HF scientific, Inc.
- Home
- Companies & Suppliers
- HF scientific, Inc.
- Downloads
- AdvantEDGE - Communications Adapter ...
AdvantEDGE - Communications Adapter Datasheet
ORPpHTurbidityDissolved OxygenFree ChlorineDissolved OzoneConductivityOptical Dissolved Oxygenonline measurement electrodesFor three decades HF scientific has developed specialized expertise in measurements for water quality. Our original involvement in water-quality focused on Turbidity measurement. These products have positioned us as one of the worldwide leaders in Turbidity measurement and monitoring. Over the years our expertise expanded to include devices for monitoring other parameters such as Residual Chlorine, Streaming Current and UV% Transmission. We are now excited to expand our product offering with the addition of our new AdvantEDGE Series™ of measurement electrodes. These electrode systems have been designed to reduce equipment and installation costs while improving reliability. Measurement parameters include pH, ORP, Free Chlorine, Raw Water Turbidity, Dissolved Oxygen, Optical Dissolved Oxygen, Dissolved Ozone, Contacting Conductivity and Toroidal Conductivity.The AdvantEDGE Series™ systems feature factory pre-calibrated electrodes. The electrodes can subsequently be checked for calibration, diagnosed and configured directly from a PLC or other computer system (e.g., SCADA). Although they are available for use if desired, a local display/analyzer is not necessary.Numerous integrated communications protocols are supported, including Modbus RTU, RS-232, RS-485 ASCII, Profibus, CANOpen, DeviceNet, Ethernet IP, and USB.Contact us directly or call the HF scientific representative serving your area to learn how the new AdvantEDGE Series™ can bring your facility into a new generation of water quality monitoring. HF scientific3170 Metro ParkwayFt. Myers, FL 33916Ph: 239-337-2116 • Fax: 239-332-7643Toll Free: 888-203-7248www.hfscientific.comTable of Contents: AdvantEDGE series™ Overview ............................................................. 1 pH ............................................................................................................... 2 ORP ............................................................................................................ 2Dissolved Ozone ................................................................................... 3 Dissolved Oxygen .................................................................................... 3 Optical Dissolved Oxygen ....................................................................... 4 Contacting Conductivity .......................................................................... 5 Toroidal Conductivity ............................................................................... 5 Free Chlorine Panel System .................................................................... 6 Turbidity .................................................................................................... 6 LD500 Local Display ................................................................................ 7 PA500 Profibus Gateway ......................................................................... 7 Mounting Hardware .................................................................................. 8 Accessories & Replacement Parts ......................................................... 