AcSoft Ltd
- Home
- Companies & Suppliers
- AcSoft Ltd
- Downloads
- ACQUA Advanced Communications Quality ...
ACQUA Advanced Communications Quality Analysis System Datasheet
04.12 D6810e7 Valid since ACQUA version 3.1.100 / Subject to changeEbertstraße 30aD-52134 HerzogenrathTel: +49 (0)2407-577-0Fax: +49 (0)2407-577-99E-mail: telecom@head-acoustics.deWEB: www.head-acoustics.deG-MOS CAR23 45N-MOS CAR2345S-MOS CAR2345G-MOS CAFE2345N-MOS CAFE2345S-MOS CAFE2345G-MOS ROAD2345N-MOS ROAD2345S-MOS ROAD2345G-MOS TRAIN2345N-MOS TRAIN2345S-MOS TRAIN234 5OVERVIEWACQUA is a dual channel analysissystem for diagnosis of acoustic and/orelectric transmission paths up to 24 kHz.By means of predefined modifiablemeasurement descriptors measurementdata can be gathered and evaluated in asimple and quick manner. All telecomspecific analyses comply with the interna-tional standards of ITU-T, ETSI, IEEE andTIA.The system includes a dual channelsignal generator and a dual channelanalyzer. In combination with measure-ment frontends a wide range of singlecomponents, complete terminals andtransmission networks can be analyzedvia fully synchronized digital in- andoutputs.A variety of options allows the indivi-dual tailoring of the software to specificfields of application which may range fromthe evaluation of frequency responses topsychacoustic models and speech qualityanalysis systems.DESCRIPTIONACQUA is a software package for Win-dows® XP / Windows® 7 for speech qualitymeasurements and analyses of components,terminals and networks. It allows the genera-tion, modification and conduction ofmeasurement sequences as well as the analy-sis, documentation and archiving of measure-ment data in the time and frequency domain.ACQUA makes use of user-definable stan-dards or standards based on national andinternational telecommunication authoritiessuch as ETSI, ITU, TIA, 3GPP, GCF, PTCRB.These standards consist of various measure-ment descriptors (SMDs) which are combinedto measurement sequences and which deter-mine how the measurement data are capturedand analyzed in the time and frequency do-main.The user can view the settings of the mea-surement descriptors in a clearly structured andcomprehensible form. The measurement de-scriptors can be modified by the user or canbe protected against modification.Reports can be generated from the mea-surement and analysis results which can beedited with Microsoft® Office (alternatively:Open Office, Libre Office).The databases can be installed on a localSQL server or a network SQL server and allowAAAAAdvanced CCCCCommunication QuQuQuQuQuality AAAAAnalysisDATA SHEETthe automatic archiving of all measurementsequences, results and reports.The high degree of automization and theease of use of ACQUA allow the fast conduc-tion of complex test suites with minimal re-quirements on user interaction.Features:• Analyses in the time domain, determina-tion of level, level vs. time, delay etc.• Analyses in the frequency domain, deter-mination of transmission functions, loud-ness ratings, echo loss, distortions, back-ground noise, out-of-band signals etc.• All telecom specific measurement meth-ods available; implemented calculationmethods according to e.g.:- ITU-T G.122 / P.64 / P.79 / P.340 / P.502 (Appendix III) / O.131 / O.132- IEEE 269Optionally, further methods are avail-able, e.g.:- 3GPP 26.132 (ANR tests)- TOSQA- PESQ (ITU-T P.862)- POLQA (ITU-T P.863)- “Relative Approach”- GCF/PTCRB- STITEL, STIPA, RASTI- SNRi & TLNR (ITU-T G.160)- 3QUEST (ETSI EG 202396-3)- EQUEST• Digital real-time equalization of any arti-ficial mouth• Individual default settings definable• Modifiable measurement descriptors• Automated measurement sequences• Creation and automatic verification oftolerance schemes• Recording of any signals via digital inter-faces (only with full-license version