LINSEIS Messgerate GmbH products
Thermal Analysis - Dynamic differential calorimeter - DSC
LINSEIS - Model Chip-DSC 10 (Chip-DSC L66 Advanced) - Dynamic Differential Calorimetry
The Chip-DSC 10 (Chip-DSC L66 Advanced) integrates all essential parts of the DSC, heater, sensor and electronics in a miniaturized housing. The chip arrangement consists of a heater and temperature sensor in a chemically inert ceramic arrangement with a metallic heater and temperature sensor. This arrangement enables high reproducibility and, due to the low mass, excellent temperature control and heating rates of up to 300 K/min. The integrated sensor is easily replaceable and available at low cost. The integrated design of the chip sensor provides excellent raw data, allowing direct analysis without pre- or post-processing of the heat flow data.
LINSEIS - Model Chip DSC 100 (Chip-DSC L66 Ultimate) - Dynamic Differential Calorimetry
The Chip-DSC 100 (Chip-DSC L66 Ultimate) combines the advantages of chip technology with the requirements of our previous DSC models. Various options such as a sample robot, UV attachment and Raman spectroscopy make the Chip-DSC 100 (Chip-DSC L66 Ultimate) a very versatile measuring device. The chip technology enables high reproducibility and, due to the low mass, excellent temperature control and heating rates of up to 1000 K/min. The integrated sensor is easily replaceable and available at low cost. The integrated design of the chip sensor provides excellent raw data, enabling direct analysis without pre- or post-processing of the heat flow data. Applications on the Chip-DSC 100 (Chip-DSC L66 Ultimate) can be expanded using various accessories. You can use various cooling systems in combination with a sample robot. The sample robot is available with 96 positions.
Differential Scanning Calorimetry
LINSEIS - Model DSC PT1000 - Differential Scanning Calorimeter
This product was developed to provide a general purpose TM - DSC with a broad temperature range(-150 – 725°C)for all common applications. Furthermore emphasis was placed on an extremely stable baseline and high reproducibility. The design allows manual and automatic operation. The conception of the cell guarantees maximum mechanical and chemical resistance.The 120 thermocouple sensor MR12provides highest resolution and outstanding sensitivity.
Thermogravimetry
LINSEIS - Model TGA PT1000 - Thermogravimetry / Thermal Balance Analyzer
The NEW Linseis TGA PT1000 for thermogravimetric applications is a toploading Thermobalance, which offers a highly userfriendly design. Even at a sample weight of up to 5g the tara is done electronically. The specially designed furnaces allow fast heating and cooling rates from 0.01 up to 150°C/min as well as a highly precise temperature control from RT up to 1100°C. The system can be optionally equipped with a coupling device for EGA (Evolved Gas Analysis). The instrument is highly suitable for thermal composition, thermal stability and oxidation studies. The (optional) calculated DTA signal provides important additional information regarding endothermal or exothermal reactions. Furthermore it can be used as a tool for temperature calibration.
Simultaneous Thermal Analysis
LINSEIS - Model STA PT1000 TG-DSC - Thermogravimetric Analyzer
TheLinseis STA PT1000is a top loading Thermobalance, which offers a highly user-friendly design. Even at a sample weight of up to 10g the Tara is done electronically. The specially designed furnaces allow fast heating and cooling rates as well as a highly precise temperature control. The system can be optionally equipped with a coupling device for EGA (Evolved Gas Analysis). The instrument is highly suitable for thermal composition, thermal stability and oxidation studies.
Thermomechanical Analysis
LINSEIS - Model TMA PT1000 - Thermomechanical Analyzer
The design of theLINSEIS TMA PT1000 Thermomechanical Analyzerguarantees highest precision, reproducibility and accuracy. The system was constructed to perform a variety of Thermomechanical experiments on an array of sample shapes and sizes over a wide temperature range to meet all TMA needs. The system can perform eitherstatic or dynamicmeasurements due to a built in force/frequency generator. Typical materials under investigation are: composite materials, glass, polymers, ceramics and metals. The variety of measuring systems allows sample geometries such as fibers, rods, films, rods or cylinders.
Single Differential / Quattro Dilatometer
LINSEIS - Model L76 Platinum Series - Measurement Dilatometer
The main application field for theLINSEIS L76 Dilatometerseries is the CTE measurement of ceramics, brick, tile, porcelain and building materials. Furthermore it is widely used for quality control purposes in ceramics and in metal industries.
Quenching Dilatometer / Laser Dilatometer
LINSEIS - Model L75 PT - Horizontal Dilatometer
The horizontal dilatometer DIL L75 H was developed to meet the demands of the academic community and research laboratories worldwide. With this system, thermal expansion behavior of solids, liquids, powders and pastes for a variety of applications can be precisely determined. The unique design of this system guarantees highest precision, reproducibility and accuracy. This line of instruments is capable of performing measurements under vacuum, oxidizing and reducing atmospheres.
Laser Flash / Xenon Flash Analyzer
LINSEIS - Model XFA 300/600 - Xenon Flash Apparatus Analyzer
Information of the thermo physical properties of materials and heat transfer optimization of final products is becoming more and more vital for industrial applications. Over the past few decades, the flash method has developed into the most commonly used technique for the measurement of the thermal diffusivity and thermal conductivity of various kinds of solids, powders and liquids. TheLinseis XFA 300/600 Xenon Flashoffer a cost effective method to measure the Thermal Diffusivity, Thermal Conductivity and Specific Heat Values for up to 6 Samples at the same time. The modular design of the system enables later upgrade to the sophisticatedLINSEIS LFA 1000system in terms of temperature and Laser Pulse source.
