrodes is proportional to the concentration, and will then be amplified and be led to the evaluation device by the transmitter. The measured gas concentration is linear to the electrical output signal of the gas measurement probe. The ...
-
Model GSE 507 - Gas Sensor for Detection of Carbon Monoxide CO
The principle of the measurement cell used is based on the electro-chemical oxidation of carbon monoxide CO to carbon dioxide CO2. The CO in the measurement air reaches the working electrode via a gas-permeable diaphragm, and is oxidised. The oxygen molecule used for this is replaced from the ambient air. This results in the very long service life of the measurement cell, which, from experience, can operate for several years.The measured gas ...
-
Model KSEA 504 - Gas Sensor
The principle of the measurement cell used is based on the electro-chemical oxidation of carbon monoxide CO to carbon dioxide CO2. The CO in the measurement air reaches the working electrode via a gas-permeable diaphragm, and is oxidised. The oxygen molecule used for this is replaced from the ambient air. This results in the very long service life of the measurement cell, which, from experience, can operate for several ...
-
Model KSEA 517 - Gas Sensor
Through the diffusion of ammonia NH3 into the inside of the measurement cell, a reaction with the electrolyte will take place. The product at the working electrode then oxidises. The electrolyte regenerates after the removal of the ammonia gas. In the case of long periods at a high gas concentration, the measurement cell can become saturated, which leads to a signal reduction until the electrolyte has ended the oxidation at the working electrode. The ...
-
Model KSEA 627 - Gas Sensor
Through the diffusion of hydrogen sulphide H2S into the inside of the measurement cell, a reaction with the electrode will take place. The product at the working electrode then oxidises. The oxygen molecule used for this is replaced from the ambient air. This results in the very long service life of the measurement cell, which, from experience, can operate for several years. The measured gas concentration is linear to the electric output signal of the ...
-
Model KSEA 637 - Gas Sensor
Through the diffusion of sulphur dioxide SO2 into the inside of the measurement cell, a reaction with the electrode will take place. The product at the working electrode then oxidises. The oxygen molecule used for this is replaced from the ambient air. This results in the very long service life of the measurement cell, which, from experience, can operate for several years. The measured gas concentration is linear to the electric output signal of the ...
-
Model KSEA 657 - Chlorine Gas Sensor
Chlorine gas diffuses into the sensor and reacts at the sensing electrode on the surface of the electrode. The counter electrode acts to balance out the reaction at the sensing electrode by reducing oxygen in air to water. The oxygen from the ambient air diffuses at the back side into the sensor. A high reserve of electrochemical activity ensures that each sensor has a long life time (see performance characteristics) and excellent temperature ...
-
Alarming Units
-
CANline - Model CWE 67 - Alarm-Unit
The KIMESSA CWE 67 is a unique BUS compatible audio visual alarm designed for use with the addressable CANline gas monitoring solution. The flash light could be delivered in different colours, e.g. orange for explosive gases or blue for toxic gases. The housing consists of powder-coated steel. The flash light is constructed for mounting inside of ...
-
CANline - Model CWE 58 - Audio Alarm Unit
The KIMESSA CWE 58 is a unique BUS compatible audio alarm designed for use with the addressable CANline gas monitoring solution.The CWE 58 is typically used in underground car parks together with the Gas Warning LED display, type LW 260 or LW 1102. The housing consists of powder-coated steel. The audio alarm is constructed for mounting inside of ...
-
Gas Monitoring Systems
-
MONOline - Gas Monitoring System
The MONOline monitor displays the detector gas concentration with name and alarm status. The monitor is factory calibrated and ready to use. 24VDC or 230VAC power supply. Wall mounting. Internal sounder alarm. Incorporated LED Flash-Light. Alarm status clearly visible on the OLED- Display. Robust IP 65 enclosure. 3 internal relays available to activate ventilation fans or alarming units. Different relay functions programmable (Reset manual or ...
-
CANline - Model 01 - 1-Channel Gas Monitor
The CANline 01 control unit displays the detector gas concentration with name and location. The CANline 01 may be connected to a total of 1 sensors along with 4 of relay cards. The SELECT button can be used for selecting several modes of display. The integrated timer may be used for periodic switching of relays, e.g., to activate local fans in the monitoring zones at set times in the day. For wall or cabinet mounting in a front door of a control ...
-
Gas Detectors
-
MONOline - Gas Detector System
The MONOline monitor displays the detector gas concentration with name and alarm status. The monitor is factory calibrated and ready to use. 24VDC or 230VAC power supply. Wall mounting. Internal sounder alarm. Clearly visible flashing beacon alarm (optional). Alarm status clearly visible on the OLED- Display. Robust IP 54 enclosure. 3 internal relays available to activate ventilation fans or alarming units. Different relay functions programmable (Reset ...
-
Model 4-20 mA Output - Gas Detector
The gas detector measures the selected gas concentration. linearized and temperature-compensated 4-20mA output signal. 16…30VDC supply voltage (2-wire or 3-wire cable). various gas sensor technologies available (electrochemical, Infrared, pellistor, semiconductor). factory calibration with calibration certificate to the specified measuring range. Zero & Span potentiometers and calibration jack socket accessible from outside without opening ...
-
Portable Gas Monitors
-
Kimessa - Model SKC - Single Clip Portable Gas Monitor
Whether it’s the hottest environment or the coldest, our Single KIMESSA Clip is designed and tested to provide worker safety in the harshest working conditions. There are no hidden service charges, no maintenance fees– just reliable units that will help your facility workers and contractors do their jobs safely, productively and cost ...