andcompact systems)• Acoustic real-time playback for analysissupport (e.g. via headphones)• Data integrity and reproducibility due toarchiving of measurement sequences andresults in an SQL database• Calibration of measurement system in dBV,dBSPL, dBPaAPPLICATIONS• Conformance tests• Research & development• Speech quality measurement andoptimization (algorithms and systems)• Quality control04.12 D6810e7 Valid since ACQUA version 3.1.100 / Subject to changeMEASUREMENT SIGNALSThe following measurement signals are usedby the measurement descriptors (dependingon the corresponding standard):• Sine• Sine Stepped Sweep• Multisine• Pseudo Noise• Artificial Voice (P.50)• Speech• Test signals according to ITU-T Rec. P.501,e.g. Composite Source Signal (CSS)• Any test signal can be defined and editedby the user• Any test signal can be importedPRODUCT VERSIONSACQUA Full-License (Code 6810)Full version with maximum range of fea-tures (cf. feature list on page 3).Network l icensing:Network l icensing:Network l icensing:Network l icensing:Network l icensing:• LicenseLicenseLicenseLicenseLicense: Code 6810 is not available fornetwork dongle• Options Options Options Options Options (ACOPTs, cf. below): most of theACOPTs can be booked out from a networkdongle (for an extra charge)ACQUA Workplace (Code 6830)For post-analyses, measurement prepara-tion and documentation, i.e. without the pos-sibility to start measurements. All SMD typescan be created/opened/edited, even thosewhich normally require an ACOPT or whichare taken from an (encrypted) standard.Optionally, ACQUA Workplace can be up-graded to the full-license version with “UGACQUA Workplace” (Code 6862).Main appl icat ion areas:Main appl icat ion areas:Main appl icat ion areas:Main appl icat ion areas:Main appl icat ion areas:• Expert system, for building measurementdescriptors• User system for post-analysis, report gener-ating and measurement data reappraisal(thus “relieving” the measurement room)• Verification system for customers and sup-pliers, especially for customers who do notwant to measure themselves, but want toverify tests in detail.Network l icensing:Network l icensing:Network l icensing:Network l icensing:Network l icensing:• LicenseLicenseLicenseLicenseLicense: available for network dongle (foran extra charge). Code 6830N: new license;Code 6830UGN: upgrade of existing license• Options Options Options Options Options (ACOPTs, cf. below): most of theACOPTs can be booked out from a networkdongle (for an extra charge)ACQUA Compact (Code 6860.xx etc.)This version forms part of all ACQUA Com-pact systems which are available as bundlesconsisting of software, measurement frontends, measurement standards and (if required)further components for specific measurementtasks.In comparison with the full-license version,the ACQUA Compact software is limited re-garding SMD types, result administration, re-sult editing and offline analysis.A variety of compact systems is available.Detailed information can be found in a sepa-rate data sheet on ACQUA Compact systems.Optionally, ACQUA Compact can be up-graded to the full-license version with “UGACQUA Compact” (Code 6834).Network l icensing:Network l icensing:Network l icensing:Network l icensing:Network l icensing:Network dongle and booking of optionsfrom the network dongle are not available forACQUA Compact systems.OPTIONSA variety of options allows the individualtailoring of the software to specific fields ofapplication. The currently available optionsare described in detail in a separate data sheet(D68xx). The following list therefore only givesa short summary:• ACOPT 01 (Code 6811)+ – Signal Generatorand Editor• ACOPT 02 (Code 6812)+ – Signal Analysis• ACOPT 03 - ACOPT 08 (Codes 6813 - 6818):No longer available. Can be replaced byArtemiS Suite. Details upon request.