8AdvantEDGE series™Specifications and Content Information Subject to change without notice03-17-2011 Rev 0.71AdvantEDGE series™PARAMETERSpHORPFree ChlorineTurbidityDissolved OxygenDissolved OzoneConductivityINTERFACEDirect Local DisplayCOMMUNICATIONS PROTOCOLSModbus RTUProfibusRS 485 ASCIICANOpenDevice NetEthernet IPUSBCONTROLROOMSCADAPLCDCSPCThe AdvantEDGE sensor assembly consists of three components designed for direct connection to control systems without the need for intermediate analyzer electronics. A Communications Module plugs into the back of the Interface Module and provides direct interactive communication of measurement, configuration, calibration and diagnostic information with computers and networks. A full family of sensor heads plug into the front of the Interface Module and automatically provides calibrated, high resolution measurements.Communications AdapterProvides power and direct interactive communication with control systems and computers.A selection of plug and play communication modules provide power and direct interactive communications with control systems and computers. The table below shows the available protocols. If a local display is desired, the LD500 can be used. Multiple sensor assemblies can be used with the LD500. Interface ModuleThe heart of the sensor assembly is the Universal Interface Module. It’s encapsulated measurement electronics automatically converts sensor signals into calibrated measurement units. It works with a variety of Communication Modules to operate directly with any computer system.Sensor HeadPre-calibrated plug and play sensor heads can be replaced at any time, making AdvantEDGE the most versatile and accurate analytical measurement system on the market. The table below shows the parameters available. Optional LD500 Local DisplayTypical AdvantEDGE System Assembly03-17-2011 Rev 0.72Measurement System PerformanceRange: -2100mV to +2100mVResolution: 0.1mVAccuracy: 0.1% of readingStep Response Time: 90% in 30 secondsNote: Typical at 25°CPerformance unaffected by cable lengthOperational EnvironmentTemperature Range: -5°C to 95°C Maximum Pressure: 100 psi @ 95°C 85 psi @ 75°CMaximum Flow Rate: 10 ft/secondPower RequirementsVoltage Range: 10 to 30 VDCMaximum Power: 200 mWTypical Power: 120 mWNote: Class II DC power supply requiredConstructionProcess Electrodes: Platinum or GoldGround Rod: Titanium, 316 Stainless Steel or Hastelloy CO-Rings: Viton® (other materials available)Units of MeasureMeasurement Units: mVTemperature Units: °C, °FCalibrationSample: 1 pointTemperature: 1 and 2 pointNote: ORP and temperature are precalibrated at the factoryTemperature Compensation OptionsTemperature measurement is provided as an independent measurement.Note: Temperature can be entered manuallyOther Configuration OptionsSensor Filter: 0 to 100 secondsTemperature Filter: 0 to 100 secondsApprovals and RatingsImmunity & Emissions: CE (EN61326 and EN61326:1998)Safety: CE (EN 61010-1) UL 508Hazardous Locations: UL Class I, Division 2AdvantEDGE pH• Differential pH measurement• Pre-calibrated (no field calibration required)• Plug & play sensor heads• Replaceable quad junction salt bridges• Electrode protection options• Direct data reporting• Plug & play industrial communications adaptersConnect this pH sensor to a PLC for seamless integration with industrial control systems. Use any computer to display data, calibrate and customize the measurement without an intermediate analyzer electronics box. A LD500 local display can be used if desired. Sensor heads are pre-calibrated and can be replaced or exchanged with any other type of sensor without taking the system down. Save space, time and money.ConstructionProcess Electrodes: “G”, “HF” or Low Temperature GlassGround Rod: Titanium, 316 Stainless Steel or Hastelloy CO-Rings: Viton® (other materials available)Units of MeasureMeasurement Units: pH, mVTemperature Units: °C, °FCalibrationAutomatic Buffer: 1 and 2 pointSample: 1 and 2 pointTemperature: 1 and 2 pointNote: pH and temperature are precalibrated at the factoryTemperature Compensation OptionsLinear: % per °CBuilt-in tables: Ammonia or MorpholineNote: Temperature can be entered manuallyOther Configuration OptionsSensor Filter: 0 to 100 secondsTemperature Filter: 0 to 100 secondsAuto Calibration BufferStandards: (4, 7, 10) and DIN 19267Approvals and RatingsImmunity & Emissions: CE (EN61326 and EN61326:1998)Safety: CE (EN 61010-1) UL 508Hazardous Locations: UL Class I, Division 2Measurement System PerformanceRange: 0 to 14 pHResolution: 0.01 pHAccuracy: 0.014 pHStep Response Time: 90% in 30 secondsNote: Typical at 25°CPerformance unaffected by cable lengthOperational EnvironmentTemperature Range: -5°C to 95°C Maximum Pressure: 100 psi @ 95°C 85 psi @ 75°CMaximum Flow Rate: 10 ft/secondPower RequirementsVoltage Range: 10 to 30 VDCMaximum Power: 200 mWTypical Power: 120 mWNote: Class II DC power supply requiredAdvantEDGE ORP• Differential ORP measurement• Pre-calibrated (no field calibration required)• Plug & play sensor heads• Replaceable quad junction salt bridges• Electrode protection options• Direct data reporting• Plug & play industrial communications adaptersConnect this ORP sensor to a PLC for seamless integration with industrial control systems. Use any computer to display data, calibrate and customize the measurement without an intermediate analyzer electronics box. A LD500 local display can be used if desired. Sensor heads are pre-calibrated and can be replaced or exchanged with any other type of sensor without taking the system down. Save space, time and money.03-17-2011 Rev 0.73Measurement System PerformanceRange: 0 to 40 ppmResolution: 0.01 ppmAccuracy: 0.04 ppmStep Response Time: 90% in 90 secondsNote: Typical at 25°CPerformance unaffected by cable lengthOperational Environment PEEK® Sensor Head Temperature Range: -5°C to 50°C Maximum Pressure: 150 psi @ 50°C Maximum Flow Rate: 10 ft/second Power RequirementsVoltage Range: 10 to 30 VDCMaximum Power: 200 mWTypical Power: 120 mWNote: Class II DC power supply requiredConstructionProcess Electrodes: Gold Cathode, Silver Anode, Silver Reference (3 Electrode Polarographic Clark Cell)Guard: PlatinumMembrane: PFA TeflonO-Rings: Viton® (other materials available)Units of MeasureMeasurement Units: ppm, mg/l, %Temperature Units: °C, °FCalibrationAir: Automatically adjusts for set pressureSample: 1 pointZero: 1 pointTemperature: 1 and 2 pointNote: D.O. and temperature are precalibrated at the factoryOther Configuration OptionsSensor Filter: 0 to 100 secondsTemperature Filter: 0 to 100 secondsApprovals and RatingsImmunity & Emissions: CE (EN61326 and EN61326:1998)Safety: CE (EN 61010-1) UL 508Hazardous Locations: UL Class I, Division 2AdvantEDGE Ozone• Clark Cell technology• Pre-calibrated (no field calibration required)• Plug & play sensor heads• Rugged four resistant membrane• Electrode protection options• Simple membrane cartridge replacement• Direct data reporting• Plug & play industrial communications adaptersConnect this Dissolved Ozone sensor to a PLC for seamless integration with industrial control systems. Use any computer to display data, calibrate and customize the measurement without an intermediate analyzer electronics box. A LD500 local display can be used if desired. Sensor heads are pre-calibrated and can be replaced or exchanged with any other type of sensor without taking the system down. Save space, time and money.AdvantEDGE DO• Clark Cell technology• Pre-calibrated (no field calibration required)• Plug & play sensor heads• Rugged four resistant membrane• Electrode protection options• Simple membrane cartridge replacement• Direct data reporting• Plug & play industrial communications adaptersConnect this Dissolved Oxygen sensor to a PLC for seamless integration with industrial control systems. Use any computer to display data, calibrate