Aerodyne Research, Inc.

Aerodyne - CAPS PMex Monitor - Brochure

AERODYNE RESEARCH, Inc.AERODYNE RESEARCH, Inc. 45 MANNING ROAD, BILLERICA, MA 01821 (978) 663-9500 www.aerodyne.com (OCT 2010)Accurate and Precise Continuous Monitoring of Particle Optical Extinction.APPLICATIONS:• Visible (red, green or blue) measurement of particle optical extinction using patented Cavity Attenuated Phase Shift technology.• Measurement of ambient optical extinctions at the 1 Mm-1 level.• Climate Change Research Optical Properties Closure.• Roadside Monitoring.• Combustion Plume Analysis.• Aircraft Engine Exhaust Monitoring.CAPS PMex MONITOR12840Extinction (Mm-1)8/23/10 8/25/10 8/27/10 8/29/10 = 530 nmEstes Park, COMeasured particle extinction at 630 nm in Pasadena, CA during the CalNex campaign shown as 1 hour average values.Note the diurnal variation in extinction levels. Measured particle extinction at 532 nm outside of Estes Park, CO shown as 1 minute averages. Note the low levels of ambient particle extinction. The spikes are particulate emissions from passing vehicles. 250200150100500Extinction (Mm-1) 5/21/10 5/31/10 6/10/10= 630 nmPasadena, CAADVANTAGES:• Choice of 1 of 3 Wavelengths: Red (630 nm) Green (525 nm) Blue (450 nm)• No calibration required.• Autonomous Operation: No Zero Air. Automated Background Subtraction.• Linear Response (0 - 4000 Mm-1).• Maintenance-Free.AERODYNE RESEARCH, Inc.AERODYNE RESEARCH, Inc. 45 MANNING ROAD, BILLERICA, MA 01821 (978) 663-9500 www.aerodyne.com (OCT 2010)SPECIFICATIONS:Sensitivity (S/N =3) 2.5 Mm-1 (1 s), 0.25 Mm-1 (60 s)Response Time (10-90%) < 2 sSample Flow 0.85 l min-1 (volumetric flow)Operating Pressure AmbientMaterials Exposed to Sample: Copper, Stainless Steel and Aluminum Data Output: RS-232 (Data acqusition and instrument control software provided) On-Board Data Storage (800 MB) – Download through USB Port Front Panel DisplaySize/Weight: Rack mount, 19” x 24”, 25 lbs [61 cm x 43 cm x 23 cm, 12 kg] Electric Power: 50 W; 100-250 VAC (50-60 Hz) REFERENCES “Aerosol light extinction measurements by Cavity Attenuated Phase Shift Spectroscopy (CAPS): laboratory valida-tion and field deployment of a compact aerosol extinction monitor,” P.Massoli, P. Kebabian, T. Onasch, F. Hills, and A. Freedman, Aerosol Sci. Technol., 44:428–435 (2010) “System and method for trace species detection using cavity attenuated phase shift spectroscopy with an incoherent light source”, P.L. Kebabian and A. Freedman, U.S. Patent No. 7301639 (issued November 27, 2007) “Optical Extinction Monitor Using CW Cavity Enhanced Detection”, P.L. Kebabian, W.A. Robinson and A. Freedman, Rev. Sci. Instrum., 78, 063102 (2007) CAPS PMex MONITOR
Most popular related searches