Zhejiang FULI Analytical Instrument Co., Ltd products
Gas Chromatograph
Fuli - Model GC 9720 Plus - Gas Chromatograph System
System capability: Assembly simultaneously: 2 inlets+3 detectors(FID, TCD, ECD, FPD optional). Independent split cold-trap and septum collecting trap, Carrier gas control mode: pressure, flow, programming pressure, programming flow, Programming pressure/flow/linear speed: max 8 steps, Maintenance tracking reminder, intelligent regular maintenance plan.
Fuli - Model GC 9790 Plus - Gas Chromatograph System
System capability: Assembly simultaneously: max 2 inlets+ max 3 detectors(FID, TCD, ECD, FPD and NPD). Automatic control can be done from local keyboard and networked PC. Autosampler is compatible. 6-channel independent temperature control.
Fuli - Model GC 9790 II - Gas Chromatograph System
System capability: Assembly simultaneously: 3 inlets+3 detectors(FID, TCD, ECD, FPD and NPD). Large 320*240 LCD screen. Carrier gas control: pressure/flow regulator. 6 channels independ temperature control. Controllable by PC.
GC Accessories
Fuli - Model FLDK 5001B - Headspace Autosampler
Vial qty: 12, Heating vial qty: 4, Vial volume: 20ml, Loop volume: 1ml(0.5ml and 3ml optional), Vial heating temp range: 40?~200?, 1? increment selectable, Valve loop heating temp range: 40?~220?, 1? increment selectable, Sample transfer line heating range: 40?~220? , 1? increment selectable, Injecting peak area RSD≤1.5% (sample is 0.02% ethanol water solution, N=10), Colorful text displayer, Double-channel simultaneous-starting output communication port.
FULI - Model FLDK 5001A - Headspace Autosampler
Vial qty: 36, Heating vial qty: 9, Vial volume: 20ml, Loop volume: 1ml(0.5ml and 3ml optional), Vial heating temp range: 40?~200?, 1? increment selectable, Valve loop heating temp range: 40?~220?, 1? increment selectable, Sample transfer line heating range: 40?~220? , 1? increment selectable, Injecting peak area RSD≤1.5% (sample is 0.02% ethanol water solution, N=10), Colorful text displayer, Double-channel simultaneous-starting output communication port
Fuli - Model FL1092T - Autosampler
Area RSD ≤1.0%. Residue ≤1/100000. Injection feature: Fast injection in default, fast/slow mode selectable. Fast injection mode: injection period <100ms. Support sandwich injection mode. Solvent saving mode available.
HPLC
Fuli - Model LC5090 - High Performance Liquid Chromatograph Pump System
Isocratic/High pressure binary gradient/Low pressure quaternary gradient. Double-plunger tandem reciprocating pump. Flow range: 0-10ml/min. Flow RSD: 0.06%. Flow accuracy: ≤±1%. Pressure range: 42Mpa. Automatic plunger washing. Automatic leaking alarm. CAN communication. Voltage/frequency: AC 100V~240V/50-60Hz. GLP: running/maintenance history available.
Fuli - Model LC5090 - Column Oven
Heating method: semiconductor heating/cooling. Temperature: lower than ambient temp. 5 to 80?. Temperature accuracy/stability:±0.5?/0.05?. Temperature ramp speed: in 15min from 20 to 50?. Temperature cool-down speed: in 15min from ambient temp to ambient temp-5?. LC column capacity: 2. CAN communication. Over-heating alarm: recoverable thermal protector. Automatic leaking alarm. Power: 200W. GLP: running/maintenance history available. Voltage/frequency: AC 100V~240V/50-60Hz.
Fuli - Model LC5090 - UV Detector
Double-beam UV detector. Detection wavelength: 190nm-700nm. Optical path: 10mm. Bandwidth: 8nm. Flow cell volume: 10ul.
Fuli - Model LC5090 - Autosampler
Injection volume variable. Injection way: partial or full-loop. Injection volume : 1-100ul(standard)/0.1-2000ul(optional). Sample volume: 180 vial(2ml).