and customize the measurement without an intermediate analyzer electronics box. A LD500 local display can be used if desired. Sensor heads are pre-calibrated and can be replaced or exchanged with any other type of sensor without taking the system down. Save space, time and money.Measurement System PerformanceRange: 0 to 40 ppmResolution: 0.01 ppmAccuracy: 0.04 ppmStep Response Time: 90% in 90 secondsNote: Typical at 25°CPerformance unaffected by cable lengthOperational Environment PEEK® Sensor Head Temperature Range: -5°C to 50°C Maximum Pressure: 150 psi @ 50°C Maximum Flow Rate: 10 ft/second Power RequirementsVoltage Range: 10 to 30 VDCMaximum Power: 200 mWTypical Power: 120 mWNote: Class II DC power supply requiredConstructionProcess Electrodes: Gold Cathode, Silver Anode, Silver Reference (3 Electrode Polarographic Clark Cell)Membrane: FEP TeflonO-Rings: Viton® (other materials available)Sensor Head Material: PEEK®Units of MeasureMeasurement Units: ppm, mg/l, %Temperature Units: °C, °FCalibrationAir: Automatically adjusts for set pressureSample: 1 pointZero: 1 pointTemperature: 1 and 2 pointNote: D.O. and temperature are precalibrated at the factoryOther Configuration OptionsSensor Filter: 0 to 100 secondsTemperature Filter: 0 to 100 secondsApprovals and RatingsImmunity & Emissions: CE (EN61326 and EN61326:1998)Safety: CE (EN 61010-1) UL 508Hazardous Locations: UL Class I, Division 203-17-2011 Rev 0.74AdvantEDGE Optical Dissolved Oxygen• Robust• Cost Effective Options• No Calibration Hassles• Low Maintenance• AccurateThe AdvantEDGE sensor uses the latest technology to measure dissolved oxygen (DO) in demanding environments. The AdvantEDGE series™ Optical Dissolved Oxygen RDO® sensor o ffers several advantages for monitoring DO in process applications: Sensor Type Luminescent dissolved oxygen sensorTransmitter/local display Optional, not requiredRange 0 to 20 mg/L concentration 0 to 200% saturationAccuracy (DO) ±0.1 mg/L, 0 to 8 mg/L ±0.2 mg/L, 8 to 20 mg/LResponse time, cap T90: 30 sec T95: 37 sec @ 25°CResolution 0.01 mg/LUsage life of cap 1 year from the first instrument readingShelf life of cap 2 years from date of manufacture (install within 1 year from date of manufacture)Operating temperature 0° to 50° (32° to 122°F)IP rating IP-67 with cap off , IP-68 with cap installedCompliance Heavy industrial, IEC 61000-6-2:2005Storage conditions, cap 1° to 60° (33° to 140°F), in factory containerStorage conditions, sensor -5° to 60° (23° to 140°F)Salinity range 0 to 42 PSU, fi xed or real-time capablepH range 2-10 pHBarometric range 507-1115 mbar, fi xed or real-time capableInternal mounting thread 1¼-11½ NPTCommunications options Modbus RTU (RS485), 4-20mA, SDI-12Maximum cable length Up to 4000 ft (Modbus and 4-20 mA) or up to 200 ft (SDI-12)Warranty Sensor: 3 years from date of manufacture Cap: 2 years from date of manufacture The AdvantEDGE sensor measures dissolved oxygen (DO) using the principle of “dynamic luminescence quenching.” The sensor (Figure 1) uses lifetime-based optical fluorescent technology to provide an extremely stable, accurate, low-maintenance DO sensor. The sensor measures the “phase” (or delay) of the returned signal compared to the excitation signal, and is thus based on the “lifetime” rather than the “intensity” of the luminescence. The presence of oxygen in the foil quenches the luminescence and causes a phase shift in the returned signal, detected by the photodiode. The phase difference between the blue excitation light and the return red light is measured, and the result is used to quantify DO.Photodiodefor Sensor DiagnosticsFigure 1: AdvantEDGE sensor designSpecifications03-17-2011 Rev 0.75AdvantEDGE Contacting Conductivity• High resolution measurement• Pre-calibrated (no field calibration required)• Plug & play sensor heads• 0 to 2 S/cm range• Direct data reporting• Plug & play industrial communications adaptersConnect this Conductivity sensor to a PLC for seamless integration with industrial control systems. Use any computer to display data, calibrate and customize the measurement without an intermediate analyzer electronics box. A LD500 local display can be used if desired. Sensor heads are pre-calibrated and can be replaced or exchanged with any other type of sensor without taking the system down. Save space, time and money.Measurement System PerformanceRange: 0 to 2,000,000 uS/cm (2 S/cm)Resolution: 4.5 significant digitsAccuracy: 0.1% of readingStep Response Time: 90% in 30 secondsNote: Typical at 25°CPerformance unaffected by cable lengthOperational Environment CPVC Sensor Head Temperature Range: -5°C to 50°CMaximum Pressure: 85 psi @ 50°CMaximum Flow Rate: 10 ft/secondPower RequirementsVoltage Range: 10 to 30 VDCMaximum Power: 200 mWTypical Power: 120 mWNote: Class II DC power supply requiredConstructionCell Constants: 0.1 for Resistivity 1.0 and 5.0 for ConductivityO-Rings: Viton® (other materials available)Electrode Material: Titanium (Standard) or 316 Stainless SteelWeight: 1.2 lbsUnits of MeasureMeasurement Units: µS/cm, TDS, %, MO • cmTemperature Units: °C, °FCalibrationZero: In dry airSpan: 1 pointTemperature: 1 and 2 pointNote: Conductivity and temperature are precalibrated at the factoryOther Configuration OptionsSensor Filter: 0 to 100 secondsTemperature Filter: 0 to 100 secondsConcentration Table: User 10-pointApprovals and RatingsImmunity & Emissions: CE (EN61326 and EN61326:1998)Safety: CE (EN 61010-1) UL 508Hazardous Locations: UL Class I, Division 2AdvantEDGE Toroidal Conductivity• High resolution measurement• Pre-calibrated (no field calibration required)• Plug & play sensor heads• 0 to 2 S/cm range• Direct data reporting• Plug & play industrial communications adaptersConnect this Toroidal Conductivity sensor to a PLC for seamless integration with industrial control systems. Use any computer to display data, calibrate and customize the measurement without an intermediate analyzer electronics box. A LD500 local display can be used if desired. Sensor heads are pre-calibrated and can be replaced or exchanged with any other type of sensor without taking the system down. Save space, time and money.Measurement System PerformanceRange: 0 to 2,000,000 uS/cm (2 S/cm)Resolution: 4.5 significant digitsAccuracy: 0.1% of readingStep Response Time: 90% in 30 secondsNote: Typical at 25°CPerformance unaffected by cable length PEEK® CPVC Sensor Head Sensor Head Temperature Range: -5°C to 50°C -5°C to 50°CMaximum Pressure: 150 psig @ 50°C 85 psig @ 50°CMaximum Flow Rate: 10 ft/second 10 ft/secondPower RequirementsVoltage Range: 10 to 30 VDCMaximum Power: 200 mWTypical Power: 120 mWNote: Class II DC power supply requiredConstructionO-Rings: Viton® (other materials available)Sensor Head Material: CPVC, Peek®Weight: 1.2 lbs (Peek®, Ryton® or CPVC) 2.6 lbs (with 316 Stainless Steel interface module)Units of MeasureMeasurement Units: µS/cm, TDS, % conc.Temperature Units: °C, °FCalibrationZero: In dry airSpan: 1 pointTemperature: 1 and 2 pointNote: Conductivity and temperature are precalibrated at the factoryOther Configuration OptionsSensor Filter: 0 to 100 secondsTemperature Filter: 0 to 100 secondsConcentration Table: User 10-pointApprovals and RatingsImmunity & Emissions: CE (EN61326 and EN61326:1998)Safety: CE (EN 61010-1) UL 508Hazardous Locations: UL Class I, Division 203-17-2011 Rev 0.76AdvantEDGE Free Chlorine Panel• Free Chlorine• Amperometric Measurement• Temperature Compensated• Optional pH Correction• Pre-Calibrated• Plug & Play• Rugged