Automatic Control Valves

Watts - Automatic Control Valves

Series 1116FM (Angle) Relief Valve meets all requirements for UL listed, FM Approved fire protection service. The design and features incorporated in the WATTS ACV valves assure accurate control, dependable performance, and long life. Automatically maintains a constant pressure in the fire protection system by relieving excess pressure. Angle Pattern Single Chamber Relief Valve.

Watts - Automatic Control Valves

Series 116FM (Globe) Relief Valve meets all requirements for UL listed, FM Approved fire protection service. The design and features incorporated in the WATTS ACV Valves assure accurate control, dependable performance, and long life. Automatically maintains a constant pressure in the fire protection system by relieving excess pressure. Globe Pattern Single Chamber Relief Valve.

Backflow Preventers

Watts - Double Check Valve

Series 007 double check valve assembly backflow preventers include a freeze sensor for use with SentryPlus Alert® technology to signal facility personnel when temperature nears and reaches the freezing point. Freeze alerts feature available with add-on connection kit for Wi-Fi networks, building management systems (BMS), and irrigation management systems (IMS). This series is designed to prevent the backflow of contaminated water from entering the potable water supply. Bronze valve body (1/2 to 2 IN). Easy to maintain and service. Ideal at referenced cross-connections identified as non-health hazard applications. Check with local inspection authorities for installation requirements. Maximum Working Pressure: 175 psi (12.06 bar).

 

Hydronic & Steam Heating - Air Separators

Watts - Air Separators

Series AS Air Separators are used in commercial and residential, hydronic heating applications to separate air from water in the piping system. They consist of a heavy, cast-iron body construction with a 1/2 in. female threaded connection for an expansion tank, and a 1/8 in. female threaded connection for a float vent. Series AS provides continuous purging and venting of air in the system when installed with Watts Model ET expansion tank and Model FV4 float-vent. Maximum Pressure: 125psi (8.6 bar).

Hydronic & Steam Heating - Balancing Valves

Watts - Flow Measurement Valves

Series CSM-61-T flow measurement valves are designed for application on low or medium flow rate HVAC units recirculation system. Their compact size allows for easy installation and use in crowded piping compartments. The CSM-61-T's ball-type design, extended throttling range, and large indicator plate, make for accurate flow measurement, even in very low flow ranges. The LFCSM-61-T's positive memory feature is easy to see, access, and operate, facilitating system balancing and flow measurement. These valves are also bi-directional, so there is no chance of installing the valve in the incorrect flow direction.

Mixing Valves - Lavatory Mixing Valves

Watts - Thermostatic Mixing Valves

Series LFMMV Thermostatic Mixing Valves maintain and limit mixed hot water to a desired, selectable temperature. The LFMMV series can be set to any temperature between 80 degrees F and 120 degrees F with flow rates as low as 0.5 gpm and as high as 12 gpm (refer to capacity chart). This mixing valve series is listed under ASSE 1017 for valves used in hot water source applications, ASSE 1069 for single-pipe, tempered water applications, and ASSE 1070 for valves used in individual or multiple fixture applications, and also listed IAPMO cUPC. The LFMMVs feature Lead Free* construction to comply with Lead Free* installation requirements.

Pressure Reducing Valves - Pressure Reducing Valve Kits

Watts - Jumper Kits

Jumper Kits are used in new construction as a temporary by-pass, prior to the actual installation of a water pressure reducing valve on potable water supply systems. The use of a temporary jumper permits testing of the building piping system for leaks and pressure loss and facilitates pipe flushing prior to the installation of the water pressure reducing valve. On unsecured jobsites, the jumper kit reduces loss from theft or vandalism. Kits consist of union connections, washers, SS strainer, and brass or plastic pipe nipple.

Relief Valves - ASME Safety Valves

WATTS - ASME Safety Boiler Pressure Relief Valves

Series 335 ASME rated Boiler Pressure Relief Valves were developed to fill the hydronic industry's need for a smaller valve for OEM use on popular size boilers up to 510,000 BTU at 30psi (2.11 bar). The compact design, all bronze construction, and modern appearance make them an ideal choice for a wide variety of smaller size OEM boilers. ASME Section IV at 30 psi set point.

Shutoff Valves - Ball Valves

WATTS - Single Lever Bronze Washing Machine Water Shutoffs Valve

Series 175C single lever bronze washing machine water shutoff valve controls both hot and cold water simultaneously. It consists of bronze body, 5/8 in. OD solder for 1/2 in. copper tube, single handle, 1/2 inch sweat copper ell adapters for copper tubing and 3/4 inch hose outlet connection.