- Home
- Companies
- UVRER ANEMO
- Products
- Water Disinfection - Industries & Collectivities - UV-C Sterilizers Range Without Filtration - Eureka Industrial
- Water Disinfection - Industries & Collectivities - UV-C Sterilizers Range Without Filtration - DFI Range
- Water Disinfection - Industries & Collectivities - UV-C Sterilizers Range Without Filtration - FZI Range
- Water Disinfection - Industries & Collectivities - UV-C Sterilizers Range Without Filtration - FTA Range
- Water Disinfection - Industries & Collectivities - UV-C Sterilizers Range Without Filtration - HDPE Range
- Water Disinfection - Industries & Collectivities - UV-C Sterilizers Range Without Filtration - HM Range
- Water Disinfection - Industries & Collectivities - UV-C Sterilizers Range With Filtration - FZI Station
- Water Disinfection - Pools SPAS & Natural Ponds - Disinfection of Bathing Water - SUNEO
UVRER ANEMO products
Water Disinfection - Industries & Collectivities - UV-C Sterilizers Range Without Filtration - Eureka Industrial
Eureka - Industrial UV-C Sterilizers Range Without Filtration
Eureka 18 Industrial: Max flow : 0,6-1 m3/h, Power : 1X18W, In/Out : 3/4’’. 316L stainless steel chamber. Max pressure 6 bars (higher pressure on demand). Water temperature 0 to 40°C. Connection in opposite axis. Domed quartz sleeve. Sampling valves. Synthetic fixation ring. Industrial electrical box. Single-ended lamp M12 resine-coated jar. Lamp visual witness. Electronic ballast / Default contact plate. Electromecanical hour counter. 220 V+T supply.
Eureka - Industrial UV-C Sterilizers Range Without Filtration
Eureka 36 Industrial: Max flow: 1,4-2,2 m3/h, Power: 1X36W, In/Out: 3/4’’. 316L stainless steel chamber. Max pressure 6 bars (higher pressure on demand). Water temperature 0 to 40°C. Connection in opposite axis. Domed quartz sleeve. Sampling valves. Synthetic fixation ring. Industrial electrical box. Single-ended lamp M12 resine-coated jar. Lamp visual witness. Electronic ballast / Default contact plate. Electromecanical hour counter. 220 V+T supply.
Eureka - Industrial UV-C Sterilizers Range Without Filtration
Eureka 55 Industrial: Max flow: 1,9-3 m3/h, Power: 1X55W, In/Out: 3/4’’. 316L stainless steel chamber. Max pressure 6 bars (higher pressure on demand). Water temperature 0 to 40°C. Connection in opposite axis. Domed quartz sleeve. Sampling valves. Synthetic fixation ring. Industrial electrical box. Single-ended lamp M12 resine-coated jar. Lamp visual witness. Electronic ballast / Default contact plate. Electromecanical hour counter. 220 V+T supply.
Eureka - Industrial UV-C Sterilizers Range Without Filtration
Eureka 95 Industrial: Max flow: 3,1-4,9 m3/h, Power: 1X95W, In/Out: 1’’. 316L stainless steel chamber. Max pressure 6 bars (higher pressure on demand). Water temperature 0 to 40°C. Connection in opposite axis. Domed quartz sleeve. Sampling valves. Synthetic fixation ring. Industrial electrical box. Single-ended lamp M12 resine-coated jar. Lamp visual witness. Electronic ballast / Default contact plate. Electromecanical hour counter. 220 V+T supply.
UVRER - UV-C Sterilizers Range without Filtration
FZI 100 - Max flow: 10 – 16 m3/h, Power: 115W box, In/Out: 2’’ MA. 316L stainless steel chamber. Max pressure 6 bars (higher pressure on demand). Water temperature 0 to 40°C. Visual control cell. Theaded connection. Quartz sleeve. Sampling valve. Inspection door and drain valve for FZI 100. Electromecanical hour counter. IP55 waterproof electrical enclosure. Double-ended lamp 9 000 h. Lamp visual witness. Electronic ballast. 220 V+T supply to be provided.
Water Disinfection - Industries & Collectivities - UV-C Sterilizers Range Without Filtration - DFI Range
UVRER - UV-C Sterilizers Range Without Filtration
DFI 130 - Max flow: 15,08 m3/h. Power: 1X130W cabinet. In/Out: 2’’MA flanges. 316 L stainless steel chamber. Max. pressure 6 bars (higher pressure on demand). Water temperature 0 to 40 °C. Visual control cell. Flanged connections. Quartz sleeve. Sampling valve
Inspection door and drain valve. Electromecanical hour counter. Electrical cabinet. Single-head lamp amalgam 12 000h. Lamp visual witness. Electronic ballast. 220 V+T supply to be provided.
UVRER - UV-C Sterilizers Range Without Filtration
DFI 230 - Max flow: 25,55 m3/h, Power: 2X130W cabinet, In/Out: 2’’1/2 MA flanges. 316 L stainless steel chamber. Max. pressure 6 bars (higher pressure on demand). Water temperature 0 to 40 °C. Visual control cell. Flanged connections. Quartz sleeve. Sampling valve
Inspection door and drain valve. Electromecanical hour counter. Electrical cabinet. Single-head lamp amalgam 12 000h. Lamp visual witness. Electronic ballast. 220 V+T supply to be provided.
UVRER - UV-C Sterilizers Range Without Filtration
DFI 330 - Max flow: 52,55 m3/h, Power: 3X130W cabinet, In/Out: 3’’ MA flanges. 316 L stainless steel chamber. Max. pressure 6 bars (higher pressure on demand). Water temperature 0 to 40 °C. Visual control cell. Flanged connections. Quartz sleeve. Sampling valve
Inspection door and drain valve. Electromecanical hour counter. Electrical cabinet. Single-head lamp amalgam 12 000h. Lamp visual witness. Electronic ballast. 220 V+T supply to be provided.
UVRER - UV-C Sterilizers Range Without Filtration
DFI 430 - Max flow: 77,53 m3/h, Power: 4X130W cabinet, In/Out: 4’’ MA flanges. 316 L stainless steel chamber. Max. pressure 6 bars (higher pressure on demand). Water temperature 0 to 40 °C. Visual control cell. Flanged connections. Quartz sleeve. Sampling valve
Inspection door and drain valve. Electromecanical hour counter. Electrical cabinet. Single-head lamp amalgam 12 000h. Lamp visual witness. Electronic ballast. 220 V+T supply to be provided.
UVRER - UV-C Sterilizers Range Without Filtration
DFI 530 - Max flow: 110,48 m3/h, Power: 5X130W cabinet, In/Out: 4’’ MA flanges. 316 L stainless steel chamber. Max. pressure 6 bars (higher pressure on demand). Water temperature 0 to 40 °C. Visual control cell. Flanged connections. Quartz sleeve. Sampling valve
Inspection door and drain valve. Electromecanical hour counter. Electrical cabinet. Single-head lamp amalgam 12 000h. Lamp visual witness. Electronic ballast. 220 V+T supply to be provided.