Teflon Membrane• Replaceable Membrane Cap• Remote Measurement, Calibration, Configuration, and Diagnostics.This Free Chlorine sensor will measure accurately in processes that are between 4 and 8 pH. When used with the LD500 Local Display unit and a pH measurement system, hypochlorous acid (HOCL) and hypochlorite ion (OCL-) concentration can be used to determine free chlorine present.Measurement System Preformance:Ranges: 0 to 5 ppm and 0 to 20 ppmResolution: 0.005 ppmAccuracy: 2% or +/- 10 ppb (whichever is greater)Step Response Time: 90% in 90 secondsOperational Environment:Temperature Range: 0°C to 45°C (32°F to 113°F)Maximum Pressure: 15 psig @ 45°CSystem Flow in Chamber: 200 to 250ml/min Power Requirements:Voltage Range: 10 to 30 VDCMaximum Power: 200 mWTypical Power: 120 mWNote: Class II DC power supply requiredConstruction:Process Electrodes: Gold Cathode, Silver Anode.Membrane: TeflonO-Rings: VitonSensor Head Material: Noryl®AdvantEDGE Material: CPVC or PEEK®Weight: 1.2 lbsUnits of Measure:Measurement Units: ppm, mg/l free chlorineTemperature Units: °C, °FCalibration:Sample: 1 pointZero: 1 pointTemperature: pointNote: Precalibrated at the factoryOther Configuration Options:Sensor Filter: 0 to 100 secondsTemperature Filter: 0 to 100 secondsApprovals and Ratings: Immunity and Emissions: CE Certified 89/336/EEC:CISPER 11, EN61000 (-4-2,-4-3,-4-4,-4-6, 4-8) Safety: cULus Listed; 367G E303570Hazardous Locations: Haz Loc Class 1, Division 2,Groups A, B, C, D. Max Ambient 50 °C• 0 to 4000 NTU measurement range• Conforms to ISO 7027• 90 degree and 180 degree light paths• Rugged, foul resistant construction• Local and Remote configuration and diagnostics• Temperature measurement included• Direct data reporting• Plug & play industrial communications adaptersConnect this Raw Water Turbidity sensor to a PLC for seamless integration with industrial control systems. Use any computer to display data, calibrate and customize the measurement without an intermediate analyzer electronics box. A LD500 local display can be used if desired. Measurement System Performance:Range: 0 TO 4000 NTUResolution: 0.1 NTUAccuracy: 0.2 NTUStep Response Time: 90% in 15 secondsNote: Typical at 25 C; Performance unaffected by cable length.Operational Environment:Temperature Range: -5 to 50 C Maximum Pressure: 150 psi @ 50 C Maximum Flow Rate: 10 ft./Sec. Power Requirements:Voltage Range: 10 to 30 VDCMaximum Power: 200 mWTypical Power: 120 mWNote: Class II DC power supply requiredConstruction:Windows: Quartz or Sapphire Optical Topology: Multi-Color SourceO-Rings: Viton® (other materials available)Sensor Head Material: Polycarbonate Weight: 1.2lbsUnits of Measure:Measurement Units: Turbidity Mode: NTU Sediment mode: mg/l % Temperature Units: C, FCalibration:Sample: 1 pointZero: 1 pointTemperature: 1 and 2 pointNote: Turbidity and temperature are precalibrated at the factoryMeasurement Modes:Turbidity: 90 degree/ 180 degree, narrow beam, IR lightSediment Load: Blue to IR spectrum detected at 90 degrees and 180 degrees Temperature: Automatic from -5 to 50 COther Configuration Options:Sensor Filter: 0 to 100 secondsTemperature Filter: 0 to 100 secondsApprovals and Ratings: Immunity and Emissions: CE Certified 89/336/EEC:CISPER 11, EN61000 (-4-2,-4-3,-4-4,-4-6, 4-8) Safety: cULus Listed; 367G E303570Hazardous Locations: Haz Loc Class 1, Division 2,Groups A, B, C, D. Max Ambient 50 °CAdvantEDGE Turbidity03-17-2011 Rev 0.77AdvantEDGE LD500 Local DisplayFunctions and Features• Connects to any AdvantEDGE system.• Convenient 1/4 DIN enclosure• Display sensor and temperature data• Menu Functions: Calibration, Configuration and Diagnostics• Digital Protocol Options for remote measurement, calibrations, configurations, and diagnostics.