Tosoh Bioscience LLC products
EcoSEC GPC System
EcoSEC - GPC System with RI and UV Detectors
The EcoSEC GPC System with RI and UV Detectors is an all-in-one GPC system with RI and UV detectors, operating in temperatures ranging from ambient to 60 °C. This instrument delivers superior performance and unmatched baseline stability resulting from the unique dual flow RI detector design. The degree of precision in retention time and molar mass determination far exceeds the market standard due to its advanced temperature controlled pumps and the overall thermal stability of the entire system. This high level of engineering results in baselines that stabilize within 90 minutes, exhibit less noise and drift, and deliver exceptional reproducibility day to day, system to system, and site to site.
EcoSEC - GPC System with RI Detector
The EcoSEC GPC System with RI Detector is an all-in-one GPC system with an RI detector, operating in temperatures ranging from ambient to 60 °C. This instrument delivers superior performance and unmatched baseline stability resulting from the unique dual flow RI detector design. The degree of precision in retention time and molar mass determination far exceeds the market standard due to its advanced temperature controlled pumps and the overall thermal stability of the entire system. This high level of engineering results in baselines that stabilize within 90 minutes, exhibit less noise and drift, and deliver exceptional reproducibility day to day, system to system, and site to site.
EcoSEC - High Temperature GPC System with RI Detector
The EcoSEC High Temperature GPC System with RI Detector is an all-in-one GPC system, operating in temperatures ranging from ambient to 220 °C. This instrument delivers unparalleled baseline stability, reproducibility, and reliability due to the high level of precision in thermal stability throughout the system, the unique dual flow RI detector design, and low dead volume.
HPLC Columns
TSKgel - Model QC-PAK GFC 200 - Column
The TSKgel QC-PAK GFC 200 column is 15 cm in length with 5 μm particles. This stainless steel column offers the same resolution in half the time as the 30 cm, 5 μm TSKgel G2000SWxl column.
TSKgel Alpha - Model 2500 - Column
The TSKgel Alpha-2500 column is packed with rigid, porous, polymer beads which show minimal shrinkage or swelling in polar organic solvents (methanol, acetonitrile, DMSO, isopropanol, THF, and HFIP). This column is stable in a wide variety of organic solvents at concentrations up to 100%.
TSKgel Alpha - Model 3000 - Column
The TSKgel Alpha-3000 column is packed with rigid, porous, polymer beads which show minimal shrinkage or swelling in polar organic solvents (methanol, acetonitrile, DMSO, isopropanol, THF, and HFIP). This column is stable in a wide variety of organic solvents at concentrations up to 100%. The main application area for the TSKgel Alpha-3000 column is the analyses of polymers that are soluble in polar organic solvents up to 100,000 Da. Examples include cellulose derivatives, polyimide, and sodium dodecylsulfate (all in 10 mmol/L LiBr in DMF), cleansing gel in methanol, and degree of saponification of polyvinylalcohol in hexafluoroisopropanol (HFIP).
TSKgel Alpha - Model 4000 - Column
The TSKgel Alpha-4000 column is packed with rigid, porous, polymer beads which show minimal shrinkage or swelling in polar organic solvents (methanol, acetonitrile, DMSO, isopropanol, THF, and HFIP). This column is stable in a wide variety of organic solvents at concentrations up to 100%. The main application area for the TSKgel Alpha-4000 column is the analyses of polymers that are soluble in polar organic solvents up to 1 x 106 Da. Examples include cellulose derivatives, polyimide, and sodium dodecylsulfate (all in 10 mmol/L LiBr in DMF), cleansing gel in methanol, and degree of saponification of polyvinylalcohol in hexafluoroisopropanol (HFIP).
TSKgel Alpha - Model 5000 - Column
The TSKgel Alpha-5000 column is packed with rigid, porous, polymer beads which show minimal shrinkage or swelling in polar organic solvents (methanol, acetonitrile, DMSO, isopropanol, THF, and HFIP). This column is stable in a wide variety of organic solvents at concentrations up to 100%. The main application area for the TSKgel Alpha-5000 column is the analysis of polymers that are soluble in polar organic solvents up to 7 x 106 Da. Examples include cellulose derivatives, polyimide, and sodium dodecylsulfate (all in 10 mmol/L LiBr in DMF), cleansing gel in methanol, and degree of saponification of polyvinylalcohol in hexafluoroisopropanol (HFIP).
TSKgel Alpha - Model 6000 - Column
The TSKgel Alpha-6000 column is packed with rigid, porous, polymer beads which show minimal shrinkage or swelling in polar organic solvents (methanol, acetonitrile, DMSO, isopropanol, THF, and HFIP). This column is stable in a wide variety of organic solvents at concentrations up to 100%. The main application area for the TSKgel Alpha-6000 column is the analyses of polymers that are soluble in polar organic solvents greater than 10 x 106 Da. Examples include cellulose derivatives, polyimide, and sodium dodecylsulfate (all in 10 mmol/L LiBr in DMF), cleansing gel in methanol, and degree of saponification of polyvinylalcohol in hexafluoroisopropanol (HFIP).
Process Development Products
Tosoh - Model 96 - Column Packing with TOYOPEARL Process Media
The Resin Seeker Ca⁺⁺Pure-HA 96-well plate kit is packed with 20 µL or 500 µL of Ca⁺⁺Pure-HA resin per well. All components necessary to run an experiment are included in each kit: a wash plate and collection plate are included in each 96-well plate package. These 96-well plate kits are manufactured by Orochem and sold by Tosoh Bioscience.
