Process Analysers Systems Ltd

3000PA - Panel Mount Percent Oxygen Analyser Brochure

Process PercentOxygen AnalyzerMODEL 3000PAProcess PercentOxygen AnalyzerTELEDYNEANALYTICAL INSTRUMENTSBuilt for Reliability and PerformanceTeledyne’s Model 3000PA brings percent oxygen analysis to new heights of precision. Using advanced microprocessor technology, this model makes the task of percent oxygen analysis easier, faster and more accurate than ever before. Simple menu choices, membrane command switches and a large LED display make setup and operation of a 3000PA clear and quick.Analysis RangesThree user-configurable ranges are standard, with excellent linearity of analysis precluding recalibration when changing ranges. Two fully programmable concentration alarms provide the versatility to satisfy nearly any requirement. All features offer next-generation engineering to assure the 3000PA provides years of operational service.Outputs For DataStandard 0-1 VDC outputs are provided for oxygen measurements and range identification. For two-way communication, an RS-232C serial interface is incorporated to converse with a host computer for remote monitoring and control of all functions. Configuration modifications and analysis results are as close as your computer.Ambient Air CalibrationThe high-accuracy and fast response of Model 3000PA is only surpassed by its ability to calibrate without the assistance of support gases. The Micro-fuel Cell produces an output that is linear from 0 ppm to 100% O2, enabling the use of ambient air for calibration. Custom EngineeringThe 3000PA can be ordered as a standard unit or as part of a larger analytical system. Teledyne can also supply special sensors, custom engineered analyzers, and complete monitoring systems to satisfy unique applications.Advantages• Linearity of analysis across 3 user-selectable ranges• Remote access to all functions from computer• Ambient air calibration• AutoRanging to follow process upsetsApplications• Air separation and liquefaction• Pure, gaseous hydrocarbon stream monitoring• Emissions monitoring• Protective atmosphere blanketing of primary liquid feedstocks and flammable liquids• Process monitoring of gaseous monomers - vinyl chloride, propylene, butadiene, isoprene, or ethylene• Gas purity certificationMODEL 3000PA PERCENT OXYGEN ANALYZERStandard Features• Three user-selectable ranges plus cal range (0-25%)• Signal output: 0-1 VDC• Programmable Auto Ranging• Range ID output: 0-1 VDC• Range ID contacts (Quantity 4). Form A normally open contacts, 3A resistive• Two fully-adjustable concentration alarm points with programmable relay function. Form C contacts, 3A resistive• Programmable auto cal/zero. Form A normally open contact relay signals• Remotely initiated cal/zero via customer supplied 24 VDC signal• Self diagnostics with Form C failure alarm contacts• Full duplex RS232 communication link • Five digit oxygen concentration LED display• Backlit 2 x 20 line alphanumeric VFD for setup and diagnostics• Sampling system: nylon with brass fittings• Sample flow indicator• Universal power supply: 85-250 VAC 47-63 HzOptions-C Auto cal/zero with integrally mounted control valves-M Isolated 4-20 mADC signal output Isolated 4-20 mADC range ID output-S 316 stainless steel sampling system-K 19" Rack Mount with either one or two control unitsSpecificationsRanges: 3 user definable ranges from 0-1% to 0-100%Calibration range: 0-25%Sensor: Class B-1Alarms: One system failure alarm contact to detect power failure. Two adjustable concentration threshold alarms with fully programmable set pointsAccuracy: ± 2% of FS at a constant temperature ± 5% of FS over operating temperature range (once temperature equilibrium has been reached)Response: (90% of FS) at 77°F (25°C) 10 secondsOperating temp: 32°F to 122°F (0°C to 50°C)Signal output: Analytical measurement - 0-1 VDCRange ID output: 0-1 VDCAnalysis display: 5 digit red LED, 3/5" high numeralsMenu display: 20 character, 2 line alphanumeric VFD screenData lines: Bi-directional RS-232C serial interfacePower requirements: Universal AC input ranges - 85 to 250 VAC, 47-63 HzSample connections: User specified 1/4" or 6mm fittingsArea classifications: General purposeMounting: Flush panel mountDimensions: 8.70" W x 6.96" H x 12.2” D 10.79" W x 7.46" H (panel)© 2006 Teledyne Analytical Instruments, A Teledyne Technologies Company.All rights reserved. Printed in the USA. 09/06LDWarrantyInstrument is warranted for 1 year against defects in material or workmanshipNOTE: Specifications and features will vary with application. The above are established and validated during design, but are not to be construed as test criteria for every prod-uct. All specifications and features are subject to change without notice.TELEDYNE ANALYTICAL INSTRUMENTSA Teledyne Technologies Company16830 Chestnut StreetCity of Industry, California 91748, USATEL: 626-934-1500 or 888-789-8168FAX: 626-934-1651 EMAIL: ask_tai@teledyne.comwww.teledyne-ai.com
Most popular related searches