• ACOPT 09 (Code 6819)+ – SLVM P.56• ACOPT 10 (Code 6820) – TOSQA• ACOPT 11 (Code 6821)+ – CLIP• ACOPT 12 (Code 6822)+ – DTMF• ACOPT 14 (Code 6824) – TBR 21• ACOPT 15 (Code 6825) – TBR 37• ACOPT 16 (Code 6836) – PESQ• ACOPT 17 (Code 6839)+ – Relative Ap-proach• ACOPT 18 (Code 6840)+ – Remote ControlACQUA via COM Interface• ACOPT 19 (Code 6842)+ – Online Analysis• ACOPT 20 (Code 6843)+ – Quality Pie• ACOPT 21 (Code 6844) – 3QUEST• ACOPT 22 (Code 6847) – ES 203 021• ACOPT 23 (Code 6848) – GCF• ACOPT 24 (Code 6849) – PTCRB• ACOPT 25 (Code 6852)+ – PsychoacousticSMDs• ACOPT 26 (Code 6853)+ – Roomacoustics• ACOPT 27 (Code 6854)+ – Speech Transmis-sion Index (STITEL, STIPA, RASTI)• ACOPT 28 (Code 6855)+ – SNRI & TNLRCalculation acc. to ITU-T G.160 (App. II,Amd. 1)• ACOPT 29 (Code 6856) – EQUEST• ACOPT 30 (Code 6857) – POLQA• ACOPT 31 (Code 6858) – Batch CalculatorTool+ also available as network license (whenordering, add “N“ to code number for newlicenses or add “UGN“ for upgrades of existinglicenses, e.g. “Code 6855N“ for ACOPT 28new license or “Code 6855UGN“ for ACOPT28 license upgrade)Result diagram window04.12 D6810e7 Valid since ACQUA version 3.1.100 / Subject to changeData and results Full Workplace Compact Options Network Full Workplace CompactDatabase archiving ACOPT 01 Signal generator and editor ? ? ? —Report ? — ? ACOPT 02 Signal analysis ? ? ? —Analysis data ? — ? ACOPT 09 Speech level voltmeter (ITU-T P.56) ? ? ? ?Time data ? — — 1) ACOPT 10 TOSQA — ? ? ?Import/export data with conversion 2) ? ? ? ACOPT 11 CLIP (ETSI ETS 300 778-1) ? ? — —MP3 import and export ? ? — ACOPT 12 DTMF ? ? ? —Signal recording ? — ? ACOPT 14 ETSI TBR 21 — ? — —Create report 3) ? ? ? ACOPT 15 ETSI TBR 37 — ? — —Edit results with ACQUAlyzer ? ? — ACOPT 16 PESQ (ITU-T P.862) — ? ? ?Access ACOPTs from network dongle ? ? — ACOPT 17 Relative Approach ? ? ? ?Number of measurement objects per project unlimited unlimited 2 ACOPT 18 Remote control via COM interface ? ? ? ?ACOPT 19 Online analysis ? ? ? —Single measurement descriptors Full Workplace Compact ACOPT 20 Quality pie (ITU-T P.505) ? ? ? ?Create and edit SMDs ? ? ? ACOPT 21 3QUEST (ETSI EG 202 396-3) — ? ? ?Basic SMD types 4) ? ? ? ACOPT 22 ETSI ES 203 021 — ? — —Special SMD types ACOPT 23 GCF — ? — ?3QUEST (ETSI EG 202 396-3) ? 21 ? 21 ? 21 ACOPT 24 PTCRB — ? — ?Active speech level (ITU-T P.56) ? 09 ? 09 ? 09 ACOPT 25 Psychoacoustics (ISO 532 A/B · DIN 45631) ? ? ? ?Call impedance ? 14 — — ACOPT 26 Room acoustics (ISO 3382 · ITU-T P.340) ? ? ? ?CLIP ? 11 — — ACOPT 27 Speech transmission index (IEC 60268-16) ? ? ? ?Digital multimeter ? 14 — — ACOPT 28 SNR improvement (ITU-T G.160) ? ? ? ?DTMF ? 12 ? 12 — ACOPT 29 EQUEST — ? ? ?EQUEST ? 29 ? 29 ? 29 ACOPT 30 POLQA (ITU-T P.863) — ? ? ?MOS — Listening speech quality ACOPT 31 Batch Calculator Tool — ? 5) ? 5) —PESQ (ITU-T P.862) ? 16 ? 16 ? 16POLQA (ITU-T P.863) ? 30 ? 30 ? 30 ? IncludedTOSQA ? 10 ? 10 ? 10 ? OptionalPsychoacoustics (ISO 532 A/B · DIN 45631) ? 25 ? 25 ? 25 ? xx Optional, requires ACOPT xxPulse dialing ? 14 — — ? AvailableRelative Approach ? 17 ? 17 ? 17 — Not availableRoom acoustics (ISO 3382 · ITU-T P.340) ? 26 ? 26 ? 26SNR improvement (ITU-T G.160) ? 28 ? 28 ? 28Speech transmission index (IEC 60268-16) ? 27 ? 27 ? 27Voltage vs current ? 14 — —Wideband noise analysis ? 