Rexon Components, Inc.
10 products found

Rexon Components, Inc. products

Crystal Scintillators

Rexon - Open Window Crystal Assemblies

If you have any Assemblies that need Repair or Refurbished send them to us and we will make the  repairs at a fraction of the cost of a new unit . If your need is for new Assemblies we do that also , We will make them to the Original OEM specifications or if you have a custom design no problem we do that as well.

Plastic Scintillators

Rexon - Model RP-100 - Plastic Scintillator

Plastic Scintillators offer high performance, ease of handling, mechanical stability at a relatively low cost. The versatility of plastic scintillators makes them the ideal choice for large area and specially shaped detectors.

Rexon - Model RP-200 - Plastic Scintillators

Plastic Scintillators offer high performance, ease of handling , mechanical stability at a relatively Low Cost when compared to Inorganic Scintillators such as NaI(TI). The versatility of plastic scintillators makes them the ideal choice for large area and specially shaped detectors. In particular, The composition formula for RP-200 dates back to the early 1970s  and has been modified to provide the lowest Cost Plastic Scintillator available where timing is a secondary issue concomitant with as good an Efficiency as the RP-408 and RP-400.

Rexon - Model RP-400 - Plastic Scintillators

Plastic Scintillators offer high performance, ease of handling, mechanical stability at a relatively low cost.  The versatility of plastic
scintillators makes them the ideal choice for large area and specially shaped detectors.  RP-400 (having the same formulation as NE 102A) is truly the general purpose scintillator that has been the mainstay over the past fifty years for use in industrial and health physics measurement alpha, beta, gamma and neutron radiation as well as numerous medical instruments and scientific research ranging from low background shields in nuclear physics to space-borne astrophysics systems. It is available in geometries ranging from very thin films to thick cast sheet, rods and ingots.

Rexon - Model RP-408 - Plastic Scintillators

Plastic Scintillators offer high performance, ease of handling, mechanical stability at a relatively low cost.  The versatility of plastic scintillators makes them the ideal choice for large area and specially shaped detectors.

TLD Systems - UL-320 Series TLD Readers

Rexon - Model UL-320 Series - TLD Readers

DIRECT CONTACT PLANCHET Heating Processes ALL TLD Dosimeters And Even Powder. Superior Design-Lower Cost-User Friendly
BarCodeScanner , Auto N2 shut-off & 10 Nodes for Temperature Profiling. Displays Digitized Glow-Curve And Temperature File. Unlimited Configuration And Calibration For Any Unit of Measurement. Simple And Accurate Analysis. Bar Coded Planchet For Track Of Dosimeters. Verification For A Built-In Quality Control Check. Reference Light Source For Real-Time PMT Drift Correction & HV  adjust in 1-volt increments. Dosimeter Correction Factor Storage And Automatic Call-Up. Automatically Processes Up To 185 Dosimeters - More with Extended mags. optional. Option For Weight Input From Electronic Balance for Powder Samples. PC Programmable Powder Vibrator. Internal µProcessor-RS 232 Connection to any device. Windows XP compatible Software.

Rexon - Model UL-320 AD - TLD Readers

DIRECT CONTACT PLANCHET HEATING For Best Heat Transfer And Accuracy. Processes ALL TLD Dosimeters — POWDER, CHIPS, RIBBONS, PELLETS, DISK, RODS & MICRO CUBES. Superior Design-Lower Cost-User Friendly. Displays Digitized Glow-Curve And Temperature  File-10 NODES available. Unlimited Configuration And Calibration For Any Unit of Measurement. Simple And Accurate Analysis. Auto N2 shut-off & Automated Drawer. Bar Coded Planchet For Track Of Dosimeters. Dosimeter Correction Factor Storage And Automatic Call-Up. Verification For A Built-In Quality Control Check. Reference Light Source For Real-Time PMT Drift Correction & HV  adjust in 1-volt increments. Internal µProcessor-RS 232 Connection to device. Windows XP   compatible Software. Option For Weight Input From Electronic Balance for Powder Sample Correlation. Option BarCodeScanner.

Rexon - Model UL-320 M - TLD Readers

DIRECT CONTACT PLANCHET HEATING For Best Heat Transfer And Accuracy. Processes ALL TLD Dosimeters — POWDER, CHIPS, RIBBONS, PELLETS, DISK, RODS & MICRO CUBES. Superior Design-Lower Cost-User Friendly. Displays Digitized Glow-Curve And Temperature  File-10 NODES available. Unlimited Configuration And Calibration For Any Unit of Measurement. Simple And Accurate Analysis. Auto N2 shut-off. Bar Coded Planchet For Track Of Dosimeters. Dosimeter Correction Factor Storage And Automatic Call-Up. Verification For A Built-In Quality Control Check. Reference Light Source For Real-Time PMT Drift Correction & HV  adjust in 1-volt increments. Option For Weight Input From . Electronic Balance for Powder Sample Correlation. Internal µProcessor-RS 232 Connection to device. Windows XP compatible Software.

TLD Systems

Rexon - Model 330 TLD - Reader

Our Custom Orientation Philosophy results in low cost-of-ownership (COO). Highest Volume Reader: The highest volume reader in the industry at 1700 cards. Most Dosimeters/Card: The card can have EIGHT dosimeters!

TLD Accessories

Rexon - Model 320-MAGZ - Load Magazine

For Planchets - At least 2 Spares Recommended. Standard Magazines Capacity = 185 with weights using Disc Planchets. Larger Capacity Magazines are available.