Agilent Technologies, Inc.

Agilent J&W - GC & GC/MS - Plot PT Columns Featured Brochure

Reduce maintenance cost for routine PLOT column analysis and extend capabilities with capillary flow technology and GC/MSParticle shedding of the stationary phase can make it challenging to use porous layer open tubular (PLOT) columns. When particles dislodge from the column and flow downstream, the results can be flow restriction or plugging of the GC flow path, damage to column switching valves, and detector contamination. Particles entering the detector can cause signal spikes which can interfere with the software’s ability to identify and quantitate compounds. The use of Agilent Capillary Flow Technology (CFT) and GC/MS analysis using PLOT columns has been limited due to these issues. Some labs resort to inconvenient workarounds, such as installing a particle trap – via pressfit or other union and associated fittings – which can clog, or using in-line frits on the column at the valve or detector, which require periodic maintenance. Now, however, Agilent has developed a column technology with a built-in solution to the PLOT column particle shedding problem.The ONLY columns with integrated particle trapping technology on both ends – enabling worry-free operationOur integrated particle trapping technology – an Agilent exclusive – takes the worry out of performing GC or GC/MS analysis with PLOT columns for more confident day-to-day operation and identification of unknowns. Benefits include:• Enhanced analytical capability in the lab using PLOT analyses with MS detection and CFT devices.• No more hassles with unions or downstream filters: Our integrated particle trapping technology is incorporated into the column as one continuous length of fused silica tubing. • Higher throughput: Reproducible flow restriction and increased stability reduce the need for method/system adjustments, and promote a steadier analytical output.• Lower operating costs and less downtime associated with replacing filters and column switching valves. • Easy upgrade: No changes in selectivity means minimal method adjustments and method revalidation. The integrated particle trapping technology on both ends of Agilent J&W PLOT PT GC columns reduces downtime, while allowing you to use a GC/MS for detailed, qualitative and quantitative analysis. No other PLOT column offers this level of worry-free operation of your GC or GC/MS system.PROTECT YOuR GC SYSTEM fROM PLOT COLuMN PARTICLE SHEddINGAgilent J&W PLOT PT GC columnsNow you can confidently use PLOT columns for GC/MS applicationsAgilent J&W PLOT PT GC columns are the only PLOT columns stabilized with integrated particle trapping technology on both ends to virtually eliminate particle shedding. They are ideal for analyzing light gases, solvents, and other volatile organic compounds in hydrocarbon processing, environmental (air), forensic, and food applications. And they are brought to you by Agilent – the world’s GC leader.Ordering informationAgilent J&W PLOT PT columns are now available for porous polymer, alumina oxide, and MolSieve PLOT. If the column configuration you need is not mentioned here, it is also possible to order a custom column configuration in the Agilent J&W GC Custom Column Shop.For additional proof chromatograms, or to order now, visit agilent.com/chem/PLOTPTOr find your local Agilent Representative or