14 — —1) Time data can be archived for the following SMD types: Time response · 3QUEST · EQUEST · MOS (TOSQA · PESQ · POLQA)2) Conversion to and from the following formats: ASCII · Wave · MS Excel (*.xls) · Matlab · PCM3) Requires Microsoft Word, Open Office or Libre Office4) Analysis file operations · Automated double talk (ITU-T P.502 Appendix III) · Calculate single value · Correlation and transfer function · Delay (Two-frequency method · Cross correlation) · Distortion (Noise [ITU-T O.131 · IEEE 269-2010] · Sinusoidal · Fast sinusoidal) · Echo loss · Frequency response · Level · Level vs time · Loudness rating · Noise · Out of band · Play file · Return loss and longitudal conversion loss · Script · Sidetone masking rating · Text (info) · Time distance · Time response · Variation of level · Variation of loudness rating5) For 3QUEST, EQUEST, PESQ, POLQA, SNRI, and TOSQA, the respective ACOPTs (21, 29, 16, 30, 28, and 10) are needed in addition.For automated double talk, no ACOPT is needed in addition.FEATURE LISTThe following table gives an overview of the differences regarding the support of various features in the three versions “Full-License“ (Code6810), “Workplace“ (Code 6830 and 6830N) and “Compact“ (Code 6860.xx etc.), as well as showing the ACOPTs available as network license:Signal editor window (requires ACOPT 01)04.12 D6810e7 Valid since ACQUA version 3.1.100 / Subject to changerepresented byDELIVERY ITEMSThe ACQUA version „Full-license“ (Code6810) includes the following delivery items:• ACQUA Setup DVDfor Windows® XP / Windows® 7 (Germanor English version) including comprehen-sive, context-sensitive help system• Local Dongle (for USB port)• SMA 1 year software maintenance andupdate contract (optionally renewable ona yearly basis)The ACQUA version „Workplace“ (Code6830) additionally includes the ACQUAoption ACOPT 02 and the digital soundboard DSB II (Code 2406). Optionally, anetwork dongle is available instead of thelocal dongle (upon request, at an extra charge).The ACQUA Compact systems (Code6860.xx etc.) are bundles consisting of com-pact software, measurement front ends, mea-surement standards and (if required) furthercomponents for specific measurement tasks.The individual delivery items are described ina separate data sheet.ACCESSORIESThe following accessories are optionallyavailable:• DSB II (Code 2406): digital sound board(PCI)• DSB III (Code 2407): digital soundboard (PCIe)• Multiple Serial Card RS232 (PCI)Depending on the measurement task, oneor several front ends (MFEs) are required fordata acquisition and measurement control.Moreover, measurements standards, artificalhead with handset positioner and othercomponents may be required.If ACQUA is installed on notebooks, thedigital sound board (DSB) cannot be used.Instead, the use of PEQ V (Code 2492) orMFE VI.1 (Code 6462) is required.SYSTEM REQUIREMENTSThe PC which ACQUA is installed on hasto fulfill the following minimum specifications:• Pentium IV compatible processor with 2.0GHz or faster• Min. 1 GB RAM (2 GB or morerecommended)• NTFS file system required• Free hard disk capacity required forinstallation of all components: 1 GB• Free hard disk capacity required forACQUA databases: depending on thenumber and size of your databases• Min. 2 unused USB ports (3 ore morerecommended).• For use of MFE II and soundboard: 2 freePCI slots required• Microsoft® Windows® XP Professional SP3(x86 = 32bit) or Windows® 7 Professional(x86 = 32bit or x64 = 64bit), English orGerman version, including all currentservice packs• Microsoft® Office (XP or higher), Englishor German version, including all currentservice packs. Note: the OEM version„Microsoft® Office Starter“ is not suitablefor ACQUA due to a lacking COMinterface support.Alternatively: Open Office or Libre OfficeIntuitive hardware configuration and front end controlWide range of analysis possibilities in ACQUAlyzerLegal Notes / Notes on Trademarks:Microsoft® and Windows® are registered trade-marks of the Microsoft Corporation.POLQA® is a registered trademark ofOPTICOM GmbH.PESQ® is a registered trademark of OPTICOMGmbH and Psytechnics Ltd..All other brand and product names are trade-marks and/or registered trademarks oftheir respective owners.This information may be subject to change.© 2012 HEAD acoustics GmbH. All rights re-served.
Most popular related searches
