California Analytical Instruments, Inc. (CAI)

1314/1412 Photoacoustic Analyzer Specification Sheets (PDF 239 KB)

PHOTOACOUSTIC 1314/1412 1314/1412 1314/1412 INNOVA INNOVA INNOVA APPLICATIONS • Process Quality Control • Stack Gases • VOC/THC Analysis • Fermentation/Greenhouse Gases • Vehicle Emissions • Trace Gas Analysis • Occupational Health and Safety • Monitoring of Livestock Emissions OPTIONS • Analog Interface Module for 0-10 Volt or 4-20 mA • Battery Pack for Battery Operation • Microprobe for Liquid/Headspace Sampling • Additional Carousel for up to Five Additional Gases • Multipoint Sampler 1312 West Grove Avenue Orange, CA 92865-4134 Phone: 714-974-5560 Fax: 714-921-2531 www.gasanalyzers.com MULT-GAS ANALYZER FEATURES • Measures up to Five Gases Plus H2O • Measurement Capability for Large Number of Gases • Sensitivity from PPB to % Levels • Extreme Stability Minimizes Calibration Frequency • Highly Accurate and Free From Interfering Gases • Temperature and Pressure Compensation • Rack Mounted Version (1314) • Standard IEEE-488 and RS-232 Interfaces • Minimal Maintenance Required— Only Replacement of the Air Filter • User-Friendly Operation/1 Hour Warm Up • Self-Testing Internal Diagnostics Assure High Reliability 1314/1412 PHOTOACOUSTIC ANALYZER INNOVAINNOVAINNOVA SPECIFICATIONS DETECTION LIMIT: Gas Dependent but typically in the ppb Region. Consult factory for specific data. DYNAMIC RANGE: Typically 4 orders of magnitude ZERO DRIFT: Typically +/- detection limit per 3 months SPAN DRIFT: Typically +/- 2.5% of measured value per 3 months REPEATABILITY: 1% of measured value INFLUENCE OF TEMPERATURE: +/- 0.3% of measured value INFLUENCE OF PRESSURE: 0.01% of measured value POWER CONSUMPTION: Approximately 120 VA DIMENSIONS AND WEIGHT: 1314 1412 H: 6.9”, W: 19”, D: 14.8” H: 6.9”, W: 15.6, D: 11.8” Weight: 30.8 pounds Weight: 19.8 pounds Specifications subject to change without notice. DESCRIPTION The Innova Photoacoustic gas analyzers are highly accurate, reliable, and stable. Two versions of the analyzer are offered, the Model 1412 which is configured for bench top operation and the Model 1314 which is configured for rack mounted operation. The measurement system is based on photoacoustic Infrared detection and provides the capability of measuring virtually any gas that absorbs in the infrared spectrum. Gas selectivity is achieved through the use of optical filters which provide both a means of detecting the gas of interest and compensating for interfering gases and water. METHOD OF OPERATION 1312 West Grove Avenue Orange, CA 92865-4134 Phone: 714-974-5560 Fax: 714-921-2531 www.gasanalyzers.com APPLICATIONS ADP234.tmp DESCRIPTION The Innova Photoacoustic gas analyzers are highly accurate, reliable, and stable. Two versions of the analyzer are offered, the Model 1412 which is configured for bench top operation and the Model 1314 which is configured for rack mounted operation. The measurement system is based on photoacoustic Infrared detection and provides the capability of measuring virtually any gas that absorbs in the infrared spectrum. Gas selectivity is achieved through the use of optical filters which provide both a means of detecting the gas of interest and compensating for interfering gases and water. METHOD OF OPERATION
Most popular related searches