WTEC Energy Innovation
- Home
- Companies & Suppliers
- WTEC Energy Innovation
- Downloads
- 35KV Concentric Neutral Cable, 345 Mils ...
35KV Concentric Neutral Cable, 345 Mils TRXLPE (100% Insulation Level) for Collection Systems brochure
PRODUCT DATA SHEET 34.5 KV CONCENTRIC NEUTRAL CABLE, 345 MILS TRXLPE (100% INSULATION LEVEL) FOR COLLECTION SYSTEMS 03/14/2012 DR One Bridge Plaza North Suite 260 I Fort Lee, NJ 07024 I Tel 201 242 9906 I Fax 201 242 9926 Revision Description WTEC part number Date Submitted By E 2/0-19 added with 10x14 N Axxx-01UD35GTRxxJ 07/13/2011 SS F 4/0-19 added with 16#14, 1/2N Axxx-01UD35GTRxxJ 01/04/2012 SS G 1000 MCM added with 1/12 N Axxx-01UD35GTRxxJ 01/27/2012 SS H Updated Ampacity Values Axxx-01UD35GTRxxJ 03/14/2012 CF 1. SCOPE This annotation describes Tree-Retardant Cross-Linked Polyethylene (TR-XLPE) insulated Linear Low Density Polyethylene (LLDPE) jacketed concentric wire neutral power cables to be used in underground collection systems. The cables are designed for use in three phase systems with voltage not exceeding 35000 volts phase to phase and conductor temperatures not exceeding 90°C for normal operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. The cables are suitable for direct burial and installation in ducts. 2. APPLICABLE STANDARDS: The cables produced under this specification will comply with all applicable requirements of the following standards, which are the principal standards of this product: ICEA S-94-649-2004 (Standard for Concentric Neutral Cables Rated 5 through 46 KV) AEIC CS8-00 (Specification for Extruded Dielectric, Shielded Power Cables Rated 5 through 46 KV) Cable components, raw materials, and testing procedures shall meet the requirements of publications referenced in relevant parts of the principal standards, including but not limited to ASTM B 231, ASTM B 3, ASTM B 5, and ICEA T-31-610. NOTE: WTEC Medium-Voltage cables for collection systems can be made to CAN-CSA-C68.3-97 standard by request. 3. CONSTRUCTION: The cables are designed and manufactured according to a “DISCHARGE-FREE” design concept. Conductor shield, insulation, and insulation shield are extruded simultaneously over the conductor by using triple-extrusion and dry-curing technology. Cable components are: A) CONDUCTOR Conductor shall be class B stranded compressed aluminum. The stranded conductor shall be water-blocked. The wires before stranding shall meet requirements of ASTM B 230. Typical conductor sizes are 1/0 AWG, 4/0 AWG, 350 KCMIL, 500 KCMIL, 750 KCMIL, 1000 KCMIL, and 1250 KCMIL, other sizes are available upon request. B) CONDUCTOR SHIELD The semi-conducting shield shall be extruded over the stranded conductor. C) INSULATION A layer of tree-retardant cross-linked polyethylene (TR-XLPE) shall be extruded over the conductor shield. Nominal thickness of the insulation shall be 345 mils. Minimum thickness shall not be less than 330 mils and maximum thickness not more than 375 mils. D) INSULATION SHIELD The semi-conducting shielding thermosetting compound shall be extruded over the insulation. E) CONCENTRIC NEUTRAL Bare annealed copper wires shall be helically applied over the extruded insulation shield in one layer. They shall be evenly spaced around the cable core. Number and size of the neutral wires shall be specified by the customer; otherwise the ones most commonly used in underground collection systems of the wind farms will be assumed (these values are referenced in Section 5 of this annotation). The wires shall meet the chemical requirements of ASTM B 5 and resistivity, tensile, and elongation requirements of ASTM B 3. F) NON-CONDUCTING JACKET Black linear low density polyethylene shall be extruded (Extruded-to-Fill) over the outer surface of the cable. 