Agilent Authorized Distributor at agilent.com/chem/contactus Part Number description dimensions* Part Number description dimensions*CP7348 PT PoraBOND Q PT 25 m x 0.25 mm x 3 µm CP7518 PT CP-Al2O3/KCl PT 50 m x 0.53 mm x 10 µmCP7351 PT PoraBOND Q PT 25 m x 0.32 mm x 5 µm 19091P-K15 PT HP-PLOT Al2O3 KCl PT 50 m x 0.32 mm x 8 µmCP7352 PT PoraBOND Q PT 50 m x 0.32 mm x 5 µm 19095P-K23 PT HP-PLOT Al2O3 KCl PT 30 m x 0.53 mm x 15 µmCP7353 PT PoraBOND Q PT 10 m x 0.53 mm x 10 µm 19095P-K25 PT HP-PLOT Al2O3 KCl PT 50 m x 0.53 mm x 15 µmCP7354 PT PoraBOND Q PT 25 m x 0.53 mm x 10 µm 115-3352 PT GS-Alumina/KCl PT 50 m x 0.53 mmCP7550 PT PoraPLOT Q PT 10 m x 0.32 mm x 10 µm CP7565 PT CP-Al2O3/Na2SO4 PT 50 m x 0.32 mm x 5 µmCP7551 PT PoraPLOT Q PT 25 m x 0.32 mm x 10 µm CP7568 PT CP-Al2O3/Na2SO4 PT 50 m x 0.53 mm x 10 µmCP7554 PT PoraPLOT Q PT 25 m x 0.53 mm x 20 µm 19091P-S12 PT HP-PLOT Al2O3 S PT 25 m x 0.32 mm x 8 µmCP7557 PT PoraPLOT Q-HT PT 25 m x 0.32 mm x 10 µm 19091P-S15 PT HP-PLOT Al2O3 S PT 50 m x 0.32 mm x 8 µm115-3432 PT GS-Q PT 30 m x 0.53 mm 19095P-S23 PT HP-PLOT Al2O3 S PT 30 m x 0.53 mm x 15 µm19091P-QO3 PT HP-PLOT Q PT 15 m x 0.32 mm x 20 µm 19095P-S25 PT HP-PLOT Al2O3 S PT 50 m x 0.53 mm x 15 µm19091P-QO4 PT HP-PLOT Q PT 30 m x 0.32 mm x 20 µm 115-3532 PT GS-Alumina PT 30 m x 0.53 mm19095P-QO3 PT HP-PLOT Q PT 15 m x 0.53 mm x 40 µm 115-3552 PT GS-Alumina PT 50 m x 0.53 mm19095P-QO4 PT HP-PLOT Q PT 30 m x 0.53 mm x 40 µm 19095P-M25 PT HP-PLOT Al2O3 M PT 50 m x 0.53 mm x 15 µmCP7584 PT PoraPLOT U PT 25 m x 0.53 mm x 20 µm CP7534 PT CP-Molsieve 5A PT 30 m x 0.32 mm x 10 µm19095P-UO4 PT HP-PLOT U PT 30 m x 0.53 mm x 20 µm CP7536 PT CP-Molsieve 5A PT 25 m x 0.32 mm x 30 µmCP7515 PT CP-Al2O3/KCl PT 50 m x 0.32 mm x 5 µm CP7538 PT CP-Molsieve 5A PT 25 m x 0.53 mm x 50 µmCP7517 PT CP-Al2O3/KCl PT 25 m x 0.53 mm x 10 µm CP7539 PT CP-Molsieve 5A PT 50 m x 0.53 mm x 50 µmThis information is subject to change without notice.© Agilent Technologies, Inc. 2013 Printed in the USA August 2, 20135991-1174EN2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00 18.00 20.00 22.00 24.00 26.00 28.00 1 2 3 4 5 6 7 6 4.80 5.00 5.20 5.40 5.60 5.80 6.00 6.20 6.40 6.60 6.80 7.00 7.20 5 7 8 9 10 11 8 9 10 11 12 13 16 14,15 17 18 20 19 21 22 23,24 25 26 27 28 29 30 31 32 33 * Paraldehyde Column: PoraBond Q PT 25 m × 0.25 mm Part No. CP7348PTCarrier : Helium, constant flow mode, 40 cm/s @ 90 °CInlet: 200 °C, split ratio 120:1OVEN: 90 °C, 10 °C/min to 140 °C for 6 min, 5 °C/min to 200 °C for 10 minMSD: 280 °C transfer line, full scan at m/z 30-350Integrated PLOT column particle trapping technology enables worry-free operation with mass selective detection. 1. Methanol 2. Acetaldehyde 3. Ethanol 4. Acetonitrile 5. Acetone 6. Methylene chloride 7. Isopropyl alcohol 8. 2-Propanamine 9. Ethyl formate 10. 1-Propanol 11. Ethyl ether 12. 2-Methyl-2-propanol 13. 1,2-Ethanediol 14. Trichloromethane 15. 2-Butanone 16. Ethyl acetate 17. 2-Methyl-1-propanol 18. MTBE 19. 2-Chloro-butane20. 1-Butanol 21. Benzene 22. 1,1,1-Trichloroethane 23. Carbon tetrachloride 24. 1-Chlorobutane 25. Hexane 26. 3-Methyl-1-butanol 27. DMSO 28. Toluene 29. Heptane 30. Ethylbenzene 31. 1,3-Dimethylbenzene 32. p-Xylene 33. o-Xylene * PLOT PT columns have 2.5 m of integrated particle traps on both ends which extend the stated length of the column by 5 meters.
Most popular related searches