• One 4 to 20 mA loop output (Standard)• Two 4 to 20 mA loop outputs (Optional)• Two form C relays for alarm, control, and wash (Optional)• PID for pH• 7 Conduit knockouts for easy cablingMounting Options• Conduit Box, NEMA 4X (Standard)• 1/2 DIN NEMA 4X Panel Mount (Optional)Interface• Display: 2 line by 16 character LCD• Backlight: high contrast green• Keypad: 4 directional arrows, MENU, ESCAPE, and ENTEREnviromental Conditions• Ambient Operating Temperature Range: -20 to 65 C• Maximum Relative Humidity: 95% non-condensing• Meets CE requirements for heavy industrial use.• Nema 4X housing.AdvantEDGE Sensor ConnectionsSupports 1 to 255 Modbus RTU AdvantEDGE sensors of any type. • Supported Sensors: pH, ORP, Two Electrode Conductivity, Two electrode resistivity, Toroidal Conductivity, Dissolved Oxygen, Ozone, Turbidity, and Free Chlorine.4 to 20 mA Current Loop Options• One Isolated Current Loop (Standard)• Two Isolated Current Loops (Optional)• Assignable Parameters• PID function when pH parameter selected• Loop power provided by LD500Relays/Optional• Two 1 Amp form C relays with NO and NC contacts.• Assignable Parameters• Configured for Alarm, Control, & Timer FunctionsDigital Communication Options to Host Computer Network• MODBUS RTU• Device Net• Profibus DP/V1• RS-232 ASCII• RS-232 DF1• RS485 ACSII• CANOpen• Others: Consult FactoryPower SupplyInput: 10 to 30 VDC; 100 to 240 VAC optionalPower: 2W at 25 CAdvantEDGE PA500 Profibus GatewayPA500 Profibus Gateway Adapter connects up to 30 Modbus Communications Modules to a Profibus DP (V0 or V1) network with M12 connector. Full-featured measurement, calibration, configuration and diagnostics. 24 VDC power.03-17-2011 Rev 0.78Material• Immersion• PVC1 Inch Immersion Mounting with Junction BoxMaterial• CPVC• 316 Stainless SteelMaterial• CPVC• 316 Stainless SteelMaterial• CPVC (Low) • 316 Stainless Steel (Low)• CPVC (High) • 316 Stainless Steel (High)Material• 316 SS (closed)• 216 SS (open)Mounting OptionsAccessories & Replacements PartsSalt Bridge ReplacementsSBS01: PEEK® ProtectedSBS02: PEEK® FlatSBS03: CPVC ProtectedSBS04: CPVC FlatSBC01: Storage capwith spongepH SolutionsRCS03: storage solution, 60 mlPHSOL4: Buffer, 500 mlPHSOL7: Buffer, 500 mlPHSOL10: Buffer, 500 mlRCSO1-500: Reference Cell Solution 500 mlpHORPDissolved Oxygen ConductivityTurbidityDissolved OzoneSalt Bridge ReplacementsSBS01: PEEK® ProtectedSBS02: PEEK® FlatSBS03: CPVC ProtectedSBS04: CPVC FlatSBC01: Storage capwith spongeORP SolutionsRCS04: ORP storage solution, 60 mlORPSOL200: 200mV Calibration, 500 mlORPSOL600: 600 mv calibration, 500 mlRCS01: Reference cell solution, 500 mlSBC01: Storage capwith spongeOzone MembraneReplacementsDMR05: Ryton ProtectedDMR06: Ryton FlatDMR07: PEEK ProtectedDMR08: PEEK FlatSBC01: Storage capwith spongeOzone Solutions500 ml bottlesRDOK2: Ozone ElectrolyteZDOKO: Zero PowderWash Adapters MH1142: air purge, CPVCMH1132: water purge, CPVCTurbidity Solutions500 ml bottlesFOR4K: 4000 NTU Formazin Stock 500 mlFROO4O: 40 NTU Cal Kit Conductivity Solutions500 ml bottlesSOL1000: 1000 µS/cm Calibration SolutionSOL2000: 2000 µS/cm Calibration SolutionSOL5000: 5000 µS/cm Calibration SolutionSOL2C: Conductivity Electrode Cleaner1 Inch Tee Mounting 1.5 Inch Union Mounting 1.5 Inch Ball MountingSanity Mount Handrail Mounting AssemblyMaterial: PVCWash Adapters MH1142: air purge, CPVCMH1132: water purge, CPVCWash Adapters MH1142: air purge, CPVCMH1132: water purge, CPVCD.O. MembraneReplacementsDMR01: Ryton ProtectedDMR02: Ryton FlatDMR03: PEEK ProtectedDMR04: PEEK FlatAccessories & Replacements PartsHF scientific 3170 Metro Parkway, Ft. Myers FL 33916 • ph: (239)-337-2116 • fax: (239) 332-7643 • Toll Free: 888-203-7248 3-17-2011 Rev 0.7
Most popular related searches