3 red stripes spaced 120° apart around the cable center shall be extruded longitudinally on the jacket surface. PRODUCT DATA SHEET 34.5 KV CONCENTRIC NEUTRAL CABLE, 345 MILS TRXLPE (100% INSULATION LEVEL) FOR COLLECTION SYSTEMS 03/14/2012 DR One Bridge Plaza North Suite 260 I Fort Lee, NJ 07024 I Tel 201 242 9906 I Fax 201 242 9926 Revision Description WTEC part number Date Submitted By E 2/0-19 added with 10x14 N Axxx-01UD35GTRxxJ 07/13/2011 SS F 4/0-19 added with 16#14, 1/2N Axxx-01UD35GTRxxJ 01/04/2012 SS G 1000 MCM added with 1/12 N Axxx-01UD35GTRxxJ 01/27/2012 SS H Updated Ampacity Values Axxx-01UD35GTRxxJ 03/14/2012 CF 4. TESTING Cables shall be tested as described in Part 9 of ICEA S-94-649-2004 and part G of AEIC CS8-00. Corresponding production tests shall be done in accordance with ICEA T-27-581, ICEA T-28-562, ICEA T-24-380, and ICEA T-31-610. Factory test reports are available upon request. TEMPERATURE RATINGS: Conductor maximum continuous temperature = 90^C Emergency temperature = 130 OC Storing & working temperature range = -40 …+90^C Installation & handling temperature = - 10…+40^C PRODUCT DATA SHEET 34.5 KV CONCENTRIC NEUTRAL CABLE, 345 MILS TRXLPE (100% INSULATION LEVEL) FOR COLLECTION SYSTEMS 03/14/2012 DR One Bridge Plaza North Suite 260 I Fort Lee, NJ 07024 I Tel 201 242 9906 I Fax 201 242 9926 Revision Description WTEC part number Date Submitted By E 2/0-19 added with 10x14 N Axxx-01UD35GTRxxJ 07/13/2011 SS F 4/0-19 added with 16#14, 1/2N Axxx-01UD35GTRxxJ 01/04/2012 SS G 1000 MCM added with 1/12 N Axxx-01UD35GTRxxJ 01/27/2012 SS H Updated Ampacity Values Axxx-01UD35GTRxxJ 03/14/2012 CF 5. CABLE DIMENSIONS AND CHARACTERISTICS 1/0 19 Full 16 14 345 40/75 45/80 362 1110 1460 957 186 209 1/0 19 2/3 11 14 345 40/75 45/80 362 1110 1460 902 186 209 1/0 19 1/2 8 14 345 40/75 45/80 362 1110 1460 858 186 209 1/0 19 1/3 6 14 345 40/75 45/80 362 1110 1460 840 186 209 2/0 19 Full 13 12 345 40/75 45/80 406 1155 1510 1105 188 211 2/0 19 1/2 7 12 345 40/75 45/80 406 1155 1510 991 189 2112/0 19 1/2 10 14 345 40/75 45/80 406 1155 1510 960 189 211 2/0 19 1/3 7 14 345 40/75 45/80 406 1155 1510 911 188 211 3/0 19 Full 16 12 345 40/75 45/80 456 1205 1590 1231 191 214 3/0 19 1/2 8 12 345 40/75 45/80 456 1205 1590 1079 191 214 3/0 19 1/3 9 14 345 40/75 45/80 456 1205 1590 1003 190 213 4/0 19 Full 20 12 345 40/7545/80 or 70/120512 12601660 or 17101421 271 306 4/0 19 3/4 15 12 345 40/7545/80 or 70/120512 12601660 or 1710TBD 271 306 4/0 19 1/2 10 12 345 40/7545/80 or 70/120512 12601660 or 17101231 272 3064/0 19 1/2 16 14 345 40/75 45/80 512 1260 1610 1130 272 306 4/0 19 1/3 11 14 345 40/7545/80 or 70/120512 12601660 or 17101120 272 306250 37 1/3 13 14 345 40/75 70/120 558 1335 1820 1305 296 332350 37 1/3 11 12 345 40/75 70/120 661 1435 1880 1584 356 400500 37 1/3 16 12 34540/75 or 55/9070/120 789 15652020 or 20502001 429 486500 37 1/6 12 14 34540/75 or 55/9070/120 789 15652020 or 20501844 432 486750 61 1/3 15 10 345 55/90 70/120 968 1755 2240 2623 522 606750 61 1/6 12 12 345 55/90 70/120 968 1755 2240 2483 532 6051000 61 1/3 20 10 345 55/90 70/120 1117 1900 2430 3137 591 7061000 61 1/6 16 12 345 55/90 70/120 1117 1900 2430 2832 610 7051000 61 1/9 11 12 345 55/90 70/120 1117 1866 2347 2750 617 7051000 61 1/12 20 16 345 55/90 70/120 1117 1900 2347 2700 622 7051000 61 1/12 13 14 345 55/90 70/120 1117 1900 2347 2700 622 7051250 91 1/8 15 12 345 55/105 70/120 1251 2045 2575 TBD 679 7891250 91 1/6 20 12 345 55/105 70/120 1251 2045 2575 3172 669 789StrandingJacket (min/max)Bare Phase ConductorOver Insulation, Nom.Copper NeutralSizeInsulation, Nom.Wire Size, AWGNo. of WiresOver Jacket, Nom.Size, AWG or KCMILApprox. Weight, lbs/1000 ftAmpacity*Trefoil formationFlat formationPhase Conductor Thickness in Mils Diameters in MilsInsulation shield (min/max) PRODUCT DATA SHEET 34.5 KV CONCENTRIC NEUTRAL CABLE, 345 MILS TRXLPE (100% INSULATION LEVEL) FOR COLLECTION SYSTEMS 03/14/2012 DR One Bridge Plaza North Suite 260 I Fort Lee, NJ 07024 I Tel 201 242 9906 I Fax 201 242 9926 Revision Description WTEC part number Date Submitted By E 2/0-19 added with 10x14 N Axxx-01UD35GTRxxJ 07/13/2011 SS F 4/0-19 added with 16#14, 1/2N Axxx-01UD35GTRxxJ 01/04/2012 SS G 1000 MCM added with 1/12 N Axxx-01UD35GTRxxJ 01/27/2012 SS H Updated Ampacity Values Axxx-01UD35GTRxxJ 03/14/2012 CF *The values were calculated using CYMCP 5.0 Rev. 3 by CYME International T&D with the following assumptions: 90°C conductor temperature, 100% load factor, direct buried, 36” burial depth, 25°C ambient temperature, native soil thermal resistivity is 100 °C•cm/W. Neutrals’ ends are bonded. Neutrals cross-bonded in the flat formation for phase conductors 750 KCMIL-1250 KCMIL. Cables are spaced 8” between cable centers in the flat formation. Additional ampacity values can be calculated for other assumptions by request.
Most popular related searches
