Quantum Hydrometrie GmbH
10 products found

Quantum Hydrometrie GmbH products

Discharge Measurement - Surface Water - Stationary Systems

Quantum - Flowmeter System for Short Distances

Type: AFC 4-10/200 + 4 sensors. Path lengths: 0,8 to 10 meters. Number of maximal connectable sensors: 4. Frequency: 200 kHZ. Measurement range: -10 to +10 m/s. Accuracy v: < 0,1% deviation. Accuracy Q: < 3% deviation, better than +/- 1%, if calibrated on site. Housing: 330 x 235 x 190 (W x H x D), Compact housing IP 65. Remote control. Remote data transfer: analog, ISDN, GSM, GPRS. Power supply: 12 - 36 VDC. Power consumption: 11 VA at continous operation, < 1 VA at standby mode.

Quantum - Flowmeter Systems for Medium Distances

Path lengths: 10 to 200 meters. Number of maximal connectable sensors: 12. Frequency: 200, 28 kHz. Measurement range: -10 to +10 m/s. Accuracy v: < 0,1% deviation. Accuracy Q: < 3%deviation, better than+/- 1%, if calibrated on site. Housing: 19" housing or. 330 x 235 x 190 (W x H x D), compact housing IP 65. Remote control. Remote data transfer: analog, ISDN, GSM, GPRS. Output: optional USB, Bluetooth. Expandable: W-LAN adapter, added relais control. Power supply: 12 - 36 VDC. Power consumption: 11 VA at continous operation, < 1 VA at standby mode.

Discharge Measurement - Portable Systems

RiverSurveyor - Portable Measurement Systems

Complete 3-D velocity profiling, bathymetric measurement, and discharge calculation as you transect the channel. Combines the highest resolution with the greatest range of depths.

FlowTracker - Handheld Measurement Systems

Designed with the field user in mind, this handheld ADV (Acoustic Doppler Velocimeter) measures 2D or 3D currents, attaches easily to wading rods, and features an automatic discharge computation using a variety of international methods, including ISO and USGS standards. At the end of the data run, just press a button and the FlowTracker calculates the discharge for you!

Discharge Measurement - Sewage Monitoring

Q-Sewage - Flowmeter System for Waste Water

Flowmeter system for waste water; 4 sensors; Path lengths: 0,8 to 10 meters. Number of sensors: 4. Measurement range: -10 bis +10 m/s. Accuracy v: < 0,1% im Messpfad. Accuracy Q: < 1%. Frequency: 200 kHz, explosion proofness. Housing: 330 x 235 x 190 (W x H x D), compact housing IP 65. Remote control. Remote data transmission: optional analog, ISDN, GSM, GPRS. Power supply: 12 - 36 VDC. Power consumption: 11 VA at continous operation, < 1 VA at standby mode.

Q-Sewage - Flowmeter Systems for Waste Water

+ 12 sensors + added relais control: Path lengths: 0,8 to 10 meters. Number of maximal connectable sensors: 12. Measurement range: -10 to +10 m/s. Accuracy v: < 0,1% in measuring circuit. Accuracy Q: < 1%. Frequency: 200 kHz, explosion proofness. Housing: 330 x 235 x 190 (W x H x D), compact housing IP 65. Remote control. Remote data transfer: optional analog, ISDN, GSM, GPRS. Outputs: optional USB, Bluetooth, WLAN. Power supply: 12 - 36 VDC. Power consumption: 11 VA at continous operation, < 1 VA at standby mode.

Discharge Measurement - Pipe Monitoring

Quantum - Flowmeter System for Pipes

+ 4 sensors: Path lengths: 0,8 to 10 meters. Number of sensors: 4. Measurement range: -10 to +10 m/s. Accuracy v: < 0,1% in measuring circuit. Accuracy Q: < 0,5 %. Frequency: 200 kHz. Housing: 330 x 235 x 190 (W x H x D), compact housing IP 65. Power supply: 12 - 36 VDC. Power consumption: 11 VA at continous operation, < 1 VA at standby mode. Remote control.

Quantum - Controller Flowmeter System for Pipes

+ 12 sensors + added relais control: Path lengths: 0,8 to 10 meters. Number of connetable sensors: 12. Measurement range: -10 to +10 m/s. Accuracy v: < 0,1% in measuring circuit. Accuracy Q: < 0,5 %. Frequency: 200 kHz. Housing: 330 x 235 x 190 (W x H x D), compact housing IP 65. Power supply: 12 - 36 VDC. Power consumption: 11 VA at continous operation, < 1 VA at standby mode. Remote control. Remote data transfer: analog, ISDN, GSM, GPRS. optional outputs: USB, Bluetooth, WLAN.

Water Level Measurement - Pressure Sensors

Quantum - Reliable Hydrostatic Pressure Sensor

Long-run robust, ceramic sensor, also applicable for waste water. Robust, modular housing made of stainless steel. 44,5 mm diameter for application in 2" observation well. Output signal 4 - 20 mA. Active compensation of temperature by integrated micro controller. Accuracy: 0,1 %.

Water Level Measurement - Radar Sensor

Quantum - Radar Sensors

The FMR 240 for continuous and contact-free water level measurement in fluids. Variations in temperature and vaporization have no influence on the measurement.